• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Fusion Datasheet.indd - Control Concepts, Inc.
Fusion Datasheet.indd - Control Concepts, Inc.

... UL Mark is less than 3/8 of an inch, the trademark symbol may be omitted if it is not legible to the naked eye. The font for all letter forms is Helvetica Condensed Black, except for the trademark symbol ®, which is Helvetica Condensed Medium. No other fonts are acceptable. 200-195C 20M/11/97 ...
Differentiator
Differentiator

Motor Management of Permanent Magnet Synchronous Machines
Motor Management of Permanent Magnet Synchronous Machines

... the magnetic field in the machine – this is the field weakening range. In induction and electrically excited synchronous machines this measure is performed by reducing the field current. In permanent magnet synchronous machines, the permanent magnets cannot be switched off. In order to yet operate t ...
sheet3
sheet3

BDTIC
BDTIC

... photovoltaic modules and the grid. For this reason, an extra circuitry is recommended in order to protect the battery bank from any overvoltage coming from the grid, for instance from lightning. This can be implemented for example by fuses connected to the positive and/or negative terminal of the ba ...
AMC6821 E2E Question
AMC6821 E2E Question

... still run properly even after I2C communication is terminated. Any help would be greatly appreciated. ...
Shunt Active Power Filter for Harmonic Mitigation by
Shunt Active Power Filter for Harmonic Mitigation by

Evolis 24 kV Lateral version
Evolis 24 kV Lateral version

... Phase to phase distance (mm) MV connection on the: Ud 50 kV 50 Hz, 1 min 12.5 kA Up 125 kV peak 16 kA Lateral version - MV connection on the right 20 kA ...
EXP4: Tie Line Scheduling
EXP4: Tie Line Scheduling

... Tie-line allow the sharing of generation resources in emergencies and economies of power production under normal conditions of operation. For the purpose of controlling the entire interconnected system, the system will be divided into control areas. which usually conform to the boundaries of one or ...
Auxiliary Devices for Sure Operation
Auxiliary Devices for Sure Operation

... to a distant amplifier via a shielded extension cable consisting of 4 conductors (0.75mm2) or 6 conductors (1.25mm2). The JBS-1CSA is also available for use in explosive environments. ...
功率变换
功率变换

... From the Socket to the Pocket and Soft-Skip are trademarks of SCILLC. *Blue Angel, ENERGY STAR, CECP, Intusoft and all other brand names and logos are registered trademarks or trademarks of their respective holders. ON Semiconductor and the ON logo are registered trademarks of Semiconductor Componen ...
MD1803DFP
MD1803DFP

... Figure 12. Power losses and inductive load switching test circuit ...
Tutorial 2 Rectifier
Tutorial 2 Rectifier

RD-021M8
RD-021M8

... ◇The voltage/current of the input/output terminals conforms to the ratings in the specifications. ◇Input/output terminals are not incorrectly wired or accidentally short-circuited. ◇Do not short resistance terminals (R-A and R-B) to GND. ◇Do not use with the motor except the stepping motor. ◇Operate ...
product specificatie SMX1200LHG logo
product specificatie SMX1200LHG logo

... Less than 4.5 hours from 10% to 90% ...
Optical isolator:
Optical isolator:

... LED-based optical couplers were one of the first techniques applied to the isolation design problem. Several LED-based ICs are now available and can supply data speeds of 10 Mbps and beyond. An important design consideration is an LED’s decreased light output with age. You must therefore supply exce ...
Alarm Unit with Current and Voltage Input and Double Relay
Alarm Unit with Current and Voltage Input and Double Relay

... Input / power supply / relay outputs Relay 1 / Relay 2 Power supply Voltage ...
2 Reference Design
2 Reference Design

display
display

... Most DC motor driver boards are advertised as 12, 24 or even 48 volts. That means that if you buy a board rated for 24 volts, it won't work on 12 volts and if you try to run it on 48 volts, it might be destroyed. Not the D200, the D200 can be used on applications where the motor B + can be of ANY vo ...
T4400 Load Sharer
T4400 Load Sharer

... ­important to ensure that the phase ­sequence is correct. This relation between the connections of voltage and current must be correct in order to achieve a correct load measure­ ment. It can be checked on terminal 11 (TEST OUT), where an input of nominal current (1A or 5A) and power factor 1.0 give ...
DC Current Transducer DK-B420 I = 150 .. 400 A
DC Current Transducer DK-B420 I = 150 .. 400 A

... When operating the transducer, certain parts of the module may carry hazardous live voltage (eg. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electical shock. The transducer is a build-in device containing conducting parts that shall not b ...
Impact on power system by stationary fuel cell applications
Impact on power system by stationary fuel cell applications

... a power factor of 0.95 and an induction motor with a rating of 7.0 kW for continuous duty. The applied load torque at the induction machine represents a compressor or a pump, that means a square-law load torque depending on number of revolutions of motor [5]. The micro-grid may be operated in parall ...
ultravolt® v series vertical, micro-sized high voltage biasing supplies
ultravolt® v series vertical, micro-sized high voltage biasing supplies

Introduction to Using Hybrid-Electric Vehicle Technology with
Introduction to Using Hybrid-Electric Vehicle Technology with

... Even though lithium-ion batteries have a higher energy density, they are almost eight times more expensive than the lead-acid. However, the lithium-ion has three times more energy per kilogram than the lead-acid, meaning it packs more energy per size. Lead-acid batteries are more readily available t ...
Mr. Sarver Review Questions 16 The current will flow only as long as
Mr. Sarver Review Questions 16 The current will flow only as long as

... not turn, it may hum for a little while, but eventually it will produce smoke and melt the coatings on the windings and maybe even catch fire. • Suppose you secure both of the hot wires from the 220V machine to the one hot wire from the 110V circuit and of course the neutral and ground to their wire ...
< 1 ... 1051 1052 1053 1054 1055 1056 1057 1058 1059 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report