• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
STK730-080
STK730-080

... semiconductor products fail with some probability. It is possible that these probabilistic failures could give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire, or that could cause damage to other property. When designing equipment, adopt safety meas ...
ATP-Y/Analog Input to Pulse (Relay)
ATP-Y/Analog Input to Pulse (Relay)

... Be sure to follow all local electrical codes. Refer to wiring diagram for connection information. Make all connections with the power off. 1.) The secondary supply voltage to the interface should be between 22 and 28 volts AC or DC and isolated from earth ground, chassis ground, and neutral leg of t ...
blue`log x-series
blue`log x-series

... (DI), (AI), (fix), (U), (P × tanφ(fix)) ...
radial beam power tetrode 4cx250b/m 7203a
radial beam power tetrode 4cx250b/m 7203a

... regulation is poor or where an increase in screen current above the normal value will cause a significant reduction in voltage. At UHF increased output (cavity) loading is recommended to reduce screen current even if the overall tube efficiency is reduced somewhat. FAULT PROTECTION - All power tubes ...
LECTURER-26 GENERATION OF IMPULSE CURRENTS Lightning
LECTURER-26 GENERATION OF IMPULSE CURRENTS Lightning

... current i m will be given by the equation ...
Train Detection - North River Railway
Train Detection - North River Railway

... • This diagram shows two “light guns” (the emitter and detector) mounted between the rails and pointing upwards toward the bottom of a passing train. • Fortunately Reflective Detection is less sensitive to movements in the room than simple direct detection. • Unfortunately the underside of a car or ...
The highest sound quality at all volume levels, flat frequency
The highest sound quality at all volume levels, flat frequency

Microgrids Modelling Testing - Spiral
Microgrids Modelling Testing - Spiral

LR-24 ELECTROFISHER
LR-24 ELECTROFISHER

... The Power Limit Key allows the user to limit the maximum average output power. It is defaulted to 400 W, which is the maximum average power output that the LR-24 is capable of producing. It can be changed easily to a lower limit, which can be useful if a study requires staying within a certain power ...
RPI-1133
RPI-1133

... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
application of M/s OPTCL for levy of Grid Support Charges (GSC)
application of M/s OPTCL for levy of Grid Support Charges (GSC)

... An application of M/s OPTCL for levy of Grid Support Charges (GSC) for the Captive Generating Plants running in parallel with the grid of the Odisha Power Transmission Corporation Ltd. (OPTCL). WHEREAS M/s OPTCL, the Transmission Licensee has filed an application for levy of Grid Support Charges (GS ...
mobile phone detector
mobile phone detector

... voltage producing a logic high signal and the LED starts glowing, to indicate the presence of a mobile phone.  The circuit has to be placed centimeters away from the object to be detected. ...
Grid Code Impact on Electrical Machine Design
Grid Code Impact on Electrical Machine Design

Oscilloscope and High Voltage Probe Facilitage Motor
Oscilloscope and High Voltage Probe Facilitage Motor

... bracket that part of the waveform. In this instance, the voltage would be 602 volts. Both of these values are well within the tolerance of the IGBT breakdown voltage specification and easily within the limits of the TDS 360/P5100 measurement system. ...
VIPer100 - Hobbielektronika.hu
VIPer100 - Hobbielektronika.hu

... Housed in the 5 pin TO-220, as well as in the PowerSO-10 surface mounting package, it offers maximum flexibility to designers allowing both primary or secondary regulation loop, despite using around 50% less components than a discrete solution. ...
8.  Electric Power AP1000 Design Control Document
8. Electric Power AP1000 Design Control Document

... A transmission system to supply offsite ac energy for startup and normal shutdown through a sitespecific transmission switchyard is as described in subsection 8.2.5. This offsite ac power system is not required for plant safety. [[A transformer area containing stepup transformers, unit auxiliary tra ...
Dynamic Resistance
Dynamic Resistance

... In a standard power supply that regulates output voltage the load resistance has a simple calculation: RO = VO / IO LEDs are PN junction diodes with a dynamic resistance that shifts as their forward current changes. When the load is an LED or string of LEDs, the load resistance is replaced with the ...
tip31, tip31a, tip31b, tip31c npn silicon power transistors
tip31, tip31a, tip31b, tip31c npn silicon power transistors

... Power Innovations Limited (PI) reserves the right to make changes to its products or to discontinue any semiconductor product or service without notice, and advises its customers to verify, before placing orders, that the information being relied on is current. PI warrants performance of its semicon ...
Physics 173 / BGGN 266 Primer on Nonlinear OpAmp Circuits
Physics 173 / BGGN 266 Primer on Nonlinear OpAmp Circuits

Chapter 6 - UniMAP Portal
Chapter 6 - UniMAP Portal

Tool Box Talk Electrical Safety
Tool Box Talk Electrical Safety

... operating at 50 volts or more. The primary hazards associated with contact with live circuits include shock, electrocutions, indirect injuries associated with falls or other contact hazards resulting from involuntary muscle reactions. Most electrical circuits used in everyday construction applicatio ...
UMS-800-A16-G
UMS-800-A16-G

... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
Matlab Modeling and Simulation of Grid Connected Wind
Matlab Modeling and Simulation of Grid Connected Wind

UMZ-104-A16-G
UMZ-104-A16-G



< 1 ... 1117 1118 1119 1120 1121 1122 1123 1124 1125 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report