• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Integrating Bourns® Resistive Products to Control Current and
Integrating Bourns® Resistive Products to Control Current and

... supply voltage is slightly greater than the load voltage, a linear current supply may be incorporated in the design. In the case of a linear supply, current is limited by a resistor. A switching supply, available for a range of voltages, is more efficient than a linear supply and generates less heat ...
TPS7A30 –35-V, –200-mA, Ultralow
TPS7A30 –35-V, –200-mA, Ultralow

... safeguard the device and system during fault conditions. The TPS7A30 family is designed using bipolar technology, and is ideal for high-accuracy, highprecision instrumentation applications where clean voltage rails are critical to maximize system performance. This design makes the device an excellen ...
Maximum Energy Harvesting Control Foroscillating Energy
Maximum Energy Harvesting Control Foroscillating Energy

... oscillator is the basis of the energy harvesting backpack, as the energy removed from the system will be converted to electricity. If one were to design the system with the goal of minimizing the net energy expelled by the user, it would be ideal to design the DDHO to minimize the change in height o ...
MAX3316–MAX3319 2.5V, 1µA, 460kbps, RS-232-Compatible Transceivers General Description
MAX3316–MAX3319 2.5V, 1µA, 460kbps, RS-232-Compatible Transceivers General Description

... low-dropout transmitter output stage enabling RS-232compatible performance from +2.25V to +3.0V with a dual-charge pump. These devices require only four 0.1µF capacitors, and are guaranteed to operate at data rates up to 460kbps. The MAX3318/MAX3319 achieve a 1µA supply current using Maxim’s revolut ...
Vcc + Vss - Renesas E
Vcc + Vss - Renesas E

... • Learn how the common-mode noise reduction technique can be applied to LSI packages and circuit board power distribution lines. Content • 17 pages Learning Time 30 minutes ...
BY 240 / BY 840
BY 240 / BY 840

... In this operation mode, the trim inputs operate as edge triggered impulse inputs and each negative transition will displace the slave shaft position exactly by one encoder impulse (Trim+ = forward, Trim- = reverse). This function allows, for example, a PLC control to step the phase to different, ful ...
KA79MXX / LM79MXX 3-Terminal 0.5 A Negative Voltage Regulator KA79MXX /
KA79MXX / LM79MXX 3-Terminal 0.5 A Negative Voltage Regulator KA79MXX /

... 4. To specify an output voltage, substitute voltage value for "XX". 5. CI is required if the regulator is located an appreciable distance from the power supply filter. For value given, capacitor must be solid tantalum. If aluminium electronics are used, 25 μF aluminum electrolytic may be substituted ...
MAX5915/MAX5915A/MAX5916/MAX5916A Dual PCI 2.2 Hot-Swap Controllers General Description Features
MAX5915/MAX5915A/MAX5916/MAX5916A Dual PCI 2.2 Hot-Swap Controllers General Description Features

... PCI 2.2 hot-swap controllers allow for safe insertion and removal of two PCI cards into live PCI slots or backplanes by limiting the inrush current at startup. After startup, these devices provide protection against shortcircuit, overcurrent, and undervoltage conditions. The MAX5915/MAX5915A/MAX5916 ...
HMStv Manual - SilverLeaf Electronics
HMStv Manual - SilverLeaf Electronics

... Highlight and select “START GENERATOR”. The generator will automatically go through it’s prime cycle and start up. The generator internal operation readouts are on this page giving AC Output Voltage, Frequency, Load %, Generator RPM’s, Runtime, and Internal Temperature. To Stop The Generator: Highli ...
MAX3232E-Q1 数据资料 dataSheet 下载
MAX3232E-Q1 数据资料 dataSheet 下载

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
YASKAWA AC Drive-Option Card Encoder Type (EnDat) Installation
YASKAWA AC Drive-Option Card Encoder Type (EnDat) Installation

A 35 fJ 10b 160 MS/s Pipelined-SAR ADC with Decoupled Flip
A 35 fJ 10b 160 MS/s Pipelined-SAR ADC with Decoupled Flip

HIN202, HIN206, HIN207, HIN208, HIN211, HIN213
HIN202, HIN206, HIN207, HIN208, HIN211, HIN213

... voltage doubler and the voltage inverter. Each section is driven by a two phase, internally generated clock to generate +10V and -10V. The nominal clock frequency is 125kHz. During phase one of the clock, capacitor C1 is charged to VCC . During phase two, the voltage on C1 is added to VCC , producin ...
AT 121 - Chapter 2 - Basic Electrical Principals
AT 121 - Chapter 2 - Basic Electrical Principals

... On Car Starter Motor Inspection – Customer Complaint – “Poor Crank, or Intermittent Crank” If a starter does not run, and the battery checks out, this simple test may be preformed on any vehicle. The test is broken down to inspect the most basic parts of a starter circuit. Proper power and ground ...
Programmable Logic Controllers
Programmable Logic Controllers

... • Can use visible, ultraviolet, infrared, or laser lights. • Require both an emitter to generate the light beam and a detector. • Modern versions are very sophisticated and can even detect the type of object. ...
MAX13051 ±80V Fault-Protected Can Transceiver with Autobaud General Description
MAX13051 ±80V Fault-Protected Can Transceiver with Autobaud General Description

... with autobaud is ideal for device net and other industrial network applications where overvoltage protection is required. The MAX13051 provides a link between the CAN protocol controller and the physical wires of the bus lines in a control area network (CAN). The MAX13051 features three different mo ...
H CMOS Switches Offer High Performance in Low Power, Wideband Applications
H CMOS Switches Offer High Performance in Low Power, Wideband Applications

... of the switch can modulate the Vg, thereby causing distortion products as the on resistance of the switch varies. The use of high control voltages will reduce this effect, but only at the cost of generating voltages of approximately +2 V to –8 V to control the switches. GaAs processes don’t offer co ...
Aalborg Universitet
Aalborg Universitet

CT235001EN
CT235001EN

... To verify that Eaton’s Cooper Power series deadfront arresters are able to withstand valve block failures without ejecting arrester parts through the body of the housing, in accordance with IEEE Std C62.11™-2005 standard, Paragraph 8.20. Procedures: ...
ppt - kaliasgoldmedal
ppt - kaliasgoldmedal

... • 3 Phase Fully Controlled Full Wave Bridge Converter. • Known as a 6-pulse converter. • Used in industrial applications up to 120kW output power. ...
Shaft Alternator Systems
Shaft Alternator Systems

... Circuit diagram with shaft alternator directly in the propeller shaft line: 1 shaft alternator, 2 shaft alternator excitation, 3 diode rectifier top-mounted on the shaft alternator, 4 integrated over voltage protection chopper, 5 PWM inverter, 6 LCL line filter, 7 auxiliary power supply, 8 PWM excit ...
Renewables: Wind
Renewables: Wind

... modern wind turbine generators, mainly through modifications of the turbine generator controls. • Power curtailment and ramping: Power curtailment and ramping can be achieved through unit active-stall or pitch control, and/or discrete tripping of individual units. • Primary frequency regulation: Pri ...
MAX5974A Evaluation Kit Evaluates: General Description Features
MAX5974A Evaluation Kit Evaluates: General Description Features

Reset Circuit Applications in the HT66Fx0 Series MCU
Reset Circuit Applications in the HT66Fx0 Series MCU

... external application circuits, the MCU itself also contains a power-on reset (POR) and low voltage reset (LVR) circuits. The POR circuit includes a low RC time constant reset circuit with power-on reset function. The internal MCU initialization status is the same as the RESB reset except for the cle ...
S280-79-1
S280-79-1

... Figure 3. Line current flowing through the recloser is converted by the CPU module to a digital signal suitable for metering and fault current calculations. Data sampling occurs at a rate 32 times per cycle. The CPU contains a data acquisition section that uses the acquired samples to compute the fu ...
< 1 ... 153 154 155 156 157 158 159 160 161 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.