MAX31913 - Maxim Part Number Search
... conditions, and serializes the 24V digital output of sensors and switches used in industrial, process, and building automation to 5V CMOS-compatible signals required by microcontrollers. It provides the front-end interface circuit of a programmable logic controller (PLC) digital input module. The de ...
... conditions, and serializes the 24V digital output of sensors and switches used in industrial, process, and building automation to 5V CMOS-compatible signals required by microcontrollers. It provides the front-end interface circuit of a programmable logic controller (PLC) digital input module. The de ...
FINAL SAFETY ANALYSIS REPORT CHAPTER 8 ELECTRIC POWER BBNPP FSAR
... The U.S. EPR FSAR includes the following COL Item in Section 8.2.1.1. A COL applicant that references the U.S. EPR design certification will provide site specific information regarding the communication agreements and protocols between the station and the transmission system operator, independent sy ...
... The U.S. EPR FSAR includes the following COL Item in Section 8.2.1.1. A COL applicant that references the U.S. EPR design certification will provide site specific information regarding the communication agreements and protocols between the station and the transmission system operator, independent sy ...
COLOR TELEVISION TRAINING MANUAL Chassis Series VB8B
... yoke. Thus the deflection velocity of the electron beam is modulated by the SVM magnetic field resulting in a change of brightness. The total horizontal deflection magnetic field applied to the electron beam results in waveform (d). The horizontal electron beam velocity changes as shown in (e) and t ...
... yoke. Thus the deflection velocity of the electron beam is modulated by the SVM magnetic field resulting in a change of brightness. The total horizontal deflection magnetic field applied to the electron beam results in waveform (d). The horizontal electron beam velocity changes as shown in (e) and t ...
+ + + + + + + + Space charge region
... V - I Characteristics of PN Junction The diode can be operated in two different ways, as Forward and Reverse bias. When positive terminal of the battery is connected to the P-type & negative terminal is to the N-type of the PN-junction diode, known the diode is in forward bias. When negative termin ...
... V - I Characteristics of PN Junction The diode can be operated in two different ways, as Forward and Reverse bias. When positive terminal of the battery is connected to the P-type & negative terminal is to the N-type of the PN-junction diode, known the diode is in forward bias. When negative termin ...
LT1739 - Dual 500mA, 200MHz xDSL Line Driver Amplifier
... modes. For proper operation of the current control circuitry, it is necessary that the SHDNREF pin be biased at least 2V more positive than V –. In single supply applications where V – is at ground potential, special attention to the DC bias of the SHDNREF pin is required. Contact ...
... modes. For proper operation of the current control circuitry, it is necessary that the SHDNREF pin be biased at least 2V more positive than V –. In single supply applications where V – is at ground potential, special attention to the DC bias of the SHDNREF pin is required. Contact ...
OPA693: Ultra-Wideband, Fixed Gain Video Buffer Amplifier with
... at 25°C. This trim, along with low drift over temperature, ensures lower maximum supply current than competing products that report only a room temperature nominal supply current. System power may be further reduced by using the optional disable control pin. Leaving this disable pin open, or holding ...
... at 25°C. This trim, along with low drift over temperature, ensures lower maximum supply current than competing products that report only a room temperature nominal supply current. System power may be further reduced by using the optional disable control pin. Leaving this disable pin open, or holding ...
LTC4415 - Dual 4A Ideal Diodes with Adjustable Current Limit
... Forward conduction of the LTC4415 diodes has three operating ranges as a function of the load current, as shown in Figure 1 and described below: 1. For small load current, a low forward voltage drop (VFR = 15mV typical) is maintained by modulating the series resistance offered by the PFETs (P1/P2) i ...
... Forward conduction of the LTC4415 diodes has three operating ranges as a function of the load current, as shown in Figure 1 and described below: 1. For small load current, a low forward voltage drop (VFR = 15mV typical) is maintained by modulating the series resistance offered by the PFETs (P1/P2) i ...
WEG Soft Starters Training
... A Reduced Voltage Soft Starter (RVSS) helps protect the motor and connected equipment from damage by controlling the terminal voltage • The soft starter reduces the motor terminal voltage producing a more regulated motor acceleration up to full speed • Soft starters are also capable of providing a g ...
... A Reduced Voltage Soft Starter (RVSS) helps protect the motor and connected equipment from damage by controlling the terminal voltage • The soft starter reduces the motor terminal voltage producing a more regulated motor acceleration up to full speed • Soft starters are also capable of providing a g ...
DP0150ADJ / DP0150BDJ Features Mechanical Data
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
EE 423 – Power System Analysis 2 Power System Fault Analysis
... of a busbar (or the ability to maintain its voltage) is directly proportional to its SCC. An infinitely strong bus (or Infinite bus bar) has an infinite SCC, with a zero equivalent impedance and will maintain its voltage under all conditions. Magnitude of short circuit current is time dependant due ...
... of a busbar (or the ability to maintain its voltage) is directly proportional to its SCC. An infinitely strong bus (or Infinite bus bar) has an infinite SCC, with a zero equivalent impedance and will maintain its voltage under all conditions. Magnitude of short circuit current is time dependant due ...
RURG5060_F085 50A, 600V Ultrafast Rectifier RURG5060_F085 50A, 600V Features
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild’s quality standards for handing and storage and provide access to Fairchild’s ...
... Distributors who are listed by country on our web page cited above. Products customers buy either from Fairchild directly or from Authorized Fairchild Distributors are genuine parts, have full traceability, meet Fairchild’s quality standards for handing and storage and provide access to Fairchild’s ...
Wireless power and data transfer
... interface [6]-[11], the WPT technique enhances the devices safety and decreases the connectivity complexity. For most applications, reliable communication between the primary side and the pickup side plays an essential role in a well-designed WPT system. For instance, the functions such as output vo ...
... interface [6]-[11], the WPT technique enhances the devices safety and decreases the connectivity complexity. For most applications, reliable communication between the primary side and the pickup side plays an essential role in a well-designed WPT system. For instance, the functions such as output vo ...
Medium Voltage Equipment Section 15 Section Updated 04 / 2011
... to form a single line-up assembly. The entire center may be powered by incoming line connection at a single point. When requested and possible, Limitamp motor control centers bear UL section and unit labels. Limitamp Control is designed to meet NEMA ICS 3, Part 2 and UL 347 requirements. Various enc ...
... to form a single line-up assembly. The entire center may be powered by incoming line connection at a single point. When requested and possible, Limitamp motor control centers bear UL section and unit labels. Limitamp Control is designed to meet NEMA ICS 3, Part 2 and UL 347 requirements. Various enc ...
HPH-12/30-D48 Series
... greatest safety, we recommend a fast blow fuse installed in the ungrounded input supply line. The installer must observe all relevant safety standards and regulations. For safety agency approvals, install the converter in compliance with the end-user safety standard, i.e. IEC/EN/UL 60950-1. Input Re ...
... greatest safety, we recommend a fast blow fuse installed in the ungrounded input supply line. The installer must observe all relevant safety standards and regulations. For safety agency approvals, install the converter in compliance with the end-user safety standard, i.e. IEC/EN/UL 60950-1. Input Re ...
Commercial PV Using the Enphase M
... Systems. Use Enlighten to access and monitor your fleet of PV installations down to the individual module. Enlighten provides detailed diagnostics so that you can determine whether a system is performing as expected. Enphase Line Communications Filter (LCF): When a project requires more than one Env ...
... Systems. Use Enlighten to access and monitor your fleet of PV installations down to the individual module. Enlighten provides detailed diagnostics so that you can determine whether a system is performing as expected. Enphase Line Communications Filter (LCF): When a project requires more than one Env ...
S824MCC/MCCH - P84478
... B. Connect one other color wire (in the interconnecting cable) to the amplifier output terminal marked 25V or 70V and to all of the “+” terminals at each speaker input. The setting of “J1” must match the amplifier output of 25V or 70V. C. If shielded cable is used, then connect the shield (in the in ...
... B. Connect one other color wire (in the interconnecting cable) to the amplifier output terminal marked 25V or 70V and to all of the “+” terminals at each speaker input. The setting of “J1” must match the amplifier output of 25V or 70V. C. If shielded cable is used, then connect the shield (in the in ...
NCP1250 - ON Semiconductor
... internal reference voltage Vlatch, then the circuit permanently latches off. The VCC pin is pulled down to a fixed level, keeping the controller latched. The latch reset occurs when the user disconnects the adapter from the mains and lets the VCC falls below the VCC reset. Short−circuit protection: ...
... internal reference voltage Vlatch, then the circuit permanently latches off. The VCC pin is pulled down to a fixed level, keeping the controller latched. The latch reset occurs when the user disconnects the adapter from the mains and lets the VCC falls below the VCC reset. Short−circuit protection: ...