ABB Template
									
... • Full Newton Raphson solution, modeling is derived phase based • Object oriented C++ code • High performance commercial FORTRAN sparse matrix storage and factorization ...
                        	... • Full Newton Raphson solution, modeling is derived phase based • Object oriented C++ code • High performance commercial FORTRAN sparse matrix storage and factorization ...
									theremin - Courses
									
... touch the theremin, he has no point of reference for tuning notes and nothing to steady his hand. ...
                        	... touch the theremin, he has no point of reference for tuning notes and nothing to steady his hand. ...
									View_pdf - International Journal of Computer Science and Mobile
									
... alone in the EVs to satisfy the load demands, particularly during startup and transient events. So, in order to solve these problems, usually FC is used with energy storage systems (ESSs) such as batteries or super capacitor (SC). Furthermore, the association of FC and ESSs leads to a reduction of t ...
                        	... alone in the EVs to satisfy the load demands, particularly during startup and transient events. So, in order to solve these problems, usually FC is used with energy storage systems (ESSs) such as batteries or super capacitor (SC). Furthermore, the association of FC and ESSs leads to a reduction of t ...
									ADVANCES IN INTERPRETING PARTIAL DISCHARGE TEST RESULTS FROM
									
... technician to assume that a stator winding has high levels of PD, when in fact the high levels are caused by the noise. The consequence is that a good winding may be incorrectly assessed as being defective – that is a false alarm may be given that a winding is bad, when it is not. Such false alarms ...
                        	... technician to assume that a stator winding has high levels of PD, when in fact the high levels are caused by the noise. The consequence is that a good winding may be incorrectly assessed as being defective – that is a false alarm may be given that a winding is bad, when it is not. Such false alarms ...
									AC Meters - UniMAP Portal
									
... •Actually, the circuit would probably be designed for fullscale deflection with a 10V rms AC applied, which means the multiplier resistor would be only 45% of the value of the multiplier resistor for 10V dc voltmeter. Since we have seen that the equivalent dc voltage is equal to 45% of the rms value ...
                        	... •Actually, the circuit would probably be designed for fullscale deflection with a 10V rms AC applied, which means the multiplier resistor would be only 45% of the value of the multiplier resistor for 10V dc voltmeter. Since we have seen that the equivalent dc voltage is equal to 45% of the rms value ...
									MX-2002(E)
									
... MX-2002: Six-zone, 24 volt Agent Release Control Panel (includes backbox, power supply, technical manual, and a frame & post operating instruction sheet) for single and dual hazard agent releasing applications. MX-2002E: Same as above but allows connection to 220/240 ...
                        	... MX-2002: Six-zone, 24 volt Agent Release Control Panel (includes backbox, power supply, technical manual, and a frame & post operating instruction sheet) for single and dual hazard agent releasing applications. MX-2002E: Same as above but allows connection to 220/240 ...
									High-efficiency, high step-up DC-DC converters
									
... concern is the severe reverse-recovery problem that occurs in the output rectifier due to the high output voltage. The boost and buck–boost converters are the simplest nonisolation topologies. Unfortunately, the switch sustaining the high output voltage has a high - . Furthermore, the short pulse cu ...
                        	... concern is the severe reverse-recovery problem that occurs in the output rectifier due to the high output voltage. The boost and buck–boost converters are the simplest nonisolation topologies. Unfortunately, the switch sustaining the high output voltage has a high - . Furthermore, the short pulse cu ...
									Schmitt trigger package
									
... Assume that the power supply voltages for the op-amp are +Vs and that the op-amp output saturates at the supply voltages. If the input voltage is Vin, calculate the formula for the voltage at the non-inverting input of the op-amp when:(i) the output of the op-amp is saturated positively. ...
                        	... Assume that the power supply voltages for the op-amp are +Vs and that the op-amp output saturates at the supply voltages. If the input voltage is Vin, calculate the formula for the voltage at the non-inverting input of the op-amp when:(i) the output of the op-amp is saturated positively. ...
									STP52N25M5
									
... MOSFET based on an innovative proprietary vertical process technology, which is combined with STMicroelectronics’ well-known PowerMESH™ horizontal layout structure. The resulting product has extremely low onresistance, which is unmatched among siliconbased Power MOSFETs, making it especially suitabl ...
                        	... MOSFET based on an innovative proprietary vertical process technology, which is combined with STMicroelectronics’ well-known PowerMESH™ horizontal layout structure. The resulting product has extremely low onresistance, which is unmatched among siliconbased Power MOSFETs, making it especially suitabl ...
									MAX685 Dual-Output (Positive and Negative), DC-DC Converter for CCD and LCD General Description
									
... The MAX685 DC-DC converter accepts an input voltage between +2.7V and +5.5V and generates both a positive and negative voltage, using a single inductor (Figure 1). It alternates between acting as a step-up converter and as an inverting converter on a cycle-by-cycle basis. Both output voltages are in ...
                        	... The MAX685 DC-DC converter accepts an input voltage between +2.7V and +5.5V and generates both a positive and negative voltage, using a single inductor (Figure 1). It alternates between acting as a step-up converter and as an inverting converter on a cycle-by-cycle basis. Both output voltages are in ...
									osc/INTELLIMETER - Standard Energy Systems, Inc.
									
... Register is integrated into a remote reading system with the pulse output a periodic check for help messages is advisable. Repairs: It is not recommended that the field personnel replace any of the Register’s internal components, including fuses. If it is necessary to replace an Intellimeter Registe ...
                        	... Register is integrated into a remote reading system with the pulse output a periodic check for help messages is advisable. Repairs: It is not recommended that the field personnel replace any of the Register’s internal components, including fuses. If it is necessary to replace an Intellimeter Registe ...
									User Manual VME64x 7U
									
... electrostatic discharge (ESD). Make sure that the temperature does not exceed the operating temperature given in the environmental requirements in this guide and allow room for proper air flow for cooling. ...
                        	... electrostatic discharge (ESD). Make sure that the temperature does not exceed the operating temperature given in the environmental requirements in this guide and allow room for proper air flow for cooling. ...
Variable-frequency drive
                        A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.