• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
L05016Ci LED Driver 20W, 3-43 Vdc, 1x 110-500 mA
L05016Ci LED Driver 20W, 3-43 Vdc, 1x 110-500 mA

... the 0/1-10V controller delivers (or allows) a voltage that is higher than 12V. The voltage triggers the driver in to ‘pulse switch mode’. This will result in unexpected and unintended behavior of the LED’s. In case of symptoms like these, it is sufficient to clamp the output of the control system wi ...
analog communication trainers
analog communication trainers

Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers

... The thyristor-controlled power supplies and battery chargers present the conventional method of rectifying and controlling electric power. The advantages of thyristor-controlled units are given by a simple technical concept resulting in robustness and reliability. Typical applications ...
Phoenix Plus - Barron Lighting Group
Phoenix Plus - Barron Lighting Group

... 2400 - 4200 watt, single phase output unit uses the latest technology to provide the most advanced performance and reliability features. INPUT 120, 208, 240, 277 or 480 VAC input. AC Input Characteristics: • Input Frequency: 60 Hz • Power walk-in: 0 to 100% over a 10-second period. • Magnetizing Inr ...
4 ES46 LINEAR IC`s AND APPLICATIONS
4 ES46 LINEAR IC`s AND APPLICATIONS

AD8629S: Zero-Drift, Single-Supply Rail-to-Rail Input/Output Operational Amplifier Aerospace Data Sheet (Rev E, 10/2012)
AD8629S: Zero-Drift, Single-Supply Rail-to-Rail Input/Output Operational Amplifier Aerospace Data Sheet (Rev E, 10/2012)

... inputs are maintained within the supply voltages. If one or both inputs could exceed either supply voltage, a resistor should be placed in series with the input to limit the current to less than 5 mA. This ensures that the output does not reverse its phase. 7.4. Overload Recovery Time Many auto-zero ...
to notes
to notes

... power carrying capability using less current. In addition to the increased capacity, higher voltage also results in  Less voltage drop  Decreased losses  Ability to operate over greater distances, thus decreasing the number of substations required to serve a given area. One disadvantage of the gr ...
Power Quality Improvement in 3P4W System Using Unified Power
Power Quality Improvement in 3P4W System Using Unified Power

... transformer is close to the plant under consideration, utility would provide the neutral conductor from this transformer without major cost involvement. In recent cases, this may be a costly solution because the distribution transformer may not be situated in close vicinity. Recently, the utility se ...
NZT660/NZT660A PNP Low Saturation Transistor NZT 660
NZT660/NZT660A PNP Low Saturation Transistor NZT 660

... 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to res ...
Model 482C05 Four-channel, ICP® Sensor Signal Conditioner
Model 482C05 Four-channel, ICP® Sensor Signal Conditioner

... indicates a signal level of +/- 10 V peak has been detected and the signal may be in danger of clipping. These fault lights are active for all channels at the same time. ...
Autotransformer
Autotransformer

... • A 400-turn autotransformer, operating in the step-down mode with a 25% tap, supplies a 4.8-kVA, 0.85 Fp lagging load. The input to the transformer is 2400-V, 60-Hz. Neglecting the small losses and leakage effects, determine – (a) the load current, – (b) the incoming line current, – (c) the transfo ...
Project: sun tracker
Project: sun tracker

Motor Speed Controller
Motor Speed Controller

... When a motor is connected to a fixed voltage it will travel at a set speed. If you reduce the voltage to the motor, the motor’s speed will also be reduced. If the voltage to the motor remains fixed, how can the motor’s speed be varied? The function of the motor speed controller is to allow this to b ...
MAX8595X/MAX8596X High-Efficiency, 36V Step-Up Converters with T
MAX8595X/MAX8596X High-Efficiency, 36V Step-Up Converters with T

... The high efficiency and small size of the MAX8595X/ MAX8596X make them ideally suited to drive up to nine series-connected LEDs. These devices operate as a boost DC-DC converter that regulates output current rather than voltage. The MAX8595X/MAX8596X provide even illumination by sourcing the same ou ...
INSTRUCTION MANUAL
INSTRUCTION MANUAL

Methodology for Effective Hierarchical Verification of Low
Methodology for Effective Hierarchical Verification of Low

... - To get maximum speed and lower power at the same time, only blocks that need to work at higher clock rates can operate with a higher supply voltage while the other blocks can operate with a lower voltage. ...
MAX1573 White LED 1x/1.5x Charge Pump in UCSP and Thin QFN General Description
MAX1573 White LED 1x/1.5x Charge Pump in UCSP and Thin QFN General Description

... white LEDs with regulated constant current for uniform intensity. By utilizing proprietary adaptive 1x/1.5x modes and ultra-low-dropout current regulators, it maintains the highest possible efficiency over the full 1-cell Li+ battery input voltage range. The 1MHz fixedfrequency switching allows for ...
Slides, chapter 20
Slides, chapter 20

... is violated, then the inductor current never reaches zero. In consequence, the transistor cannot switch off at zero current. ...
12.2 - physics
12.2 - physics

... occurs only for a moment.  What about the average value?  This is zero over a complete cycle and so is not very helpful! ...
RADIATION-HARD OPTO-LINK FOR THE ATLAS PIXEL DETECTOR
RADIATION-HARD OPTO-LINK FOR THE ATLAS PIXEL DETECTOR

... single-ended signal appropriate to drive a VCSEL in a common cathode array. The output current of the VDC is to be variable between 0 and 20 mA through an external control current, with a standing current (dim current) of ~1 mA to improve the switching speed of the VCSEL. The rise and fall times of ...
AD8079
AD8079

... traces, a space (5 mm min) should be left around the signal lines to minimize coupling. Line lengths on the order of less than 5 mm are recommended. If long runs of coaxial cable are being driven, dispersion and loss must be considered. ...
Technical Note SolarEdge Fixed String Voltage, Concept of Operation
Technical Note SolarEdge Fixed String Voltage, Concept of Operation

... Voltage, Concept of Operation The SolarEdge system maintains a fixed string voltage regardless of string characteristics and environmental conditions. This application note details the concept of operation of the SolarEdge fixed string voltage and its benefits. Concept of Operation The SolarEdge pow ...
PDF
PDF

ST13003-K
ST13003-K

POTENTIOMETER INTERNAL EXTERNAL 10V
POTENTIOMETER INTERNAL EXTERNAL 10V

... appear noisy. In general a tracking distance (creepage distance) of 25mm (1 inch), per 10kV to earth is advised as a minimum to ensure no breakdown or corona occurs, a much greater distance will be required under adverse conditions. Care must be taken not to damage the cable inner when forming the c ...
< 1 ... 884 885 886 887 888 889 890 891 892 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report