SPS12D100NB - Plasmatronics
... A comprehensive set of alarms is provided. Seven user definable alarm inputs are provided as well as the internally generated alarms. Six of these are available via voltage-free relay contact pairs. For more accurate remote control and monitoring, a serial port is available. This allows remote exami ...
... A comprehensive set of alarms is provided. Seven user definable alarm inputs are provided as well as the internally generated alarms. Six of these are available via voltage-free relay contact pairs. For more accurate remote control and monitoring, a serial port is available. This allows remote exami ...
Step-up Transformers - Pacific Crest Transformers
... The role of step-up transformers in the industrial market is extremely important since their performance can directly impact the entire electrical supply of the operation. To guard against the possibility of an extended disruption in power supply for critical operations, the use of a back-up power s ...
... The role of step-up transformers in the industrial market is extremely important since their performance can directly impact the entire electrical supply of the operation. To guard against the possibility of an extended disruption in power supply for critical operations, the use of a back-up power s ...
BO36390397
... operating modes is shown in Figure 6. The main components of DSTATCOM are – a VSC (voltage source converter), controller, filter, and energy storage device. The system scheme of DSTATCOM is shown in Figure 5. These are briefly described as follows: A. Isolation transformer: It connects the DSTATCOM ...
... operating modes is shown in Figure 6. The main components of DSTATCOM are – a VSC (voltage source converter), controller, filter, and energy storage device. The system scheme of DSTATCOM is shown in Figure 5. These are briefly described as follows: A. Isolation transformer: It connects the DSTATCOM ...
Compleet aanbod LED-producten Une offre complète de
... feature is the ultra-low 0.15pF max capacitance which enables distorting less data signals. In addition to being virtually invisible to the circuit during normal operation, the variable voltage polymer technology turns on in less than one nanosecond during an ESD event, and ensures protection of all ...
... feature is the ultra-low 0.15pF max capacitance which enables distorting less data signals. In addition to being virtually invisible to the circuit during normal operation, the variable voltage polymer technology turns on in less than one nanosecond during an ESD event, and ensures protection of all ...
FPGA board - ECE Users Pages
... Fig. 3. (a) Programming accuracy of our on-chip I-to-V vs. a commercially available current meter. The increase in error at high currents is due to accuracy of the ADC. During high currents, the output voltage of the I-to-V moves faster than 1LSB change for the ADC. Future versions of the I-to-V wil ...
... Fig. 3. (a) Programming accuracy of our on-chip I-to-V vs. a commercially available current meter. The increase in error at high currents is due to accuracy of the ADC. During high currents, the output voltage of the I-to-V moves faster than 1LSB change for the ADC. Future versions of the I-to-V wil ...
How to Define the LF Driver`s Key Parameters in
... 8MHz resonator. For example, in the case of the ATA5279C device, this fixed frequency is 125kHz. The converter is able to generate an output voltage of up to 40V, providing the required supply voltage for the driver stage. The antenna current regulator provides the required control voltage for the b ...
... 8MHz resonator. For example, in the case of the ATA5279C device, this fixed frequency is 125kHz. The converter is able to generate an output voltage of up to 40V, providing the required supply voltage for the driver stage. The antenna current regulator provides the required control voltage for the b ...
GF2211111118
... during this time period, the system suffers greatest stress from excessive over-currents or voltages which if severe, can cause extensive damage[3,4,5]. Switching transients are more common than any other form of transient . In this paper we try to observe,analyze and compare the effects of capacito ...
... during this time period, the system suffers greatest stress from excessive over-currents or voltages which if severe, can cause extensive damage[3,4,5]. Switching transients are more common than any other form of transient . In this paper we try to observe,analyze and compare the effects of capacito ...
An RF–DC Converter with Wide Dynamic Range Input Matching For
... data transmission will further increase the frequency of utilisation. Highfrequency (HF) is the ITU-designated range of radio frequency electromagnetic waves (radio waves) between 3 and 30 MHz.Also known as the decameter band or decameter wave as the wavelengths range from one to ten decameters (ten ...
... data transmission will further increase the frequency of utilisation. Highfrequency (HF) is the ITU-designated range of radio frequency electromagnetic waves (radio waves) between 3 and 30 MHz.Also known as the decameter band or decameter wave as the wavelengths range from one to ten decameters (ten ...
Open Access proceedings Journal of Physics: Conference series
... electrodes influences the measurement result only negligibly [4]. If the potential difference between both single monitor electrodes and the bulk electrolyte is equal, the measured voltage between the inner electrodes will truly be the voltage drop between the inner electrodes. In this sense, it is ...
... electrodes influences the measurement result only negligibly [4]. If the potential difference between both single monitor electrodes and the bulk electrolyte is equal, the measured voltage between the inner electrodes will truly be the voltage drop between the inner electrodes. In this sense, it is ...
LP3871/LP3874 0.8-A Fast Ultra-Low Dropout Linear Regulators
... The LP3871and LP3874 devices are short-circuit protected and, in the event of a peak overcurrent condition, the short-circuit control loop will rapidly drive the output PMOS pass element off. Once the power pass element shuts down, the control loop will rapidly cycle the output on and off until the ...
... The LP3871and LP3874 devices are short-circuit protected and, in the event of a peak overcurrent condition, the short-circuit control loop will rapidly drive the output PMOS pass element off. Once the power pass element shuts down, the control loop will rapidly cycle the output on and off until the ...
euramot - Specification Type DC..../N
... Machine run blockage effective with open contact Machine run blockage effective with closed contact Machine run blockage effective with open contact (unpositioned) Machine run blockage effective with closed contact unpositioned) Run at automatic speed n12 Run at limited speed n12 Sewing foot lift wi ...
... Machine run blockage effective with open contact Machine run blockage effective with closed contact Machine run blockage effective with open contact (unpositioned) Machine run blockage effective with closed contact unpositioned) Run at automatic speed n12 Run at limited speed n12 Sewing foot lift wi ...
ADF7023-J (Rev. 0)
... The RC oscillator can be used to control the wake-up timing of the ADF7023-J low power modes. Its typical accuracy is specified as 1.5% after a calibrat ion at 25°C. The calibration range of the RC oscillator is not sufficient to ensure a 1.5% typical accuracy on all devices. This can result in the ...
... The RC oscillator can be used to control the wake-up timing of the ADF7023-J low power modes. Its typical accuracy is specified as 1.5% after a calibrat ion at 25°C. The calibration range of the RC oscillator is not sufficient to ensure a 1.5% typical accuracy on all devices. This can result in the ...
MAX15050/MAX15051 High-Efficiency, 4A, 1MHz, Step-Down Regulators General Description
... The MAX15050/MAX15051 high-efficiency switching regulators deliver up to 4A load current at output voltages from 0.6V to (0.9 x VIN). The devices operate from 2.9V to 5.5V, making them ideal for on-board point-of-load and postregulation applications. Total output-voltage accuracy is within ±1% over ...
... The MAX15050/MAX15051 high-efficiency switching regulators deliver up to 4A load current at output voltages from 0.6V to (0.9 x VIN). The devices operate from 2.9V to 5.5V, making them ideal for on-board point-of-load and postregulation applications. Total output-voltage accuracy is within ±1% over ...
Planning of an electric system for a small CNC machine Thesis
... The goal of the project is to make a small form-factor CNC milling machine, which should be portable enough to be carried by a person or two. The machine will have three linear servo driving mechanisms, each perpendicular to each other, to form X, Y and Z axes. The outer dimensions were estimated to ...
... The goal of the project is to make a small form-factor CNC milling machine, which should be portable enough to be carried by a person or two. The machine will have three linear servo driving mechanisms, each perpendicular to each other, to form X, Y and Z axes. The outer dimensions were estimated to ...
Paper Title (use style: paper title)
... Triggered solid state devices capable of holding off more than 1 kV and surging multiple kAs of current are increasingly a viable alternative for pulsed power applications that previously required triggered spark gap switches or other devices based on gaseous electronics. For a number of pulsed appl ...
... Triggered solid state devices capable of holding off more than 1 kV and surging multiple kAs of current are increasingly a viable alternative for pulsed power applications that previously required triggered spark gap switches or other devices based on gaseous electronics. For a number of pulsed appl ...
Slide 1
... In various kinds of analog to digital converters, and in many digital circuits, diodes are extensively brought to use. Their primary domain of operation is switching, i.e., to keep a portion of a large circuit in the ON state, selectively for a given interval of time. They, in coherent action w ...
... In various kinds of analog to digital converters, and in many digital circuits, diodes are extensively brought to use. Their primary domain of operation is switching, i.e., to keep a portion of a large circuit in the ON state, selectively for a given interval of time. They, in coherent action w ...
Reducing Losses Using Windmil
... • Increase in net kVAR means an increase in kVA and current levels on the system – Available capacity on equipment decreases – Equipment sizes come into question if they were sized only on kW – Line losses increase (I2R) ...
... • Increase in net kVAR means an increase in kVA and current levels on the system – Available capacity on equipment decreases – Equipment sizes come into question if they were sized only on kW – Line losses increase (I2R) ...
FAN6749 Highly Integrated Ultra Green-Mode PWM Controller Features
... minimum line filters. Built-in synchronized slope compensation helps achieve stable peak-current control. To keep constant output power limit over universal AC input range, the current limit and OCP threshold voltage are adjusted according to AC line voltage detected by the HV pin. Gate output is cl ...
... minimum line filters. Built-in synchronized slope compensation helps achieve stable peak-current control. To keep constant output power limit over universal AC input range, the current limit and OCP threshold voltage are adjusted according to AC line voltage detected by the HV pin. Gate output is cl ...
Variable-frequency drive
A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.