• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electronics Lab Work Sheet
Electronics Lab Work Sheet

memorias descriptivas
memorias descriptivas

Harmonic Analysis of 6-Pulse and 12-Pulse Converter Models
Harmonic Analysis of 6-Pulse and 12-Pulse Converter Models

... The transmission and distribution of electrical energy Started with direct current (DC) in late 19th century, but it was inefficient due to the power loss in conductors. Alternating current (AC) offered much better efficiency, since it could easily be transformed to higher voltages, with far less lo ...
ha0220T_7_LD_Scanning Galvo System.fm
ha0220T_7_LD_Scanning Galvo System.fm

... controller board(s) as this power supply has been specifically designed for this purpose. The GPS011 can power up to two driver cards under any drive conditions and is supplied with all the cables required to connect to the driver cards. However, customers also have the option of using a third-party ...
Ledex® Drive Electronics and Coil Suppressors
Ledex® Drive Electronics and Coil Suppressors

... A voltage is generated by a changing magnetic field in proximity to a current-carrying member. The equation E = -Ndø/dt, describes this by saying that the magnitude of the voltage is proportional to the number of turns (N), i.e., of a coil, and the rate of change of a magnetic field. This theory can ...
Synchronous operation of five-phase converters in linear modulation
Synchronous operation of five-phase converters in linear modulation

... standard space-vector modulation are based on asynchronous principle, which results in subharmonics (of the fundamental frequency) in the spectrum of the output voltage of inverters, that are very undesirable in drive systems with increased power rating, operating at low switching frequencies [10],[ ...
Preparation of Papers in Two-Column Format for the
Preparation of Papers in Two-Column Format for the

... Fig. 2 Available voltage in the different states of the duty and different points of the supply wave ...
Faraday`s Law and the Genecon
Faraday`s Law and the Genecon

... In this lab we will further explore the phenomena associated with magnets and coils of wire. A generator is a device which uses relative motion between wires and magnetic fields. The voltage output of a DC generator such as the Genecon can be written as: V() = 0.707NBA. where  is the rotational ...
1- A resistor is a device. It adds resistance to a circuit . BY
1- A resistor is a device. It adds resistance to a circuit . BY

... electromagnetic torque on the magnetic field of the rotor. The rotor moves around a ...
Determination of Rotor Slot Number of an Induction Motor Using an
Determination of Rotor Slot Number of an Induction Motor Using an

History of HVDC transmission
History of HVDC transmission

SINGLE PHASE PWM RECTIFIER IN TRACTION APPLICATION
SINGLE PHASE PWM RECTIFIER IN TRACTION APPLICATION

Lab-3
Lab-3

Rarely Asked Questions (Observing Maximum Ratings or How to
Rarely Asked Questions (Observing Maximum Ratings or How to

... is never stated. Some devices are very robust, some are not, but no manufacturer will provide support for deviation from the limits. The only safe rule is to treat “never” as never. But understanding why exceeding absolute maximum limits can cause damage allows us to design better systems. A zener d ...
AC to DC Converter (Rectifier)
AC to DC Converter (Rectifier)

... load current, thyristors T1 and T2 remain in the on-state beyond the positive half-wave of the source voltage vs . For this reason, the load voltage vd can have a negative instantaneous value. value The firing of thyristors T3 and T4 has two effects: i) they turn off thyristors T1 and T2; and ii) af ...
Future applications based on the data provided by next generation
Future applications based on the data provided by next generation

L293, L293D Quadruple Half-H Drivers (Rev. D)
L293, L293D Quadruple Half-H Drivers (Rev. D)

... The L293 and L293D are quadruple high-current half-H drivers. These devices are designed to drive a wide array of inductive loads such as relays, solenoids, DC and bipolar stepping motors, as well as other high-current and high-voltage loads. All inputs are TTL compatible and tolerant up to 7 V. Eac ...
comparative study of different control strategies for
comparative study of different control strategies for

UCI224G
UCI224G

... of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request. VOLTAGE REGULATORS SX460 AVR - STANDARD With this self excited control system the main stator supplies power via the Automatic Voltag ...
Power Output
Power Output

CDR  - University of Colorado Boulder
CDR - University of Colorado Boulder

EE 1424752
EE 1424752

... multiple of fifth harmonics are absent i.e. higher order harmonic gets eliminated, as number of phases are increased current in each phase is reduced therefore stress on each switch is less so life of switch get increased. The high phase order drive is likely to remain specialized applications where ...
Solid State Relays Accessories.POWER Type RV
Solid State Relays Accessories.POWER Type RV

... • Transient protection devices for Solid State Relays ...
Digital OLTC Voltage Controller TAPCON® 250
Digital OLTC Voltage Controller TAPCON® 250

... It is not fused in the controller. Pins TB2.14 & TB2.15 Manual Raise / Lower These terminals provide a connection for external Raise and Lower switches for manual operation. Tap-change operations actuated by external switches will be recognized by the TAPCON®250 if the Raise and Lower Pins (TB1.7 an ...
Quiz #03 ID#: Name:
Quiz #03 ID#: Name:

< 1 ... 1048 1049 1050 1051 1052 1053 1054 1055 1056 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report