• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MAX8830 LED Light Management IC in 2.5mm x 2.5mm UCSP General Description
MAX8830 LED Light Management IC in 2.5mm x 2.5mm UCSP General Description

... 100µA current source. During this time, the internal MOSFET is switching at the minimum duty cycle. Once VCOMP rises above 1V, the duty cycle increases until the output voltage reaches the desired regulation level. COMP is pulled to GND with a 80Ω internal resistor during UVLO or shutdown. See the T ...
What is Characteristic Impedance?
What is Characteristic Impedance?

... constant applied voltage. It you were to ask it, what sort of circuit element behaves this way- has a constant current draw for constant applied voltage, of course, it would say a resistor. To the battery, while the signal is moving down the transmission line, (emphasis added) charging up successive ...
Grid Code
Grid Code

... A connectee’s plants are, for the purpose of supplying or drawing electrical energy, connected via switching points with a disconnection function (circuit breakers and disconnectors). This connection points are defined by ENE, taking into account the prevailing grid conditions, the power and the way ...
Chapter Title
Chapter Title

Short-Circuit Generator Set for AICHI ELECTRIC CO., LTD.
Short-Circuit Generator Set for AICHI ELECTRIC CO., LTD.

Practical Simulation and Modelling of Lightning Impulse Voltage
Practical Simulation and Modelling of Lightning Impulse Voltage

... characteristics is desired. Power lines and equipment are revealed to the atmosphere, hence ...
IEEE 802.3at 高功率供电器件(PD) 接口带有外部栅极驱动器(Rev. A)
IEEE 802.3at 高功率供电器件(PD) 接口带有外部栅极驱动器(Rev. A)

... The CDB pin can inhibit downstream converter start up by keeping the soft start pin low. Figure 16 shows where the CDB connects to the SS pin of a UCC2897A DC-DC controller. Because CDB is an open drain output, it will not affect the soft start capacitor charge time when it deasserts. The CDB pin ca ...
An Active Decoupling Capacitance Circuit for Inductive Noise
An Active Decoupling Capacitance Circuit for Inductive Noise

600 Volt Automatic Transfer Switches
600 Volt Automatic Transfer Switches

... be designed with interlocks that prevent the inadvertent and indefinite paralleling of sources. The following design rules should be used when designing closed-transition system. 1. Closed-transition switchgear should be designed such that manual transfers are manually initiated and automatically in ...
Basics of Load Centers
Basics of Load Centers

Klystrons
Klystrons

... of the cavities. The BCD system uses a rectilinear distribution system with equal amounts of RF power being fed to each cavity through directional couplers. The circulators, along with the high power loads, protect the klystron from reflected power during the cavity filling time. The 3-stub tuners a ...
Micronta 22-204A range doubler multimeter instructions
Micronta 22-204A range doubler multimeter instructions

... CURRENT OR OHMS. Unlike most modern meters, the 22-204A does not have any internal fuses, you will burn resistors inside the meter if you put is across a power supply with it set to read current or resistance. Remove the back of the Multitester and install the batteries. Be careful to observe batter ...
A Recursive Switched-Capacitor DC-DC Converter Achieving Ratios
A Recursive Switched-Capacitor DC-DC Converter Achieving Ratios

Chapter 11 Shielded Metal Arc Welding Principles
Chapter 11 Shielded Metal Arc Welding Principles

... • DCEN (d.c. electrode negative) – Electrode connected to negative terminal of power source and work connected to positive terminal (current flows from neg to pos) flow from electrode to work = more electrode consumption. – 1/3 of heat on electrode. 2/3 on work – High electrical melting rate ...
INDIANA UNIVERSITY - PURDUE UNIVERSITY FORT WAYNE  DEPARTMENT OF ENGINEERING
INDIANA UNIVERSITY - PURDUE UNIVERSITY FORT WAYNE DEPARTMENT OF ENGINEERING

... Wayne Combustion Systems (WCS) builds burners for oven and furnace applications that require a control circuit to regulate the combustion fan and gas valve of the burner to maintain a desired temperature. The current control board is built and owned by another company, which increases the cost of th ...
Electrical Overstress EOS
Electrical Overstress EOS

... The damage caused by EOS is typically so extensive that the origin of the problem can not be determined. An initial small voltage perturbation can cascade into a large event and cause damage that overwhelms the original damage site. The analysis report will identify which package pins are damaged an ...
electrical safety general electrical safety
electrical safety general electrical safety

... Electricity has long been recognized as a serious workplace hazard. Many workers are unaware of the potential electrical hazards present in their work environment, which makes them more vulnerable to the danger of electrocution. OSHA's electrical standards are designed to protect employees exposed t ...
Aalborg Universitet Elektrisk miljø i svinestalde
Aalborg Universitet Elektrisk miljø i svinestalde

DT1452-02SO Features Mechanical Data
DT1452-02SO Features Mechanical Data

... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Bulletin CW-E Clamp-on Power Meters CW120,CW121,CW240
Bulletin CW-E Clamp-on Power Meters CW120,CW121,CW240

... 3. For energy investigation/control for privately-owned electrical power facilities 4. For control of monthly target energy consumption ...
[PDF]
[PDF]

Adam Equipment ADK PRECISION BALANCES
Adam Equipment ADK PRECISION BALANCES

... (5) If the zero value is too large (>350), unfasten the locking screws and move the counter-balance weight away from the core of the balance. In case of a too small zero value move the counter-balance towards the core. Fasten the screws after readjustment. (6) Turn back the sensor as normal. Put the ...
FJD5555 NPN Silicon Transistor — NPN Silicon T ransistor
FJD5555 NPN Silicon Transistor — NPN Silicon T ransistor

... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild's quality standards for handling and storage and provide access to Fairchild's ...
standard power products
standard power products

The Polarization Cell Replacement (PCR)
The Polarization Cell Replacement (PCR)

< 1 ... 197 198 199 200 201 202 203 204 205 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report