• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
LAB MANUAL “Transient Current Technique – A Dynamic
LAB MANUAL “Transient Current Technique – A Dynamic

... Particle detectors are devices, or instruments that can detect track, momentum, energy, etc. of the incident particles. There are 3 types of detectors: solid, liquid, gas. Our study is focused on solid semiconductor silicon detectors because of various advantages over liquid and gaseous detectors. T ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

EnFilm™ micro-battery EFL700A39 user guide
EnFilm™ micro-battery EFL700A39 user guide

... a threshold voltage higher than 3.0 V - has to be put in place using a battery management IC such as ST SPV1050 device. These ICs must have a very low leakage current drawn from the battery specifically when the battery is disconnected. The Table 1 provides some example of allowable elapse time in b ...
Beat RFI! - Model Sounds Inc.
Beat RFI! - Model Sounds Inc.

... electronic devices and, as such, can also generate RFI if not well separated from the receiver antenna. Brushed motors generate RFI by two mechanisms. When the commutator switches current to the armature windings, sharp current spikes in the supply wires are created, and also the commutator arcing r ...
Elgar GUPS Series 2400 VA 115/230 VAC 20.8 ARMS
Elgar GUPS Series 2400 VA 115/230 VAC 20.8 ARMS

... supplied by the online inverter; the output is never dependent on the condition of the AC input, and there are no switching transients. Low output impedance allows driving non-linear loads that draw currents with high crest factors, such as computer power supplies. The 200% overload rating of the in ...
to full program of the technical sessions as a PDF file
to full program of the technical sessions as a PDF file

... RELATED TO HVDC and CONVERTER BASED Thursday 28th May (13.30 - 15.15) TECHNOLOGIES ...
Brochure PA004-1309 PDF 2.8MB - Transformer inrush current limiter
Brochure PA004-1309 PDF 2.8MB - Transformer inrush current limiter

... inrush-current phenomena would be inevitably caused. In contrast, if reasonable timing control of the HV-side breaker closing operation is conducted in order to minimize the fluxes differences ΔΦa, ΔΦb, ΔΦc, inrush current phenomena can be effectively restrained. Fig. 4-1 shows test data conducted i ...
Electrical Machines lab –II Manual
Electrical Machines lab –II Manual

OPA336-EP SINGLE-SUPPLY MICRO-POWER CMOS OPERATIONAL AMPLIFIER MicroAmplifier™ SERIES FEATURES
OPA336-EP SINGLE-SUPPLY MICRO-POWER CMOS OPERATIONAL AMPLIFIER MicroAmplifier™ SERIES FEATURES

... applications. The device operates on a single supply, with operation as low as 2.1 V. The output is rail to rail and swings to within 3 mV of the supplies with a 100-kΩ load. The common-mode range extends to the negative supply — ideal for single-supply applications. In addition to small size and lo ...
Types of resistors
Types of resistors

... same vertical line are connected to each other, i.e., horizontally adjacent holes are not connected to each other. The two wide superstrips, which have five horizontal sets of holes, are connected such that all holes lying on the same horizontal line are connected to each other, i.e., vertically adj ...
AN3193
AN3193

... become significant for a low operating frequency: at 1 MHz, each instruction lasts as long as the ADC conversion itself. When the ADC operates at such a low frequency, the conversion time is also significantly increased without benefits for the end application. To reduce the consumption and allow th ...
Type DTH 31, 32 DTTM 11, 12 High Speed Biased Differential Relays
Type DTH 31, 32 DTTM 11, 12 High Speed Biased Differential Relays

... ensures the secondary currents flowing in the interconnecting pilots are balanced and matched with the ...
Inverter Performance Test Protocal
Inverter Performance Test Protocal

... communications facilities or only a simple electric power feeder. Inverter: A machine, device, or system that changes direct-current power to alternating-current power. For the purposes of this test procedure, the inverter includes any input conversion (i.e., dc-dc chopper) that is included in the i ...
ADC10321 ADC10321 10-Bit, 20MSPS, 98mW A/D Converter with Internal Sample and... Literature Number: SNAS028E
ADC10321 ADC10321 10-Bit, 20MSPS, 98mW A/D Converter with Internal Sample and... Literature Number: SNAS028E

... 50mA maximum package input current rating limits the number of pins that can safely exceed the power supplies with an input current of 25mA to two. Note 4: The absolute maximum junction temperature (TJmax) for this device is 150˚C. The maximum allowable power dissipation is dictated by TJmax, the ju ...
Title : Feasible Performance Evaluations of Digitally
Title : Feasible Performance Evaluations of Digitally

... the need for large number of isolated DC sources. One way to ease this problem is to have the highest voltage stage, also referred to by the main stage, constructed with a topology that uses one DC supply for the three phase branches instead of the three full bridge cells. Constructing multistage in ...
A tuR  ochEF spEED coo   ovEn
A tuR ochEF spEED coo ovEn

... FRENCH FRIES (2 lbs., frozen) 5:30 Tabletop Impingement Conveyor 2:00 High h Batch ...
Design for Reliability in Power Electronics in IEEE Member
Design for Reliability in Power Electronics in IEEE Member

Aalborg Universitet Mostaan, Ali; N. Soltani, Mohsen
Aalborg Universitet Mostaan, Ali; N. Soltani, Mohsen

RMR 50 480 - Acuity Brands
RMR 50 480 - Acuity Brands

... unique sensor is line powered and enables direct switching of 480 VAC lighting loads. Designed to recess mount into a linear high bay fluorescent fixture using standard 4” x 4” junction box spacing, this sensor’s view pattern covers the area lit by three typically spaced T-5 or T-8 fixtures used in ...
Induction Machine Speed Control
Induction Machine Speed Control

Manual - CNCRoom
Manual - CNCRoom

... to Appendix III, the components overlay. If there is no step pulse comes to idler more than setup time, the idler will output idle single to drive circuit to reduce drive current. These 4 diodes allow user to choose which signal would influence the idler. Warning! In idle state, all step inputs must ...
Part II - Indian Navy
Part II - Indian Navy

analysis of a dual buck converter fed four-quadrant dc drive
analysis of a dual buck converter fed four-quadrant dc drive

... (IPQC’s). In this paper the performance of the separately excited dc machine fed by a single-phase, symmetrical multipulse modulated, improved power quality, dual AC-DC buck converter is investigated from the power quality in each quadrant of operation. The Symmetrical Multi pulse Modulation (SMM) t ...
ECE 310 - Course Website Directory
ECE 310 - Course Website Directory

... phase angle across the transformer Since power flow through the transformer depends upon phase angle, this allows the transformer to regulate the power flow through the transformer Phase shifters can be used to prevent inadvertent "loop flow" and to prevent line overloads. ...
AP65500 Description Pin Assignments
AP65500 Description Pin Assignments

... The AP65500 has on-chip thermal protection that prevents damage to the IC when the die temperature exceeds safe margins. It implements a thermal sensing to monitor the operating junction temperature of the IC. Once the die temperature rises to approximately +160°C, the thermal protection feature get ...
< 1 ... 581 582 583 584 585 586 587 588 589 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report