PDF
... Over recent years, wind energy has been considered as one of the most signicant renewable energy sources. Among the existing wind power generation systems, its generators can be categorized into four main types [1], [2]: 1) the doubly fed induction generator 2) the squirrel cage induction generator ...
... Over recent years, wind energy has been considered as one of the most signicant renewable energy sources. Among the existing wind power generation systems, its generators can be categorized into four main types [1], [2]: 1) the doubly fed induction generator 2) the squirrel cage induction generator ...
Power Rectifiers_updated - Georgia Institute of Technology
... function of rectifier circuit by using three-field notation of phases, ways, and number of pulses. – Single-phase, half-wave rectifier circuit is given somewhat cryptic designation of 1Ph1W1P (1 phase, 1 way, 1 pulse), meaning that AC supply voltage is single-phase, that current on each phase of AC ...
... function of rectifier circuit by using three-field notation of phases, ways, and number of pulses. – Single-phase, half-wave rectifier circuit is given somewhat cryptic designation of 1Ph1W1P (1 phase, 1 way, 1 pulse), meaning that AC supply voltage is single-phase, that current on each phase of AC ...
BP104, BP104S Silicon PIN Photodiode
... using a low resistance load (≤ 10 Ω) of such a value that the voltage dropped across is very much lower than the open circuit voltage produced under identical illumination conditions (Rmeas << Ri). The voltage across the load should be measured with a sensitive DVM. A knowledge of radiant intensity, ...
... using a low resistance load (≤ 10 Ω) of such a value that the voltage dropped across is very much lower than the open circuit voltage produced under identical illumination conditions (Rmeas << Ri). The voltage across the load should be measured with a sensitive DVM. A knowledge of radiant intensity, ...
MAX14984 Enhanced VGA Port Protector with Monitor General Description
... monitor is detected. A switched 5V output provides up to 55mA to the VGA port in addition to normal VGA signals. The MAX14984 features a single active-low enable input to control two 5V USB switches. Each switch supplies 500mA of current with less than 250mV drop from VCC, and is protected against s ...
... monitor is detected. A switched 5V output provides up to 55mA to the VGA port in addition to normal VGA signals. The MAX14984 features a single active-low enable input to control two 5V USB switches. Each switch supplies 500mA of current with less than 250mV drop from VCC, and is protected against s ...
AT04296: Low Power Features of SAM L Series Devices
... responsiveness with power consumption. A standard low power technique is to limit the amount of time a device spends in active mode by increasing the time spent in low power sleep modes. The features described in this application note allows the device to perform tasks, while active or in a sleep mo ...
... responsiveness with power consumption. A standard low power technique is to limit the amount of time a device spends in active mode by increasing the time spent in low power sleep modes. The features described in this application note allows the device to perform tasks, while active or in a sleep mo ...
TDA9103
... during the transient phase of VCC switching on, or switching off, the value of VCC is monitored and the outputs of the circuit are inhibited if it is too low. In order to have a very good powersupplyrejection, the circuit is internally powered by several internal voltage references (The unique typic ...
... during the transient phase of VCC switching on, or switching off, the value of VCC is monitored and the outputs of the circuit are inhibited if it is too low. In order to have a very good powersupplyrejection, the circuit is internally powered by several internal voltage references (The unique typic ...
5000V Megohmmeters Models 5000N/5100/5110
... • Tests are to be carried out only on non-energized circuits! Check for live circuits before making resistance measurements (safety check). • These Megohmmeters are sources of high voltage, as is the sample connected to them. All persons performing or assisting in the tests must employ all safety pr ...
... • Tests are to be carried out only on non-energized circuits! Check for live circuits before making resistance measurements (safety check). • These Megohmmeters are sources of high voltage, as is the sample connected to them. All persons performing or assisting in the tests must employ all safety pr ...
General Description Features
... µMAX® package. Operation at high frequency, compatibility with ceramic capacitors, and inverting topology without transformers allow for a compact design. Compatibility with electrolytic capacitors and flexibility to operate down to 100kHz allow users to minimize the cost of external components. The ...
... µMAX® package. Operation at high frequency, compatibility with ceramic capacitors, and inverting topology without transformers allow for a compact design. Compatibility with electrolytic capacitors and flexibility to operate down to 100kHz allow users to minimize the cost of external components. The ...
R0E330850ACBP0 User`s Manual
... z If the pins protected against overvoltage are overvoltaged, the voltage of the Vcc1 pin may rise up to 5.6 V because of reverse current. When you need to maintain the Vcc1 pin voltage of the user system, add dummy resistance and voltage regulator diode to the power line of the Vcc1. (Figure 3 is a ...
... z If the pins protected against overvoltage are overvoltaged, the voltage of the Vcc1 pin may rise up to 5.6 V because of reverse current. When you need to maintain the Vcc1 pin voltage of the user system, add dummy resistance and voltage regulator diode to the power line of the Vcc1. (Figure 3 is a ...
LT6236/LT6237 - Rail-to-Rail Output 215MHz, 1.1nV/√Hz Op Amp/SAR ADC Driver
... voltage density and draw only 3.5mA of supply current per amplifier. These amplifiers combine very low noise and supply current with a 215MHz gain bandwidth product and a 70V/μs slew rate. Low noise, fast settling time and low offset voltage make this amplifier optimal to drive low noise, high speed ...
... voltage density and draw only 3.5mA of supply current per amplifier. These amplifiers combine very low noise and supply current with a 215MHz gain bandwidth product and a 70V/μs slew rate. Low noise, fast settling time and low offset voltage make this amplifier optimal to drive low noise, high speed ...
TL1963A-Q1 数据资料 dataSheet 下载
... than 1 mA in shutdown. Quiescent current is well controlled; it does not rise in dropout as it does with many other regulators. In addition to fast transient response, the TL1963A regulators have very low output noise, which makes them ideal for sensitive RF supply applications. Output voltage range ...
... than 1 mA in shutdown. Quiescent current is well controlled; it does not rise in dropout as it does with many other regulators. In addition to fast transient response, the TL1963A regulators have very low output noise, which makes them ideal for sensitive RF supply applications. Output voltage range ...
BDTIC www.BDTIC.com/infineon ® Version 2.0, 11 Jan 2012
... voltage detect for the burst selection. It is particular good for high voltage margin low power SMPS application such as auxiliary power supply for PC and server. The major characteristics are that the IC is developed with 800V CoolMOS® with start up cell, having adjustable brownout feature, running ...
... voltage detect for the burst selection. It is particular good for high voltage margin low power SMPS application such as auxiliary power supply for PC and server. The major characteristics are that the IC is developed with 800V CoolMOS® with start up cell, having adjustable brownout feature, running ...
Paper Title (use style: paper title) - Scientific Bulletin of Electrical
... Electromagnetic torque changes which leads to the reduction of ASM efficiency; The appearance of some oscillations of torsion torque at the shaft of electrical machine; Changes of magnetic inductions in ASM air gap, due to high-order harmonics; Interactions between the fundamental harmonic m ...
... Electromagnetic torque changes which leads to the reduction of ASM efficiency; The appearance of some oscillations of torsion torque at the shaft of electrical machine; Changes of magnetic inductions in ASM air gap, due to high-order harmonics; Interactions between the fundamental harmonic m ...
MAX1845 Dual, High-Efficiency, Step-Down Controller with Accurate Current Limit General Description
... step-down (buck) topologies that provides high efficiency, excellent transient response, and high DC output accuracy necessary for stepping down high-voltage batteries to generate low-voltage chipset and RAM power supplies in notebook computers. The CS_ inputs can be used with low-side sense resisto ...
... step-down (buck) topologies that provides high efficiency, excellent transient response, and high DC output accuracy necessary for stepping down high-voltage batteries to generate low-voltage chipset and RAM power supplies in notebook computers. The CS_ inputs can be used with low-side sense resisto ...
GE MagneBlast Sample Specification
... different voltage, current, interrupting capacity or physical arrangement than the type intended for the switchgear cell receiving the breaker. The system shall match the existing system in the cell if it exists. 10 Design and Certification (Type) Testing In accordance with ANSI C37.59-1996, replace ...
... different voltage, current, interrupting capacity or physical arrangement than the type intended for the switchgear cell receiving the breaker. The system shall match the existing system in the cell if it exists. 10 Design and Certification (Type) Testing In accordance with ANSI C37.59-1996, replace ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... bring higher voltage parts of a circuit into direct electrical contact with parts that are normally at lower voltages, so in high-voltage circuits, a short can present a dangerous electrocution hazard. Fuses are therefore selected to allow passage of normal current plus a marginal percentage and to ...
... bring higher voltage parts of a circuit into direct electrical contact with parts that are normally at lower voltages, so in high-voltage circuits, a short can present a dangerous electrocution hazard. Fuses are therefore selected to allow passage of normal current plus a marginal percentage and to ...
Reliability Fundamentals of System Protection
... breaker) that quickly disconnects the affected elements. Protection systems are generally comprised of protective relays, communication systems necessary for correct operation of protective functions, voltage and current sensing inputs to protective relays and associated circuitry from the voltage a ...
... breaker) that quickly disconnects the affected elements. Protection systems are generally comprised of protective relays, communication systems necessary for correct operation of protective functions, voltage and current sensing inputs to protective relays and associated circuitry from the voltage a ...
AN203: 8-bit MCU Printed Circuit Board Design Notes
... In-series inductance provides the most effective isolation from high-frequency noise. The inductance should be placed between the analog and digital power supply circuits, with the analog circuit closest to the voltage regulator. If, due to cost or lack of availability, it is not practical to use an ...
... In-series inductance provides the most effective isolation from high-frequency noise. The inductance should be placed between the analog and digital power supply circuits, with the analog circuit closest to the voltage regulator. If, due to cost or lack of availability, it is not practical to use an ...
Extended Product Overview - AMETEK Programmable Power
... company’s operations and in certain areas has dedicated focus activities, such as the Solutions Group. The organization chart shown represents the Senior Management of the company. The nature of the Solutions business involves a high degree of project management involvement with dedicated program ma ...
... company’s operations and in certain areas has dedicated focus activities, such as the Solutions Group. The organization chart shown represents the Senior Management of the company. The nature of the Solutions business involves a high degree of project management involvement with dedicated program ma ...
DT2636-04S Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.