• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
BD00GA5WEFJ
BD00GA5WEFJ

Appendix D-4  Electrical Advanced-Level Training Issue Date:  12/29/11
Appendix D-4 Electrical Advanced-Level Training Issue Date: 12/29/11

... A standard may be defined as a document that applies collectively to codes, specifications, recommended practices, test methods, and guides, which have been prepared by a standards developing organization or group, and published in accordance with established procedures. Standards promote safety, re ...
µPMICs for Multimedia Application Processors in a 3.0mm x 2.5mm WLP MAX8893A/MAX8893B/MAX8893C
µPMICs for Multimedia Application Processors in a 3.0mm x 2.5mm WLP MAX8893A/MAX8893B/MAX8893C

... programmable output voltages, individual power-on/ off control inputs, a load switch, and a USB high-speed switch. These devices maintain high efficiency with a low no-load supply current, and the small 3.0mm x 2.5mm WLP package makes them ideal for portable devices. ...
Instructions - Howard Transformers
Instructions - Howard Transformers

Power Electronic - NED University of Engineering and Technology
Power Electronic - NED University of Engineering and Technology

Introduction - Electrical and Computer Engineering
Introduction - Electrical and Computer Engineering

... Time-varying currents and voltages resulting from sudden application of sources, usually due to switching ...
LT5546
LT5546

... a 10dB signal-to-noise ratio. In the case of an L-C matching circuit, the circuit of Figure 1 can be used. In Table 1 the matching network component values are given for a range of IF frequencies. The matching circuit of Figure 1 approaches 180° phase shift between IF+ and IF– in a broad range aroun ...
Complete Paper
Complete Paper

... Abstract—Power and area will remain the main constraints in the designing of VLSI circuits. Dynamic CMOS logic circuits are broadly designed for high performance circuits due to their high speed. Conversely, the demerit of dynamic logic style is its high noise sensitivity. The main cause of this is ...
10 Things to Consider in a POL Module | CUI Inc
10 Things to Consider in a POL Module | CUI Inc

... typically expressed in watts per cubic inch (W/in3) or watts per cubic centimeter (W/cm3). Today’s ever-more complex systems that require more power in the same or smaller space will seek out POL modules with higher power densities. ...
280-20
280-20

... Types D and DV single-phase automatic circuit reclosers from Eaton’s Cooper Power Systems provide reliable, economical overcurrent protection for distribution systems. Designed for 15 kV (Type D) and 15-34.5 kV (Type DV) system applications such as sectionalizing single-phase branches of three-phase ...
2005 Residential Wireman Renewal Exam #1
2005 Residential Wireman Renewal Exam #1

... Fire pump supply conductors on the load side of the final disconnecting means and overcurrent device(s) are permitted to be routed through a building if: a. Encased in at least 2” of brick. b. Installed in conduits or raceways with lighting and power conductors. c. Concealed within walls, floors, or ...
VISHAY IL256 datasheet
VISHAY IL256 datasheet

abstarct - The University of Texas at Dallas
abstarct - The University of Texas at Dallas

A  Global  Maximum  Power  Point ... Converter Joseph  Duncan
A Global Maximum Power Point ... Converter Joseph Duncan

J.M. Rivas, Y. Han, O. Leitermann, A.D. Sagneri, and D.J. Perreault, A High-Frequency Resonant Inverter Topology with Low Voltage Stress,” IEEE Transactions on Power Electronics , Vol. 23, No. 4, pp. 1759-1771, July 2008.
J.M. Rivas, Y. Han, O. Leitermann, A.D. Sagneri, and D.J. Perreault, A High-Frequency Resonant Inverter Topology with Low Voltage Stress,” IEEE Transactions on Power Electronics , Vol. 23, No. 4, pp. 1759-1771, July 2008.

... others) incorporate resonant networks in order to achieve efficient operation at very high frequencies and to meet other requirements. For example, the well-known class E inverter [10] uses resonant operation to provide zero-voltage switching and enable the use of (relatively) slow gating waveforms. ...
FAN25800 500 mA, Low-I , Low-Noise, LDO Regulator
FAN25800 500 mA, Low-I , Low-Noise, LDO Regulator

... The FAN25800 is a linear low-dropout (LDO) regulator that has high PSRR and low output noise. The enable control pin can be used to shut down the device and disconnect the output load from the input. During shutdown, the supply current drops below 1 µA. The LDO is designed to be stable with space-s ...
MULTIPLE RS-232 DRIVERS AND RECEIVERS
MULTIPLE RS-232 DRIVERS AND RECEIVERS

... Package thermal impedance, θJA (see Note 2): DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115°C/W DW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67°C/W ...
switches - (HOCL)
switches - (HOCL)

... 5. There should not be a failure of DC supply at load bus in the event of mains failure during boost charging or float charging. This shall be ensured by suitable DC link between battery and load. 6. Soft start feature shall be provide in the charger so that when the charger is switched ON, the outp ...
Photocontrol Surge Protection 1. ALL ABOUT MOVS 1.1 What is a
Photocontrol Surge Protection 1. ALL ABOUT MOVS 1.1 What is a

... Joules. A joule equals a watt-second. This is the amount of energy that a MOV can absorb without changing its characteristics. Since a MOV works by converting surge energy into heat energy, physically larger MOVs generally have a higher joule rating. DTL offers several levels of surge protection inc ...
The Transfrormer
The Transfrormer

... Windings on transformers or other electrical machines are marked to indicate terminals of like polarity. Consider the two windings shown in Fig.3.7a. Terminals 1 and 3 are identical, because currents entering these terminals produce fluxes in the same direction in the core that forms the common magn ...
Transfrormer_Handouts
Transfrormer_Handouts

... Windings on transformers or other electrical machines are marked to indicate terminals of like polarity. Consider the two windings shown in Fig.3.7a. Terminals 1 and 3 are identical, because currents entering these terminals produce fluxes in the same direction in the core that forms the common magn ...
Product Range 2014 Portable Reference Meters
Product Range 2014 Portable Reference Meters

BUF11705 22-V Supply, 10+1 Channel Gamma Correction Buffer FEATURES
BUF11705 22-V Supply, 10+1 Channel Gamma Correction Buffer FEATURES

... and BUF11704 and operates at higher supply voltages up to 22 V (24 V absolute max). The higher supply voltage enables faster response times and brighter images in large-screen LCD panels. This is especially important in LCD TV applications. The BUF11705 offers 10 gamma channels. For additional space ...
AL5811 Description Pin Assignments
AL5811 Description Pin Assignments

... Semiconductor devices are ESD sensitive and may be damaged by exposure to ESD events. Suitable ESD precautions should be taken when handling and transporting these devices ...
Blocking Oscillation Due to Combination of Discrete and Continuous
Blocking Oscillation Due to Combination of Discrete and Continuous

... It can be seen in Figures 2 and 3 that the signals from the blocking oscillators are rather small and fast. The RF-SET technique [6] and the Josephson sampling technique [13, 14] would be applied to detect such signals, although each of them is a challenging task. Here, the author proposes an indire ...
< 1 ... 193 194 195 196 197 198 199 200 201 ... 1160 >

Electrical substation



A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report