• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ApplicationNoteChris..
ApplicationNoteChris..

Products / Fan Controls / Installation Instructions
Products / Fan Controls / Installation Instructions

UNIT - I BASIC MEASUREMENT CONCEPTS PERMANENT
UNIT - I BASIC MEASUREMENT CONCEPTS PERMANENT

...  Instantaneous power: p(t) is the time function of the power, It is the product of the time functions of the voltage and current. This definition of instantaneous power is valid for signals of any waveform. The unit for instantaneous power is VA  Reactive power: Q is the imaginary part of the comp ...
Diode Clamping and Half/Full Wave Signal Rectification Phys 3610/6610 Lab 11 Student: TA:
Diode Clamping and Half/Full Wave Signal Rectification Phys 3610/6610 Lab 11 Student: TA:

... Get one of the lab’s signal generators to generate a 1 kHz 5 V peak-to-peak sine wave. Make sure your sine wave has no DC offset. If you need a transformer to get rid of the DC offset, your TA should have one. Task 1: Rectify the signal using a single 1N4148 diode and a load resistor so that only th ...
Triac dimmable LED lighting solution: Luigi Galioto, Ranajay Mallik, Manoj Kumar ABSTRACT
Triac dimmable LED lighting solution: Luigi Galioto, Ranajay Mallik, Manoj Kumar ABSTRACT

... still maintaining a good LED current accuracy (+/-5%). The device can also provide a constant output voltage regulation (CV): it allows the application to be able to work safely when the LED string opens due to a failure. In addition, the device offers the shorted secondary rectifier (i.e. LED strin ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331

EUP3651  4-Channel, 1X/1.5X Charge Pump White LED Driver
EUP3651 4-Channel, 1X/1.5X Charge Pump White LED Driver

... with lower VF is recommended in order to improve the efficiency by keeping the driver in 1X mode longer as the battery voltage decreases. For example, if a white LED with a VF of 3.3V is selected over one with VF of 3.5V, the EUP3651 will stay in 1X mode for lower supply voltage of 0.2V. This helps ...
WellPilot® Controllers for Rod Pump Optimization
WellPilot® Controllers for Rod Pump Optimization

... Yaskawa U1000 drive. This ac/ac drive enables current to flow both ways through a matrix of nine bidirectional switches—so power generated by the motor during deceleration is sent back to the power supply to be re-used. Because there is no ac/dc conversion, harmonics are exceptionally low and overal ...
345-353 - Ajbasweb..
345-353 - Ajbasweb..

L550A_M5400EX (Page 1)
L550A_M5400EX (Page 1)

... bolt below the voltmeter will flash to indicate an under or over voltage condition. Power to the connected equipment is automatically turned off if either of these conditions is detected. When voltage returns to a safe level, power to the equipment is ...
SPATZ+H9000 High Frequency Inverter Power Source
SPATZ+H9000 High Frequency Inverter Power Source

... frequency. Actual values are compared with target values every 0.025 ms. The output power is adapted during the welding process if targets are not being met. Constant Current Control (CCC), Constant Power Control (CPC) and Constant Voltage Control (CVC) can all be used. At the end of each weld, the ...
Winding Failures of Electrical Motors
Winding Failures of Electrical Motors

Definitions for Electric Service
Definitions for Electric Service

... wires or equipment. Service Disconnect is a customer-owned circuit breaker or fused switch and accessories that is intended to disconnect the customer’s service. ...
Starter Service
Starter Service

... – Starter spins but does not engage – Excessive noise ...
DESIGN, FABRICATION AND CHARACTERIZATION OF A PIEZOELECTRIC
DESIGN, FABRICATION AND CHARACTERIZATION OF A PIEZOELECTRIC

... electrical energy. We implement these devices using microfabrication techniques. These MEMS power generators deliver very small powers (in the nW range) at voltages often inferior to 200mV. To overcome the problem of rectification of such weak amplitude AC signals we designed and fabricated diodes w ...
SMU-DDE-Assignments-Scheme of Evaluation PROGRAM Bachelor
SMU-DDE-Assignments-Scheme of Evaluation PROGRAM Bachelor

...  However, as compared to full-wave rectifiers, half-wave rectifiers create extreme ripple and much more filtering is required to remove harmonics of the AC frequency from the output.  The diode is forward biased as the anode is positive with respect to the cathode during each positive half cycle o ...
Continuous-Time Digital Signal Processing Based
Continuous-Time Digital Signal Processing Based

www.wineyard.in Technical Specifications: Title of the project
www.wineyard.in Technical Specifications: Title of the project

this PDF file - Transaction Series on Engineering
this PDF file - Transaction Series on Engineering

... The conversion is made of H-N series connection. The number of levels generated in the network is equal to 2N + 1. The H convertors are connected to each other from the AC terminals. For example, if three H exchangers are used, the voltage on the network will have 7 levels. The H exchanger is called ...
ECP 11-0212 Electromagnetic Voltage Transformer Test Form
ECP 11-0212 Electromagnetic Voltage Transformer Test Form

Form 6-LS Recloser Control Distribution Protection
Form 6-LS Recloser Control Distribution Protection

miniature, i/o proportional high voltage power supplies
miniature, i/o proportional high voltage power supplies

... in a compact PCB mount package. The isolated output is directly proportional to the input, and is linear from approximately 0.7 volts in. Excellent filtering techniques and a low noise quasi-sinewave oscillator provide clean, reliable DC to HV DC conversion with low ripple, and low EMI/RFI. The isol ...
Power Quality Improvement through Unified power quality
Power Quality Improvement through Unified power quality

ATE1120: Electrical Fundamental-II
ATE1120: Electrical Fundamental-II

... DC motors as shown in Figure 2.2 consist of one set of coils, called armature winding, inside another set of coils or a set of permanent magnets, called the stator. Applying a voltage to the coils produces a torque in the armature, resulting in motion. The main parts of the DC motor are : 1. STATOR: ...
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave

... 99% line-mode efficiency, 2 switched load banks USB, RS232, EPO and slot for SNMPWEBCARD option 120V NEMA 5-15P input, 6 NEMA 5-15R outlets This product is ENERGY STAR qualified for its ability to save ...
< 1 ... 1044 1045 1046 1047 1048 1049 1050 1051 1052 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report