• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
40 V to 400 V Uni-directional Current/Voltage/Power Monitoring
40 V to 400 V Uni-directional Current/Voltage/Power Monitoring

... The OPA333 series of CMOS operational amplifiers use a proprietary auto-calibration technique to simultaneously provide very low offset voltage (10 μV, max) and near-zero drift over time and temperature. These miniature, high-precision, low quiescent current amplifiers offer high-impedance inputs th ...
Experiment 7: RC Circuits
Experiment 7: RC Circuits

... Figure 2: Potential difference across a capacitor in an RC circuit as a function of time. Part 1 - Measurement of a Long Time Constant: In this experiment, you will measure V(t) across the capacitor as it discharges. First measure the capacitance of the large capacitor provided using a capacitance m ...
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS 1
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS 1

... coefficient and load. However PP compensation topology was adopted in their work because parallel compensated transmitter could provide a large current and parallel compensated receiver had the current source characteristic which was more suitable for battery charging. This is correct when the syste ...
2012 IC******(C*)
2012 IC******(C*)

... 2. Please be noted: Use 3.3-V devices for all designs. Anyone who violates this requirement will be disqualified during the grading. 3. Supply voltage (VDD) is 1.8V and no negative bias source is allowed in your design. 4. Input clock signal is 50KHz with 50% duty cycle and 1.8V peak voltage (please ...
LM22679 - Texas Instruments
LM22679 - Texas Instruments

Rigorous Analysis of Traveling Wave Photodetectors under High
Rigorous Analysis of Traveling Wave Photodetectors under High

... photodetector, the photo generated carriers will increase the conductivity of the intrinsic region. Therefore, the propagation parameters of the microwave signal will change as well. Fig. 3 shows the propagation parameters of the microwave signal for different levels of the optical power. Both, the ...
EE 742 Chap. 5: Electromechanical Dynamics
EE 742 Chap. 5: Electromechanical Dynamics

... winding , the rotor flux linkage changes with time). • To simplify the analysis, only the salient pole machine is considered (i.e., ...
ILX485
ILX485

... Excessive output current and power dissipation caused by faults or by bus contention are prevented by two mechanisms. A foldback current limit on the output stage provides immediate protection against short circuits over the whole common-mode voltage range. In addition, a thermal shutdown circuit fo ...
AD8510
AD8510

... The AD8510/AD8512/AD8513 are single-, dual-, and quadprecision JFET amplifiers that feature low offset voltage, input bias current, input voltage noise, and input current noise. The combination of low offsets, low noise, and very low input bias currents makes these amplifiers especially suitable for ...
A Solid State Opening Switch and Mod Anode Supply for the
A Solid State Opening Switch and Mod Anode Supply for the

... power-supply system planned for APS. Specifications for the complete system are listed in Table 1. The opening switch for APS is complete, and is currently under test at DTI. The unit contains both the switch and the mod anode voltage regulation, and is approximately the size and configuration of th ...
BZ1A5001GM
BZ1A5001GM

... ROHM designs and manufactures its Products subject to strict quality control system. However, semiconductor products can fail or malfunction at a certain rate. Please be sure to implement, at your own responsibilities, adequate safety measures including but not limited to fail-safe design against th ...
TSM931 - Silicon Labs
TSM931 - Silicon Labs

Short Circuit Current Calculations
Short Circuit Current Calculations

... Normally, short circuit studies involve calculating a bolted 3-phase fault condition. This can be characterized as all 3-phases “bolted” together to create a zero impedance connection. This establishes a “worst case” (highest current) condition that results in maximum three phase thermal and mechani ...
IC 555 TIMER
IC 555 TIMER

SIDACtor Device
SIDACtor Device

... Communications equipment can be subjected to over voltage surges, over current surges or both. Over voltages destroy sensitive semiconductors in microprocessor based PBX/KSU systems, as well as CPU's in PC's or workstations. Over current events can generate enough heat to cause a building wiring fir ...
Measuring Class-D Amplifiers
Measuring Class-D Amplifiers

2SK3018
2SK3018

... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
J. Lu, D.J. Perreault and K.L. Afridi, “Impedance Control Network Resonant Converter for Wide-Range High-Efficiency Operation,” 2015 IEEE Applied Power Electronics Conference , pp. 1440-1447, March 2015.
J. Lu, D.J. Perreault and K.L. Afridi, “Impedance Control Network Resonant Converter for Wide-Range High-Efficiency Operation,” 2015 IEEE Applied Power Electronics Conference , pp. 1440-1447, March 2015.

... inverter leg lose ZVS turn-on capability. These factors result in extra losses and lead to lower converter efficiency at partial loads, and consequently to poor design tradeoffs. Other fixed frequency control techniques have also been developed [5], [6]. However, these also lose zero voltage switchi ...
Design of Analog Circuits in 28nm CMOS Technology for Physics
Design of Analog Circuits in 28nm CMOS Technology for Physics

... improve further, but many new challenges have been introduced for analog designers. In fact, for the digital circuits CMOS scaling-down leads to several benefits: speed improvement, reduced power consumption, high integration and complexity level. The analog circuits, instead, strongly suffers from ...
Resistors - Audiodiyers HU
Resistors - Audiodiyers HU

... Glass Capacitors • Glass is among the most stable and inert of dielectrics – Typical values available up to about 2 nF – Extremely stable, almost no aging, near zero voltage coefficient – Some sensitivity to frequency, perhaps a bit worse than “NP0” ceramics and polypropylene (PP) film capacitors—m ...
Power meters - OPS Schneider Electric
Power meters - OPS Schneider Electric

... * kW, kVAR, kWh, and kVARh are signed net consumption values. The PM750 keeps a single registers with the net consumption values per each type of Energy and Power. C. Demand All power demand calculations shall use any one of the following calculation methods, selectable by the user: 1) Block Interva ...
Power Supply - Fresh Nelly
Power Supply - Fresh Nelly

FSQ0465RS/RB Green-Mode Fairchild Power Switch (FPS™) for Quasi-Resonant Operation -
FSQ0465RS/RB Green-Mode Fairchild Power Switch (FPS™) for Quasi-Resonant Operation -

... switching frequency. The FSQ-series is an integrated Pulse-Width Modulation (PWM) controller and SenseFET specifically designed for quasi-resonant operation and Alternating Valley Switching (AVS). The PWM controller includes an integrated fixed-frequency oscillator, Under-Voltage Lockout (UVLO), Lea ...
Meba Main switch NC100H 1P 127.26 kB
Meba Main switch NC100H 1P 127.26 kB

... Features and Applications: NC100H mini circuit breaker, mcb Character: high breaker capacity up to 10KA 40-100A current avaliable Poles: 1P, 2P, 3P, 4P. NC100H high breaking capaci ty circuit breaker is used for AC 50Hz or 60Hz, single pole 240V, 2, 3, 4 Poles 415, for protecting the circuit that ov ...
Capacitor Transient Analysis
Capacitor Transient Analysis

< 1 ... 577 578 579 580 581 582 583 584 585 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report