• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Chap12--Digital Data..
Chap12--Digital Data..

Water Flow Meter - Coulton Instrumentation
Water Flow Meter - Coulton Instrumentation

... from the OUTPUT menu. Details of this selection are covered in the Flow Meter Configuration section of this manual. Two pulse output options are available with the FUSION:  Turbine meter simulation—This option is utilized when a receiving instrument is capable of interfacing directly with a turbin ...
MMBZ27VDA-G
MMBZ27VDA-G

... statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or ...
Manual, TAPS Traction Auxiliary Power Supply Motion Control Engineering, Inc.
Manual, TAPS Traction Auxiliary Power Supply Motion Control Engineering, Inc.

radiac set an/pdr-56f (nsn 6665-01-113-9530)
radiac set an/pdr-56f (nsn 6665-01-113-9530)

migmaster 250
migmaster 250

... 1. Welders having pacemakers should consult their physician before welding. EMF may interfere with some pacemakers. 2. Exposure to EMF may have other health effects which are unknown. 3. Welders should use the following procedures to minimize exposure to EMF: A. Route the electrode and work cables t ...
INDUSTRIAL CRANE CONTROLLED BY FLEX SENSOR Year
INDUSTRIAL CRANE CONTROLLED BY FLEX SENSOR Year

... If the RSTDISBL Fuse is programmed, PC6 is used as an I/O pin. Note that the electrical characteristics of PC6 differ from those of the other pins of Port C. If the RSTDISBL Fuse is unprogrammed, PC6 is used as a Reset input. A low level on this pin for longer than the minimum pulse length will gene ...
X-Lock TS520 - Cumbria Designs
X-Lock TS520 - Cumbria Designs

... omitted the 78L08 8V regulator and instead installed a wire link between its input and output pads. The analogue output stages are now supplied directly by the 9V regulated VFO supply. Conclusion In closing, I can wholeheartedly recommend the X-Lock kit from Cumbria Designs. It does exactly what it ...
introduction-to-the
introduction-to-the

... Programmers work in the virtual world. Machinery works in the physical world. How does one connect the virtual world to the physical world? Enter the microcontroller. A microcontroller is basically a small-scale computer with generalized (and programmable) ...
62-0316_A S03, S05 Series Low-Torque Spring
62-0316_A S03, S05 Series Low-Torque Spring

... The actuators are designed to open a damper by driving the damper shaft in either a clockwise or counterclockwise direction (see Fig. 2). ...
64
64

... based upon the difference between the absolute values of hardware like oscillators, amplitude demodulators, and the transducer signals, together with a single CMOS Type consequently weight, size, and cost when compared to the II tracking RDC. This paper gives an overview of the method in [1]. In [1] ...
Atmel AT11480: Analog Comparator Application Examples
Atmel AT11480: Analog Comparator Application Examples

... Before enabling the AC, the input and output events must be configured in the Event Control register (EVCTRL). These settings cannot be changed while the AC is enabled. Each individual comparator must also be configured by its respective Comparator Control register before that comparator is enabled. ...
Dimmers Buying Guide - Leviton Home Solutions
Dimmers Buying Guide - Leviton Home Solutions

An introduction to digital electronics
An introduction to digital electronics

... level by very small amounts, so we can change the output voltage by very small amounts. A digital sensor, on the other hand, is a two-state affair. A switch is either on or off - just two possible states. The output voltage, as a result, has one of only two possible values. These ideas are shown in ...
H P D C
H P D C

25 Watt - EPtronics
25 Watt - EPtronics

... application as to offer products with exceptional performance. For the last few years EPtronics has made significant investment for being able to offer products with advanced technology, high performance, reliability and a variety of selections for fast evolving and growing LED applications. With mu ...
Siemens Sinamics V20 Getting Started
Siemens Sinamics V20 Getting Started

... • Suitable for Type 1 or Type 2 SPD application • Clamping shall be provided between phases and also between phase and ground NOTICE Inverter damage due to improper mains disconnection Improper mains disconnection can cause inverter damage. Do not perform mains diconnection on the motor-side of the ...
Liebert Series 300 DT Dual Input UPS GS
Liebert Series 300 DT Dual Input UPS GS

... 10000VA Rack-Tower, Dual Inverter Uninterruptible Power Supply System ...
metering_270411_psdas
metering_270411_psdas

...  The meter continuously computes the average of the RMS values of the three line-to-neutral VT secondary voltages as a percentage of 63.51 V, and displays the same on demand.  The meter also computes the reactive power (VAR) on 3phase, 4-wire principle, with Class 2 accuracy, and integrates the re ...
Transformer Failure Due to Circuit-Breaker
Transformer Failure Due to Circuit-Breaker

... B. Mitigating the Switching Transient Various surge protection schemes exist to protect the transformer primary winding from vacuum-breaker-switchinginduced transients. A surge arrester provides basic overvoltage protection (magnitude only). The arrester limits the peak voltage of the transient volt ...
74LCX07 Low Voltage Hex Buffer with Open Drain Outputs 74LCX07 — Lo
74LCX07 Low Voltage Hex Buffer with Open Drain Outputs 74LCX07 — Lo

... Figure 5. 14-Terminal Depopulated Quad Very-Thin Flat Pack No Leads (DQFN), JEDEC MO-241, 2.5 x 3.0mm Package drawings are provided as a service to customers considering Fairchild components. Drawings may change in any manner without notice. Please note the revision and/or date on the drawing and co ...
FSA6157 Low-RON SPDT (0.8Ω) Negative
FSA6157 Low-RON SPDT (0.8Ω) Negative

... arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. Buyer is responsible for its products and applications using ON Semiconductor products, including compliance w ...
Motor Drive Board, Ver.5 Assembly Manual Micon Car Kit, Ver.5.1
Motor Drive Board, Ver.5 Assembly Manual Micon Car Kit, Ver.5.1

... kit has four batteries in the control system (MCU board) and four batteries in the drive system (motor drive board ver.5). If you want faster motor rotation speed, make the voltage applied to motor drive board ver.5 7.2 – 9.6 V supplied from six to eight batteries in series. Since the maximum voltag ...
AVR120: Characterization and Calibration of the
AVR120: Characterization and Calibration of the

... An ideal ADC is just a theoretical concept, and cannot be implemented in real life. It has infinite resolution, where every possible input value gives a unique output from the ADC within the specified conversion range. An ideal ADC can be described mathematically by a straight-line transfer function ...
ADS4249 Dual-Channel, 14-Bit, 250-MSPS Ultralow
ADS4249 Dual-Channel, 14-Bit, 250-MSPS Ultralow

... performance and consume extremely low power with a 1.8-V supply. This topology makes the ADS4249 well-suited for multi-carrier, wide-bandwidth communications applications. The ADS4249 has gain options that can be used to improve SFDR performance at lower full-scale input ranges. This device also inc ...
< 1 ... 84 85 86 87 88 89 90 91 92 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report