• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MAX1615/MAX1616 High-Voltage, Low
MAX1615/MAX1616 High-Voltage, Low

... 19-1225; Rev 2; 1/98 ...
ds26ls31cm
ds26ls31cm

... Note 1: ‘‘Absolute Maximum Ratings’’ are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the devices should be operated at these limits. The tables of ‘‘Electrical Characteristics’’ provide conditions for actual device operation. Note 2: Unle ...
Document
Document

... Abstract-A single processor controls a three phase silicon controlled rectifier (SCR) power converter. An inexpensive, dual optoisolator interface to the power line provides noise rejection and an improved measure of the zero crossing. A dynamic digital phaselocked loop (PLL) algorithm implemented i ...
Encoder Signal Broadcaster
Encoder Signal Broadcaster

... Signal processing modules (pulse converter, integer countdown, anti-dither) can be added to each output for additional capabilities Accepts all standard input voltages and types: single ended, differential and open collector Signals are optically isolated for high noise immunity Compact package save ...
Compact Power meter for cost savings through Energy monitoring
Compact Power meter for cost savings through Energy monitoring

... Recording interval can be set between 1 second and 1 hour Tablet device ...
power transformers
power transformers

Aalborg Universitet Phase Standalone DG System
Aalborg Universitet Phase Standalone DG System

EE32828833
EE32828833

STATCOM
STATCOM

... blocked one time per line voltage cycle. In this case, each GTO in a single branch conducts during a half-cycle (180 degrees) of the fundamental period. The combined pulses of each leg are 120 degrees phase-shifted. In this way, the converter produces a balanced set of three voltages, as illustrated ...
Manual - Dortronics
Manual - Dortronics

... voltage devices. This equipment is frequently used for power isolation between devices controlled from a common point. The xRO board can also be used to disconnect power to selected devices when the on-board Auxiliary Relay is configured to override the trigger inputs controlling the four DPDT relay ...
CrGRE Symposium "New and irnproved materials for
CrGRE Symposium "New and irnproved materials for

... these currents are mainly capacitive wattless currents, the power rating of the variac can still be small if reactive power campensation is made by means of a low voltage inductance (choke), as can be seen in the circuit diagram. Such chokes for low voltages are small and inexpensive. If tests shall ...
CPI 2000 - Woody`s CB GAZETTE
CPI 2000 - Woody`s CB GAZETTE

... The voltage controlled oscillator (VCO) is a free-running oscillator whose frequency can be shifted by changing the DC control voltage applied. Increasing control voltage causes higher frequency of operation. The output of the VCO is mixed with a fixed crystal oscillator to produce a lower frequency ...
CS-24 & CHS-24 Indoor Wall Mount Colored Lens Strobe and Horn/Strobe Series Features
CS-24 & CHS-24 Indoor Wall Mount Colored Lens Strobe and Horn/Strobe Series Features

STK554U3xx Series Application Note
STK554U3xx Series Application Note

Basic Principles of ERP Recording
Basic Principles of ERP Recording

BD37544FS
BD37544FS

Linear Voltage regulators
Linear Voltage regulators

electronic devices ii
electronic devices ii

IE (3341105)
IE (3341105)

Powering i.MX35 using TPS650250
Powering i.MX35 using TPS650250

... EMI I/O interface power supply should be set up according to external memory. For example, if using SDRAM then NVCC_EMI1,2,3 should all be set at 3.3 V (typ). If using MDDR or DDRe, NVC_EMI1,2,3 must be set at 1.8 V (typ). MLB interface I/O pads can be programmed to function as GPIO for the consumer ...
Micronote 128
Micronote 128

... are also clipped in this direction as shown, but at a low level on the order of a volt or two. Higher power TVS devices including the 15KPxxx and 30KPxxx series use stacked die and have higher VF values. Unidirectional devices are used across dc power and dc signal lines. In addition to their normal ...
Three-terminal adjustable negative voltage
Three-terminal adjustable negative voltage

... percentage output change) per watt of power change in a specified time. Thermal regulation error is independent of electrical regulation or temperature coefficient, and occurs within 5 ms to 50 ms after a change in power dissipation. Thermal regulation depends on IC layout as well as electrical desi ...
experimental procedure
experimental procedure

... To investigate different oscillator types and to compare with each other. THEORY: Oscillator is a circuit that product a signal whose frequency and amplitude is defined. Oscillators can product signals in different forms. The frequency and amplitude of these signals could have been regulated. Oscill ...
CR-800 Datalogger
CR-800 Datalogger

K346670
K346670

... main constraint. The decision variables chosen to achieve the above objective were the generator bus voltages, reactive power generation by capacitor banks and transformer tap settings, more over this algorithm provides a new dimension in solving such kind of multi variable problem such that the obt ...
< 1 ... 805 806 807 808 809 810 811 812 813 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report