MAX17067 Low-Noise Step-Up DC-DC Converter General Description Features
... the frequency is 1.2MHz. This input has a 5μA pulldown current. Soft-Start Control Pin. Connect a soft-start capacitor (CSS) to this pin. Leave open for no soft-start. The softstart capacitor is charged with a constant current of 4μA. Full current limit is reached after t = 2.5 x 105 CSS. The soft-s ...
... the frequency is 1.2MHz. This input has a 5μA pulldown current. Soft-Start Control Pin. Connect a soft-start capacitor (CSS) to this pin. Leave open for no soft-start. The softstart capacitor is charged with a constant current of 4μA. Full current limit is reached after t = 2.5 x 105 CSS. The soft-s ...
Concept 2 - RF Staples Secondary School
... High voltage is more dangerous than low voltage Small voltages can kill if the shock carries a significant amount of amps ...
... High voltage is more dangerous than low voltage Small voltages can kill if the shock carries a significant amount of amps ...
High Efficiency, Fast Transient, 7A, 28V Synchronous Step
... Hence, the output capacitors discharge slowly to GND through LS-FET. As a result, the efficiency at light load condition is greatly improved. At light load condition, the HS-FET is not turned ON as frequently as at heavy load condition. This is called skip mode. ...
... Hence, the output capacitors discharge slowly to GND through LS-FET. As a result, the efficiency at light load condition is greatly improved. At light load condition, the HS-FET is not turned ON as frequently as at heavy load condition. This is called skip mode. ...
Happy Halloween Chapter 33 LC Circuits
... Initially the current flows easily, but then drops exponentially as the capacitor get filled up. ...
... Initially the current flows easily, but then drops exponentially as the capacitor get filled up. ...
ECP 11-0213 Transformer (and Reactor) Test
... Document Number: ECP 11-0213 Version: 3.0 Date: 30/01/2017 ...
... Document Number: ECP 11-0213 Version: 3.0 Date: 30/01/2017 ...
switching voltage regulator and variable current limiter
... the fuse’s limits, it blows and therefore disconnects the load from the source, preventing further current from damaging the load. This is common method for protecting house-hold mains. A similar device is the circuit breaker. While fuses are simple and secure, the drawback is that once they are blo ...
... the fuse’s limits, it blows and therefore disconnects the load from the source, preventing further current from damaging the load. This is common method for protecting house-hold mains. A similar device is the circuit breaker. While fuses are simple and secure, the drawback is that once they are blo ...
Ultra-Thin, Small Footprint 1-W, 12- to 36
... As most of the analog PLC I/O modules are space constrained, the TIDA-00237 aims at keeping the transformer height below 5 mm and a small overall footprint. This has a major influence on the component selection, which is described in Table 2. As the transformer T1 has to be below 5-mm height, an ER9 ...
... As most of the analog PLC I/O modules are space constrained, the TIDA-00237 aims at keeping the transformer height below 5 mm and a small overall footprint. This has a major influence on the component selection, which is described in Table 2. As the transformer T1 has to be below 5-mm height, an ER9 ...
CLAS12 Drift Chamber Electronics
... CLAS12 Drift Chamber Electronics ‘Post Amplifier’ circuit section From Amplifier-Discriminator Board ...
... CLAS12 Drift Chamber Electronics ‘Post Amplifier’ circuit section From Amplifier-Discriminator Board ...
LT1513/LT1513-2 - Linear Technology
... The LT1513 is an IC battery charger chip specifically optimized to use the SEPIC converter topology. A complete charger schematic is shown in Figure 1. The SEPIC topology has unique advantages for battery charging. It will operate with input voltages above, equal to or below the battery voltage, has ...
... The LT1513 is an IC battery charger chip specifically optimized to use the SEPIC converter topology. A complete charger schematic is shown in Figure 1. The SEPIC topology has unique advantages for battery charging. It will operate with input voltages above, equal to or below the battery voltage, has ...
MAX17409 Evaluation Kit Evaluates: General Description Features
... The MAX17409 has an internal digital-to-analog converter (DAC) that programs the output voltage. The output voltage can be digitally set from 0.3375V to 1.1250V (see Table 1) using the D0–D5 pins. There are two ways to set the output voltage: U Drive the external VID0–VID5 inputs (all SW1 positions ...
... The MAX17409 has an internal digital-to-analog converter (DAC) that programs the output voltage. The output voltage can be digitally set from 0.3375V to 1.1250V (see Table 1) using the D0–D5 pins. There are two ways to set the output voltage: U Drive the external VID0–VID5 inputs (all SW1 positions ...
BDTIC C C M - P F C
... current loop and the outer voltage loop. The inner current loop of the IC controls the sinusoidal profile for the average input current. It uses the dependency of the PWM duty cycle on the line input voltage to determine the corresponding input current. This means the average input current follows t ...
... current loop and the outer voltage loop. The inner current loop of the IC controls the sinusoidal profile for the average input current. It uses the dependency of the PWM duty cycle on the line input voltage to determine the corresponding input current. This means the average input current follows t ...
Residual voltage on load side of an open circuit breaker
... before maintenance is performed. In a drawout, metal-clad switchgear situation, the circuit breaker should be withdrawn from the connected position to the test or disconnected position, as IEEE C37.20.2 recognizes this as the condition that fulfills the function of an isolator. The National Electric ...
... before maintenance is performed. In a drawout, metal-clad switchgear situation, the circuit breaker should be withdrawn from the connected position to the test or disconnected position, as IEEE C37.20.2 recognizes this as the condition that fulfills the function of an isolator. The National Electric ...