ZXTN04120HK Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
The Diode
... The directionality of current flow most diodes exhibit is sometimes generically called the rectifying property. The most common function of a diode is to allow an electric current to pass in one direction (called the forward biased condition) and to block it in the opposite direction (the reverse ...
... The directionality of current flow most diodes exhibit is sometimes generically called the rectifying property. The most common function of a diode is to allow an electric current to pass in one direction (called the forward biased condition) and to block it in the opposite direction (the reverse ...
Lower Power Synthesis - VADA
... product which removes the effect of frequency (delay) on power dissipation, a clear improvement is obtained in the form of an absolute lower number of transitions. It is also relatively easy to pipeline the bus activity. The extra pipeline stage and the extra latency must then be considered. The inc ...
... product which removes the effect of frequency (delay) on power dissipation, a clear improvement is obtained in the form of an absolute lower number of transitions. It is also relatively easy to pipeline the bus activity. The extra pipeline stage and the extra latency must then be considered. The inc ...
International Electrical Engineering Journal (IEEJ) Vol. 7 (2016) No.3, pp. 2196-2203
... Controlled synchronized closing of circuit breakers. Protective devices, such as surge arresters. The current work focuses on the overvoltages occurring upon the energization of no loaded transmission lines since these are considered to be the most dangerous case [11]. The statistical distributi ...
... Controlled synchronized closing of circuit breakers. Protective devices, such as surge arresters. The current work focuses on the overvoltages occurring upon the energization of no loaded transmission lines since these are considered to be the most dangerous case [11]. The statistical distributi ...
oscilloscope instruction manual
... WARNIN G Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must often be performed where exposed high voltage is present. An electrical shock causing 10 milliamps of current to pass through the heart will stop most human heartbeats. Voltage ...
... WARNIN G Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must often be performed where exposed high voltage is present. An electrical shock causing 10 milliamps of current to pass through the heart will stop most human heartbeats. Voltage ...
MS Series Owner`s Manual
... Use insulated tools to reduce the chance of electrical shock or accidental short circuits. There are no user-serviceable parts contained in this product. This unit is provided with integral protection against overloads. Live power may be present at more than one point since an inverter utilizes both ...
... Use insulated tools to reduce the chance of electrical shock or accidental short circuits. There are no user-serviceable parts contained in this product. This unit is provided with integral protection against overloads. Live power may be present at more than one point since an inverter utilizes both ...
power cApAciTors
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
... Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vi ...
14 Power Factor Correction
... be the control of the PF. This will be offset against the increase in space required for more capacitors and the cost for additional contactors. The only variation to this is for fixed duty loads (e.g. particular motor) where a single PFC step used in conjunction with the equipment is justified or m ...
... be the control of the PF. This will be offset against the increase in space required for more capacitors and the cost for additional contactors. The only variation to this is for fixed duty loads (e.g. particular motor) where a single PFC step used in conjunction with the equipment is justified or m ...
vialox® nav® vialox® nav
... • Existing installations: Higher lighting levels for the same energy costs. • New installations: Lower investment and operating costs thanks to smaller number of luminaires and lamps. ...
... • Existing installations: Higher lighting levels for the same energy costs. • New installations: Lower investment and operating costs thanks to smaller number of luminaires and lamps. ...
BQ2084-V150 数据资料 dataSheet 下载
... The bq2084-V150 does not measure charge or discharge counts below the digital filter threshold. The digital filter threshold is programmed in the Digital Filter DF 0x2c and should be set sufficiently high to prevent false signal detection with no charge or discharge flowing through the sense resisto ...
... The bq2084-V150 does not measure charge or discharge counts below the digital filter threshold. The digital filter threshold is programmed in the Digital Filter DF 0x2c and should be set sufficiently high to prevent false signal detection with no charge or discharge flowing through the sense resisto ...
AD9241 数据手册DataSheet 下载
... The input of the AD9241 is highly flexible, allowing for easy interfacing to imaging, communications, medical, and dataacquisition systems. A truly differential input structure allows for both single-ended and differential input interfaces of varying input spans. The sample-and-hold amplifier (SHA) ...
... The input of the AD9241 is highly flexible, allowing for easy interfacing to imaging, communications, medical, and dataacquisition systems. A truly differential input structure allows for both single-ended and differential input interfaces of varying input spans. The sample-and-hold amplifier (SHA) ...
Sensorless Start-up and Control of Permanent Magnet Synchronous
... of subsea pump motors with long tieback distance and high breakaway torque becomes more and more relevant. Lack of sufficient expertise and right tools for analyses and calculations can easily lead to over dimensioned components; along with its unwanted consequences on component size, weight and cos ...
... of subsea pump motors with long tieback distance and high breakaway torque becomes more and more relevant. Lack of sufficient expertise and right tools for analyses and calculations can easily lead to over dimensioned components; along with its unwanted consequences on component size, weight and cos ...
FZT458 Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
MMPF0200Z, 12 Channel Configurable Power Management
... Programmable (OTP) memory, the PF0200Z is available in preprogrammed standard versions, or non-programmed to support custom programming. The PF0200Z is especially suited to the i.MX 6SoloLite, i.MX 6Solo and i.MX 6DualLite versions of the i.MX 6 family of devices and is supported by full system leve ...
... Programmable (OTP) memory, the PF0200Z is available in preprogrammed standard versions, or non-programmed to support custom programming. The PF0200Z is especially suited to the i.MX 6SoloLite, i.MX 6Solo and i.MX 6DualLite versions of the i.MX 6 family of devices and is supported by full system leve ...
PDR 9000 Operation and Maintenance Manual
... MKS 907, a MKS 903 or both gauges may be used to provide continuous measurement over 14 decades with autoranging. The PDR 9000 precisely measures the analog signal from either transducer to determine pressure. When autoranging, the PDR 9000 automatically smooths the pressure reading over the range o ...
... MKS 907, a MKS 903 or both gauges may be used to provide continuous measurement over 14 decades with autoranging. The PDR 9000 precisely measures the analog signal from either transducer to determine pressure. When autoranging, the PDR 9000 automatically smooths the pressure reading over the range o ...
DMN4026SSD Product Summary Features
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Characteristic frequencies in averaged description of step
... The methods of converter design, in particular their control circuits are considered in textbooks and papers [1, 2, 6-10] as well as in manufacturer’s technical reports and application notes, for example [11-15]. In a standard approach, an analog control circuit is used, based on an error amplifier. ...
... The methods of converter design, in particular their control circuits are considered in textbooks and papers [1, 2, 6-10] as well as in manufacturer’s technical reports and application notes, for example [11-15]. In a standard approach, an analog control circuit is used, based on an error amplifier. ...
FCX1053A Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
AD9241 Complete 14-Bit, 1.25 MSPS Monolithic A/D Converter
... The input of the AD9241 is highly flexible, allowing for easy interfacing to imaging, communications, medical, and dataacquisition systems. A truly differential input structure allows for both single-ended and differential input interfaces of varying input spans. The sample-and-hold amplifier (SHA) ...
... The input of the AD9241 is highly flexible, allowing for easy interfacing to imaging, communications, medical, and dataacquisition systems. A truly differential input structure allows for both single-ended and differential input interfaces of varying input spans. The sample-and-hold amplifier (SHA) ...
DS2000 USER`S MANUAL (rev.C)
... closed electrical operating areas kept locked. Where Electronic Equipment requires manual intervention, 412.2.1 of HD 384.4.41 S2 shall be consulted. ...
... closed electrical operating areas kept locked. Where Electronic Equipment requires manual intervention, 412.2.1 of HD 384.4.41 S2 shall be consulted. ...
NVT4555 1. General description SIM card interface level translator and supply voltage LDO
... Resistance (ESR) are used respectively at the battery (VBAT) and VCC input terminals of the NVT4555. X5R and X7R type multi-layer ceramic capacitors (MLCC) are preferred because they have minimal variation in value and ESR over temperature. The maximum ESR should be < 500 m(50 m typical). Also, a ...
... Resistance (ESR) are used respectively at the battery (VBAT) and VCC input terminals of the NVT4555. X5R and X7R type multi-layer ceramic capacitors (MLCC) are preferred because they have minimal variation in value and ESR over temperature. The maximum ESR should be < 500 m(50 m typical). Also, a ...