• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Chapter 11: Data acquisition and manipulation
Chapter 11: Data acquisition and manipulation

Shunt reactive power compensation
Shunt reactive power compensation

- LSBU Research Open
- LSBU Research Open

... Iph = The solar generated current which is affected by solar irradiance and temperature Vpv = The output voltage. Rs = Series resistance. Rp = Parallel resistance. ...
Chapter 11: Data acquisition and manipulation
Chapter 11: Data acquisition and manipulation

... • Analog signals can be converted to digital form using an analog-to-digital converter (ADC). The ADC generally forms just one part of a larger data acquisition system. • Considerable care needs to be taken in applying ADCs and data acquisition systems, using knowledge among other things of timing r ...
ee221_9
ee221_9

... In order to denote the time right before t=0 (limit from the left as t0), and the time right after t=0 (limit from the right as t0), the following notation will be used: ...
Applicability improvement and hysteresis current control method
Applicability improvement and hysteresis current control method

... leads to higher output power. The task of filter (2) which is a high frequency inverter- is harmonic component compensation and it works around 10 kHz. It is obvious that because inverter (2) operates in high frequency, its output power is much less than maximum output power of inverter (1). Recent ...
NTV Series - power, Murata
NTV Series - power, Murata

... The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but th ...
Fingerswitch for Bipolar Forceps
Fingerswitch for Bipolar Forceps

... - Visual Basic versus LabView program - LabView is a program designed specially for real-time data acquisition - Less complicated than Visual Basic - Able to develop stand-alone programs ...
SP 200 - Farnell
SP 200 - Farnell

... Ground for analogue section of A/D converter. It is actively held at 2.8V below V+ and must not be allowed to sink excessive current (>100µA) by, for instance, connecting to a higher voltage. Positive measuring input. IH must be no closer than 1.5V to either the positive or negative supply. Negative ...
HD3413181323
HD3413181323

... voltage in series with the system voltage and a DSTATCOM injects a current into the system to correct the voltage sag, swell and interruption. Comprehensive results are presented to assess the performance of each device as a potential custom power solution. ...
PDF
PDF

... and current is chopped so well suited for various renewable energy sources radio interference is low. such as photovoltaic cell, fuel cell etc. For active Due to high THD, power conversion from AC to DC and then DC to large, costly and THD is low, so simple circuit AC as per requirement, the cascade ...
thpma046
thpma046

... good part-load efficiency. 3. The phase angle between the source voltage and current (φ) depends on Q. They are nearly in-phase only for higher values of Q but φ changes steeply with slight shift in operating frequency. ...
Report 2015
Report 2015

... fundamental frequency, aggregation is made for intervals of 3 seconds, 10 minutes, 2 hours. For parameters OPQP the word “online” means that the relevant parameters are provided for the last three-second aggregation interval; parameter “PF” means total power factor, parameter “cos(φ1)” means displac ...
CM-300/350 (V2) - General Dynamics Mission Systems
CM-300/350 (V2) - General Dynamics Mission Systems

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0

... The 0-10 V Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (0-10 V or 0-20 mA). It accepts power supply voltages from 9 to 28 VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC curre ...
MS Supplies Technical Description Template
MS Supplies Technical Description Template

Document
Document

... information either side of the boundary ...
EVL6699-90WADP
EVL6699-90WADP

... Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the ST products and services described herein. No license, express or implied, by estoppel or other ...
Automatic Power Factor Improvement by using
Automatic Power Factor Improvement by using

... displacement time td between pulse generator (A) and pulse generator (B) increases, then PF becomes low. Phase displacement time (td) is low, PF becomes high. So phase displacement time (td) is inversely proportional to PF. This is shown in Fig.13 graphically. This phase displacement time (td) is in ...
Low Voltage - Portable - Explosion Proof Infrared LED Light
Low Voltage - Portable - Explosion Proof Infrared LED Light

... Durability: This unit incorporates a 21 watt Infrared LED lamp assembly containing seven Edixeon® 2 Watt Infrared LEDs and a copper-free cast aluminum housing with a thermoset powder coat finish. The shell, covers and sealed fittings are also made of copper-free aluminum. The lens is constructed of ...
Bulletin
Bulletin

... The value must be adjusted in the front panel for the best response, without oscillations and minimum overshoot and undershoot. Normally used in almost all applications. • S6- “Integrative Time”: Enables the I portion of the error amplifier. The integrative time must be adjusted in the front panel f ...
Power Amplifier Circuits
Power Amplifier Circuits

active power filters based on a single current measurement system
active power filters based on a single current measurement system

... As it is known, active power filters are used for compensating the reactive power and the low-order current harmonics generated by a non-linear load. The maximum harmonic order that an active filter is able to compensate determines the filter bandwidth. As a result of the active filter operation, th ...
TPS54160 60-V, Step-Down LED Driver Design Guide Application Report ..............................................................
TPS54160 60-V, Step-Down LED Driver Design Guide Application Report ..............................................................

... derived from a higher input voltage. The output voltage is regulated by the internal current mode control circuitry to maintain a constant voltage over varying line and load conditions. The TPS54160 is not limited to use in the standard buck topology. This application report demonstrates the TPS5416 ...
Chapter 11 Amplifiers: Specifications and External Characteristics
Chapter 11 Amplifiers: Specifications and External Characteristics

... 3. Understand the importance of input and output impedances of amplifiers. 4. Determine the best type of ideal amplifier for various applications. 5. Specify the frequency-response requirements for various amplifier applications. ...
< 1 ... 883 884 885 886 887 888 889 890 891 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report