• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Control principles of micro-source inverters used in microgrid
Control principles of micro-source inverters used in microgrid

... the high-efficiency, less-polluting distributed generation (DG) has received increasing attentions [1, 2]. Microgrids [3–5], which comprise micro-sources, energy storage devices, loads, and control and protection system, are the most effective carrier of DGs. When a microgrid is connects to the util ...
24V, 15A Step-Down Regulator in Sub
24V, 15A Step-Down Regulator in Sub

... Monolithic switching regulators and switching controllers together dominate the DC/DC converter market. Generally, there is little overlap in their respective applications. Controller-based solutions are favored for high performance, higher power applications where minimal power loss and top thermal ...
ON DELAY | INLINE (SERIES CONNECTION)
ON DELAY | INLINE (SERIES CONNECTION)

... to select any time delay. The THL-8 Series is a compact 2” x 2” encapsulated enclosure with a universal input voltage. It is connected in series with the load requiring only 2 terminals/connections. ...
Directly-coupled Fee..
Directly-coupled Fee..

... The direct coupling between the gain stage and the split-load phase inverter stage is useful when you are applying large doses of loop negative feedback around a few stages because it leaves out one R-C phase shift element. The number of phase shift elements can become critical when your feedback wo ...
III. Proposed controller design
III. Proposed controller design

... control methods based on PI-R controller were widely used in DFIG system for operating in harmonically distorted or unbalanced stator voltage conditions. In this paper, a new control system is proposed for keeping DFIG-based wind turbine connected to the grid in worst NonIdeal grid voltage condition ...
to print
to print

... only two amplification stages, no global feedback and regulated independent supplies for each channel. However, the Special Edition version offers some important ...
Capacitor as power factor improvement it`s
Capacitor as power factor improvement it`s

IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)

... Fig. 1: Complete circuit diagram of the security alarm. 2.1 Transformer A transformer is an electronic device that transfers electrical energy from one circuit to another through inductively coupled conductors known as the transformer's coils. A transformer has a primary coil and a secondary coil. I ...
Super low loss transformers
Super low loss transformers

... full advantage of reducing their site operating voltage. ...
Aalborg Universitet Model Predictive Current Control for High-Power Grid-Connected Converters with
Aalborg Universitet Model Predictive Current Control for High-Power Grid-Connected Converters with

... and the input producing the state with the lowest cost is applied during the following sampling instant. In this way, an on-line optimization control algorithm is obtained. This is particularly suitable for a 3-level NPC converter since it is possible to predict the system behavior for each of the 2 ...
24_Banach_newp - Instytut Maszyn, Napędów i Pomiarów
24_Banach_newp - Instytut Maszyn, Napędów i Pomiarów

... – difficulty to find the minimum of the input power while the load and the supply voltage are changing. The major advantage is, that a search controller does not require knowledge of any motor parameters. In consideration of these disadvantages, will be often used a control strategy based on the los ...
Q. For a CMOS inverter with matched MOSFET`s having Vt=1V find
Q. For a CMOS inverter with matched MOSFET`s having Vt=1V find

... (i.e.,Ln = Lp= 1.2 µm). If Wn = 1.8 µm, find the value of Wp that would result in QN and QP being matched. For this technology, k'n = 80 µA/V2, k'p = 27 µA/V2, Vtn = 0.8 V, and VDD = 5V. Also, calculate the value: of the output resistance of the inverter when v0 = V0L. ...
Aalborg Universitet
Aalborg Universitet

DN24733737
DN24733737

Embedded Computing
Embedded Computing

... Worth one engineer year in code development to save $1 on system that will ship 1M units Assembly coding easier than ASIC chip design But, room for improvement… ...
Distribution State Estimator
Distribution State Estimator

... which solves for all distribution system topologies (radial, looped, meshed), including heavily meshed systems such as secondary grid networks. The details provided by the module help the distribution engineer design the best solution to the problems identified. The module is seamlessly integrated t ...
Microcontroller Systems ELET 3232 Topic 19: Hardware Design Concepts #1
Microcontroller Systems ELET 3232 Topic 19: Hardware Design Concepts #1

Cooperation of induction squirrel
Cooperation of induction squirrel

introduction
introduction

... • Wind farms must be capable of operating continuously within the voltage and frequency variation limits encountered in normal operation of the system. • Further, they should remain in operation in case of voltage and frequency excursions outside the normal operation limits, for a limited time and i ...
Voltage-Controlled Oscillator
Voltage-Controlled Oscillator

Data Sheet, Type 5148
Data Sheet, Type 5148

... Model 5148 is an economical 16-channel power supply/coupler that provides constant current excitation for, Piezotron, PiezoBeam®, K-Shear®, Ceramic Shear and other similar piezoelectric voltage mode sensors. The coupler can also power external impedance converters and fixed gain in-line charge conve ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... liquefied natural gas plants, water plants, marine propulsion, power generation, energy transmission, and powerquality devices, FACTS Devices [1-3]. Cascaded H-bridge converter topology is prominently used and particularly useful for renewable energy and DSTATCOM applications [4-5], [9]. While in co ...
Line Diagrams And The Per Unit System
Line Diagrams And The Per Unit System

Distributed Generation - About the Department | University
Distributed Generation - About the Department | University

High Definition Stereo Headphone Amplifier Ear+ Purist HD Ear+ HD
High Definition Stereo Headphone Amplifier Ear+ Purist HD Ear+ HD

... saturation of the iron core, para (parallel)-feed is used so only the signal flows through coupling capacitor C3a and to the primary of TR3a. The turns ratio of TR3a is approximately 8.7:1, which reduces the output voltage swing available to drive the headphones. However, it also provides an impedan ...
< 1 ... 1119 1120 1121 1122 1123 1124 1125 1126 1127 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report