ISL9R860PF2 8 A, 600 V, STEALTH Diode —
... performance in high frequency hard switched applications. The STEALTH™ family exhibits low reverse recovery current (Irr) and exceptionally soft recovery under typical operating conditions. This device is intended for use as a free wheeling or boost diode in power supplies and other power switching ...
... performance in high frequency hard switched applications. The STEALTH™ family exhibits low reverse recovery current (Irr) and exceptionally soft recovery under typical operating conditions. This device is intended for use as a free wheeling or boost diode in power supplies and other power switching ...
NCP5392Q - 2/3/4-Phase Controller for CPU Applications
... providing the fastest initial response to dynamic load events. Dual--edge multiphase modulation reduces the total bulk and ceramic output capacitance required to meet transient regulation specifications. A high performance operational error amplifier is provided to simplify compensation of the syste ...
... providing the fastest initial response to dynamic load events. Dual--edge multiphase modulation reduces the total bulk and ceramic output capacitance required to meet transient regulation specifications. A high performance operational error amplifier is provided to simplify compensation of the syste ...
P84601
... including audible signaling appliances, powered by the same source and include any required safety factors. If the peak current exceeds the power supplies’ peak capacity, the output voltage provided by the power supplies may drop below the listed voltage range of the appliances connected to the supp ...
... including audible signaling appliances, powered by the same source and include any required safety factors. If the peak current exceeds the power supplies’ peak capacity, the output voltage provided by the power supplies may drop below the listed voltage range of the appliances connected to the supp ...
motors for copeland™ semi-hermetic compressors
... Part-winding start motors contain two separate windings (2/3:1/3) which are internally connected in star and operated in parallel. One cannot change the voltage by changing the electrical connections as the motor is only suitable for one voltage range (see Table 1). The first part winding (2/3) on t ...
... Part-winding start motors contain two separate windings (2/3:1/3) which are internally connected in star and operated in parallel. One cannot change the voltage by changing the electrical connections as the motor is only suitable for one voltage range (see Table 1). The first part winding (2/3) on t ...
The Numerical Modeling of Transient Regimes of Diesel Generator
... Using a data acquisition card, we stored the time evolution of the output current and voltage produced by the generator set after applying a resistive load at the generator terminals. At the beginning, the diesel generator set was operating in no-load regime, the load current being null, the generat ...
... Using a data acquisition card, we stored the time evolution of the output current and voltage produced by the generator set after applying a resistive load at the generator terminals. At the beginning, the diesel generator set was operating in no-load regime, the load current being null, the generat ...
CB-845X - BiddleMegger.com
... Every consideration has been given to the design and construction of the Model CB845X Test Set to make it a safe piece of test equipment as well as one that is accurate, reliable, and easy to use. It must be remembered that the unit is capable of producing high voltage and current levels that can be ...
... Every consideration has been given to the design and construction of the Model CB845X Test Set to make it a safe piece of test equipment as well as one that is accurate, reliable, and easy to use. It must be remembered that the unit is capable of producing high voltage and current levels that can be ...
Fault Location Of Overhead Transmission Line.pdf
... The fault location is then determined by timing analysis of the travelling wave. As the faulted signal obtained at the end of the transmission line is highly mingled with noise, some modern signal processing techniques, such as the wavelet are used for fault location. In the traveling-wave based app ...
... The fault location is then determined by timing analysis of the travelling wave. As the faulted signal obtained at the end of the transmission line is highly mingled with noise, some modern signal processing techniques, such as the wavelet are used for fault location. In the traveling-wave based app ...
Schneider Electric Catalog
... 120 VAC input, without the need for an external transformer. For expanded off-grid capacity, the Conext SW is integrated with fuel-based generators as required to support loads larger than the generator’s output. It’s also self consumption ready, able to prioritize solar consumption over the grid, w ...
... 120 VAC input, without the need for an external transformer. For expanded off-grid capacity, the Conext SW is integrated with fuel-based generators as required to support loads larger than the generator’s output. It’s also self consumption ready, able to prioritize solar consumption over the grid, w ...
Optimum DC-Link Solution in HVDC Wind Park Actively
... impedance is big enough. For grid connections with lower reactance of the source impedance, as is often the case in distribution cables, the voltage level is not sensitive to changes in reactive power, but more depending on the active power flow [18]. If actively controlled, HVDC wind parks will be ...
... impedance is big enough. For grid connections with lower reactance of the source impedance, as is often the case in distribution cables, the voltage level is not sensitive to changes in reactive power, but more depending on the active power flow [18]. If actively controlled, HVDC wind parks will be ...
WARNING! - AR - RF Microwave Instrumentation
... output is connected to the input of the solid-state driver. The driver amp’s output is split by a 180° hybrid. Each of the hybrid’s secondaries is connected to the RF input of a TWT. The TWTs’ outputs are connected by coax to the input ports of a magic tee (waveguide 180° hybrid) (E20391). The magic ...
... output is connected to the input of the solid-state driver. The driver amp’s output is split by a 180° hybrid. Each of the hybrid’s secondaries is connected to the RF input of a TWT. The TWTs’ outputs are connected by coax to the input ports of a magic tee (waveguide 180° hybrid) (E20391). The magic ...
04_ELC4345_Fall2013_DC_DC_Buck_PPT
... • Occurs for light loads, or low operating frequencies, where the inductor current eventually hits zero during the switchopen state • The diode opens to prevent backward current flow ...
... • Occurs for light loads, or low operating frequencies, where the inductor current eventually hits zero during the switchopen state • The diode opens to prevent backward current flow ...
OPA379 OPA2379 OPA4379
... The OPA379 family of operational amplifiers minimizes power consumption without compromising bandwidth or noise. Power-supply rejection ratio (PSRR), common-mode rejection ratio (CMRR), and open-loop gain (AOL) typical values are 100dB or better. When designing for ultra-low power, choose system com ...
... The OPA379 family of operational amplifiers minimizes power consumption without compromising bandwidth or noise. Power-supply rejection ratio (PSRR), common-mode rejection ratio (CMRR), and open-loop gain (AOL) typical values are 100dB or better. When designing for ultra-low power, choose system com ...
Megger PULSAR Equipment Specifications
... LINE SYNCHRONIZATION: PULSAR was designed to be completely independent of the line voltage and frequency. However, there may be applications where synchronizing to the line frequency may be desirable. With Line Synchronization activated, the output voltages and currents will be in phase with the inp ...
... LINE SYNCHRONIZATION: PULSAR was designed to be completely independent of the line voltage and frequency. However, there may be applications where synchronizing to the line frequency may be desirable. With Line Synchronization activated, the output voltages and currents will be in phase with the inp ...
TPS548B22 1.5-V to 18-V VIN, 4.5-V to 22-V VDD, 25
... The TPS548B22 device is a compact single buck converter with adaptive on-time, D-CAP3 mode control. It is designed for high accuracy, high efficiency, fast transient response, ease-of-use, low external component count and space-conscious power systems. This device features full differential sense, T ...
... The TPS548B22 device is a compact single buck converter with adaptive on-time, D-CAP3 mode control. It is designed for high accuracy, high efficiency, fast transient response, ease-of-use, low external component count and space-conscious power systems. This device features full differential sense, T ...
a 4/8 Channel Fault-Protected Analog Multiplexers ADG508F/ADG509F/ADG528F*
... single channels and the ADG509F comprising four differential channels. These multiplexers provide fault protection. Using a series n-channel, p-channel, n-channel MOSFET structure, both device and signal source protection is provided in the event of an overvoltage or power loss. The multiplexer can ...
... single channels and the ADG509F comprising four differential channels. These multiplexers provide fault protection. Using a series n-channel, p-channel, n-channel MOSFET structure, both device and signal source protection is provided in the event of an overvoltage or power loss. The multiplexer can ...
DLT100AGEVB ON Semiconductor Dynamic Load Tool Evaluation Board User's Quick Step Guide
... The dynamic load tool is equipped with two load range settings (High & Low) The high load range offers the ability to load more power (Typically ~55 W total) and has a current monitor resolution of 5 mV/A. The low load range has a lower loading power ability (Typically ~12 W total), but has a higher ...
... The dynamic load tool is equipped with two load range settings (High & Low) The high load range offers the ability to load more power (Typically ~55 W total) and has a current monitor resolution of 5 mV/A. The low load range has a lower loading power ability (Typically ~12 W total), but has a higher ...
User GUide
... a risk of fire, electric shock, or injury to persons. 6) Do not disassemble the IntelliSUPPLY. Attempting to service the unit yourself may result in a risk of electrical shock or fire. Internal capacitors remain charged after all power is disconnected. 7) Do not open the IntelliSUPPLY. There are n ...
... a risk of fire, electric shock, or injury to persons. 6) Do not disassemble the IntelliSUPPLY. Attempting to service the unit yourself may result in a risk of electrical shock or fire. Internal capacitors remain charged after all power is disconnected. 7) Do not open the IntelliSUPPLY. There are n ...
ZRC500
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
ISO Rules Part 500 Facilities Division 502 Technical Requirements
... (2) The legal owner of a generating unit must determine the root mean square phase-to-phase voltage value at the transmission system step-up transformer of the generating unit to be used as the one hundred percent (100%) voltage value to determine the voltage ride through requirements for the genera ...
... (2) The legal owner of a generating unit must determine the root mean square phase-to-phase voltage value at the transmission system step-up transformer of the generating unit to be used as the one hundred percent (100%) voltage value to determine the voltage ride through requirements for the genera ...
Electrical substation
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.Substations may be owned and operated by an electrical utility, or may be owned by a large industrial or commercial customer. Generally substations are unattended, relying on SCADA for remote supervision and control.A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. The word substation comes from the days before the distribution system became a grid. As central generation stations became larger, smaller generating plants were converted to distribution stations, receiving their energy supply from a larger plant instead of using their own generators. The first substations were connected to only one power station, where the generators were housed, and were subsidiaries of that power station.