• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SmartFusion cSoC: DC Fan Control Using PWM
SmartFusion cSoC: DC Fan Control Using PWM

General Calculations Excerpt from PRYSMIAN`S
General Calculations Excerpt from PRYSMIAN`S

... one hour. Also, they may be used when additional insulation strength over the 100 percent level category is desirable. 173 Percent Level - Cables in this category should be applied on systems where the time required to de-energize a grounded section is indefinite. Their use is recommended also for r ...
Penn Foster`s Michigan Electrical Apprenticeship program
Penn Foster`s Michigan Electrical Apprenticeship program

... A thorough knowledge of safe practices is an important part of working in any industrial setting. Every industrial worker should be familiar with accident prevention techniques, fire safety mehods, and the use of personal protective equipment. Injuries in the workplace cost many millions of dollars ...
Chopper-Stabilized Bidirectional Current Acquisition Circuits for
Chopper-Stabilized Bidirectional Current Acquisition Circuits for

SECTION 16410
SECTION 16410

... modules of the same size operating in parallel. All modules shall be operating and sharing the load. The system shall be redundant. The system shall have one additional module than that required to supply the full rated load. The failure of any one of the modules shall cause that module be disconnec ...
A Low-Power, Process-and-Temperature
A Low-Power, Process-and-Temperature

... Designs of process and temperature compensated ring oscillators with moderate frequency accuracy (between 1% and 10%) have been explored in the past. One technique introduced by Chen et al. is based on a PLL structure with external off-chip frequency [14]. Another recently proposed technique for emb ...
Overcurrent Protection: Fuses and Circuit Breakers
Overcurrent Protection: Fuses and Circuit Breakers

SP3239E 数据资料DataSheet下载
SP3239E 数据资料DataSheet下载

... convert TTL or CMOS logic levels to 5.0V EIA/ TIA-232 levels with an inverted sense relative to the input logic levels. Typically, the RS-232 output voltage swing is +5.4V with no load and +5V minimum fully loaded. The driver outputs are protected against infinite short-circuits to ground without de ...
Trombetta Product Guide 2014
Trombetta Product Guide 2014

... Flat On Base Flat On Base Flat On Side Flat On Side Flat On Base Flat On Base Flat On Side Flat On Side ...
FPF1005-FPF1006 IntelliMAX Advanced Load Management Products F
FPF1005-FPF1006 IntelliMAX Advanced Load Management Products F

... A 0.1µF capacitor, COUT, should be placed between VOUT and GND. This capacitor will prevent parasitic board inductance from forcing VOUT below GND when the switch turns-off. Due to the integral body diode in the PMOS switch, a CIN greater than COUT is highly recommended. A COUT greater than CIN can ...
(ECE 405 - ECE 406)
(ECE 405 - ECE 406)

ZXRE060 0.6V ADJUSTABLE PRECISION SHUNT REGULATOR
ZXRE060 0.6V ADJUSTABLE PRECISION SHUNT REGULATOR

DAC8532 - Farnell
DAC8532 - Farnell

... be as high as 30MHz, making the DAC8532 compatible with high speed DSPs. On the 24th falling edge of the serial clock, the last data bit is clocked into the shift register and the programmed function is executed (i.e., a change in Data Buffer contents, DAC Register contents, and/or a change in the p ...
PAM8010 Description Pin Assignments
PAM8010 Description Pin Assignments

... At this stage it is paramount to notice the necessity of separate grounds. Noise currents in the output power stage need to be returned to output noise ground and nowhere else. Were these currents to circulate elsewhere, they may get into the power supply, the signal ground, etc, worse yet, they may ...
Low-Drift Bidirectional Low-Side Current
Low-Drift Bidirectional Low-Side Current

DRT Series
DRT Series

... operating efficiency of the producion equipment. With this information a maintenance system can be fed with information to schedule preventive maintenence actions. This will reduce machine downtime caused by unscheduled repairs during production. The control system and the maintenance system both us ...
RD-3x Dytronic Energy Reference Standard
RD-3x Dytronic Energy Reference Standard

... The RD-3x incorporates Radian’s patented Dytronic measurement technology consisting of a Radian designed Integrating Analog to Digital Signal Converter. Unlike off-the-shelf A/D converters used in similar instruments, Radian’s A/D Converter is specifically designed and optimized for power and energy ...
DS1831C/D/E 3.3V/2.5V Multisupply MicroMonitor FEATURES PIN ASSIGNMENT
DS1831C/D/E 3.3V/2.5V Multisupply MicroMonitor FEATURES PIN ASSIGNMENT

... diagram and sample equations. The equations demonstrate a design process to determine the resistor values to use. Connecting one or both NMI outputs to one of the reset specific PBRST s allows the non-maskable interrupt to generate an automatic reset for the reset time period when an out-of-toleranc ...
LED OSRAM 12v - geplastcommunication.it
LED OSRAM 12v - geplastcommunication.it

FFP08H60S 8 A, 600 V, Hyperfast II Diode F
FFP08H60S 8 A, 600 V, Hyperfast II Diode F

... No Identification Needed ...
Inputs Currents for High-Resolution ADCs
Inputs Currents for High-Resolution ADCs

±15kV ESD-Protected, 1µA, 3.0V to 5.5V, 250kbps, RS-232 Transceivers with AutoShutdown
±15kV ESD-Protected, 1µA, 3.0V to 5.5V, 250kbps, RS-232 Transceivers with AutoShutdown

... supply current with Maxim’s new AutoShutdown feature, which operates when FORCEON is low and FORCEOFF is high. When these devices sense no valid signal levels on all receiver inputs for 30µs, the onboard charge pump and drivers are shut off, reducing supply current to 1µA. This occurs if the RS-232 ...
North Yaran Oil Field Development
North Yaran Oil Field Development

... 50 KA for Main LV switchgear and motor control center 6.4 In general, all supply feeders and transformers shall be designed and sized with 20% spare capacity to cater for future loads. ...
Solar Electric Installation Requirements
Solar Electric Installation Requirements

Excalibur Chip Set Controller
Excalibur Chip Set Controller

< 1 ... 106 107 108 109 110 111 112 113 114 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.