LMX2370/LMX2371/LMX2372 PLLatinum Dual Frequency Synthesizer for RF Personal Communications
... such as the National Semiconductor LMX2370/2371/2372, a voltage controlled oscillator (VCO), and a passive loop filter. The frequency synthesizer includes a phase detector, a current mode charge pump, as well as programmable reference [R] and feedback [N] frequency dividers. The VCO frequency is est ...
... such as the National Semiconductor LMX2370/2371/2372, a voltage controlled oscillator (VCO), and a passive loop filter. The frequency synthesizer includes a phase detector, a current mode charge pump, as well as programmable reference [R] and feedback [N] frequency dividers. The VCO frequency is est ...
Manual
... Protective circuits are provided to sense an overcurrent or an open circuit in the series lighting loop and shutdown the regulator. The front panel display alerts maintenance personnel to the nature of the shutdown. The protective circuitry can be reset by setting the regulator control switch to off ...
... Protective circuits are provided to sense an overcurrent or an open circuit in the series lighting loop and shutdown the regulator. The front panel display alerts maintenance personnel to the nature of the shutdown. The protective circuitry can be reset by setting the regulator control switch to off ...
Secure Application of Transformer Differential Relays for Bus
... a high-impedance grounded system where the single line to ground (SLG) fault current levels may be very low. 2) Percentage-Restrained Differential Relays The percentage-restrained characteristic operates on the ratio of: • Operate current—also called the differential current. It is the phasor sum of ...
... a high-impedance grounded system where the single line to ground (SLG) fault current levels may be very low. 2) Percentage-Restrained Differential Relays The percentage-restrained characteristic operates on the ratio of: • Operate current—also called the differential current. It is the phasor sum of ...
User Manual - Sonel Analysis
... "Settings" window will be displayed as shown in Fig. 12. It is the most important part of the analyzer configuration. Here the user determines which parameters will be recorded by the analyzer; the mains type and nominal values of the parameters. The left part of the screen is divided into two parts ...
... "Settings" window will be displayed as shown in Fig. 12. It is the most important part of the analyzer configuration. Here the user determines which parameters will be recorded by the analyzer; the mains type and nominal values of the parameters. The left part of the screen is divided into two parts ...
THESE DE DOCTORAT Monsieur Xusheng WANG
... system. The proposed power amplifier is manufactured by using of printed circuit board (PCB) and discrete components. According to the test results, the proposed power amplifier has a power efficiency of 82% with 3 W output power at 1.25 MHz working frequency. The automatic impedance tuning system p ...
... system. The proposed power amplifier is manufactured by using of printed circuit board (PCB) and discrete components. According to the test results, the proposed power amplifier has a power efficiency of 82% with 3 W output power at 1.25 MHz working frequency. The automatic impedance tuning system p ...
ECE 3130 * Digital Electronics and Design
... • Review basic digital circuit concepts • Develop an understanding of digital circuit design and simulation • Learn the basics of the Tanner Tools software ...
... • Review basic digital circuit concepts • Develop an understanding of digital circuit design and simulation • Learn the basics of the Tanner Tools software ...
MPQ8636 - Monolithic Power System
... load and line regulation. The MPQ8636 operates at high efficiency over a wide output-current–load range. The MPQ8636 uses Constant-On-Time (COT) control to provide a fast transient response and ease loop stabilization. An external resistor programs the operating frequency from 200kHz to 1MHz, and th ...
... load and line regulation. The MPQ8636 operates at high efficiency over a wide output-current–load range. The MPQ8636 uses Constant-On-Time (COT) control to provide a fast transient response and ease loop stabilization. An external resistor programs the operating frequency from 200kHz to 1MHz, and th ...
... In this work, a fully differential Operational Amplifier (OpAmp) with high Gain-Bandwidth (GBW), high linearity and Signal-to-Noise ratio (SNR) has been designed in 65nm CMOS technology with 1.1v supply voltage. The performance of the OpAmp is evaluated using Cadence and Matlab simulations and it sa ...
FZT853 Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
MAX2871 - Maxim Part Number Search
... The MAX2871 is an ultra-wideband phase-locked loop (PLL) with integrated voltage control oscillators (VCOs) capable of operating in both integer-N and fractional-N modes. When combined with an external reference oscillator and loop filter, the MAX2871 is a high-performance frequency synthesizer capa ...
... The MAX2871 is an ultra-wideband phase-locked loop (PLL) with integrated voltage control oscillators (VCOs) capable of operating in both integer-N and fractional-N modes. When combined with an external reference oscillator and loop filter, the MAX2871 is a high-performance frequency synthesizer capa ...
ZX5T851G Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
Design Document
... One problem posed by this design is going to be designing a rechargeable battery that can charge while the system is running off of AC power, and then power the system in the event of a power outage. It is important to properly charge the battery while running off of main power so that it doesn’t be ...
... One problem posed by this design is going to be designing a rechargeable battery that can charge while the system is running off of AC power, and then power the system in the event of a power outage. It is important to properly charge the battery while running off of main power so that it doesn’t be ...
Catalog KEB COMBIVERT G6
... G6-SCL (synchronous-sensorless control) synchronous motors The two level parameter structure with basic (customer parameters) and application menu (application parameters) gives KEB COMBIVERT G6 a unique user friendly and easy handling high functionality. With the exception of the versions with fie ...
... G6-SCL (synchronous-sensorless control) synchronous motors The two level parameter structure with basic (customer parameters) and application menu (application parameters) gives KEB COMBIVERT G6 a unique user friendly and easy handling high functionality. With the exception of the versions with fie ...
INSTRUMENT TRANSFORMER DIMENSIONING FOR SUBSTATIONS Ronny Mustajärvi
... 2.2 Voltage Transformers Voltage transformers or VT's also called potential transformers are instrument transformers that convert a generally high primary voltage to a lower secondary voltage that can be connected to standard measuring or protection devices. There are two primary types of voltage tr ...
... 2.2 Voltage Transformers Voltage transformers or VT's also called potential transformers are instrument transformers that convert a generally high primary voltage to a lower secondary voltage that can be connected to standard measuring or protection devices. There are two primary types of voltage tr ...
MAX98358 PDM Input Class D Audio Power Amplifier General Description Features
... offers five selectable gain settings (3dB, 6dB, 9dB, 12dB, and 15dB) set by a single gain-select input (GAIN). The IC can be configured to produce a left channel, right channel, or (left/2 + right/2) output from the stereo input data. The MAX98358 takes a stereo pulse density modulated (SPDM) input ...
... offers five selectable gain settings (3dB, 6dB, 9dB, 12dB, and 15dB) set by a single gain-select input (GAIN). The IC can be configured to produce a left channel, right channel, or (left/2 + right/2) output from the stereo input data. The MAX98358 takes a stereo pulse density modulated (SPDM) input ...
HW manual - TG Drives
... All rights reserved. No part of this work may be reproduced in any form (by printing, photocopying, microfilm or any other method) or stored, processed, copied or distributed by electronic means without the written permission of Danaher Motion. ...
... All rights reserved. No part of this work may be reproduced in any form (by printing, photocopying, microfilm or any other method) or stored, processed, copied or distributed by electronic means without the written permission of Danaher Motion. ...
Plasma Arc Cutting System - Air
... in compliance with standard EN50199. To ensure that the equipment works in a compatible manner with other radio and electronic systems, the equipment should be installed and used in accordance with the information below to achieve electromagnetic compatibility. The limits required by EN50199 may not ...
... in compliance with standard EN50199. To ensure that the equipment works in a compatible manner with other radio and electronic systems, the equipment should be installed and used in accordance with the information below to achieve electromagnetic compatibility. The limits required by EN50199 may not ...
BDTIC www.BDTIC.com/infineon Industrial Automation Efficient & Robust Semiconductor Solutions
... the collected data and communication to the main PLC via field bus. Communication between a peripheral PLC and the end device is usually a point‑topoint connection. There are also intelligent communication standards established, which provide, in addition, remote parameterization and diagnostics of ...
... the collected data and communication to the main PLC via field bus. Communication between a peripheral PLC and the end device is usually a point‑topoint connection. There are also intelligent communication standards established, which provide, in addition, remote parameterization and diagnostics of ...
Manual (Units installed prior to Nov 2006)
... Protective circuits are provided to sense an overcurrent or an open circuit in the series lighting loop and shutdown the regulator. The front panel display alerts maintenance personnel to the nature of the shutdown. The protective circuitry can be reset by setting the regulator control switch to off ...
... Protective circuits are provided to sense an overcurrent or an open circuit in the series lighting loop and shutdown the regulator. The front panel display alerts maintenance personnel to the nature of the shutdown. The protective circuitry can be reset by setting the regulator control switch to off ...
Oscillator Phase Noise: A Tutorial
... bit larger than predicted by (12), because there are additional important noise sources besides tank loss. For example, any physical implementation of an energy restorer will be noisy. ...
... bit larger than predicted by (12), because there are additional important noise sources besides tank loss. For example, any physical implementation of an energy restorer will be noisy. ...