• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Pro200 OM SSN.QXD
Pro200 OM SSN.QXD

... Note — Both Binding Post and Speakon output connectors may be used at the same time. Both sets are are parallel to each other, so if you use them together be sure calculate the total impedance for each channel. ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... inverter and the execution time is greatly reduced. The dc-link neutral-point potential control algorithms are implemented more easily. And the proposed method can be applied to the multi-level inverters above three and five level. Keywords- Multilevel inverter, three level inverter, five level inve ...
LF411 Low Offset Low Drift JFET Input Operational Amplifier
LF411 Low Offset Low Drift JFET Input Operational Amplifier

... Note 2: For operating at elevated temperature, these devices must be derated based on a thermal resistance of ijA. Note 3: These devices are available in both the commercial temperature range 0§ C s TA s 70§ C and the military temperature range b 55§ C s TA s 125§ C. The temperature range is designa ...
An Autonomous Industrial Load Carrying Vehicle
An Autonomous Industrial Load Carrying Vehicle

... which emphasizes the importance of interaction between the robot and operator to facilitate situational awareness. Similar to the PdaDriver system, Keskinpala et al. [18] describe a PDA-based touch-screen interface for mobile robot control through which the user teleoperates a ground robot. In addit ...
Power supply system for AC coaches
Power supply system for AC coaches

... angles, qa and qd, are required to make sure that there is some voltage across the triac before it is triggered. Figure 5 c ) shows the advance and retard angle for phase L1. A further comparator generates a reference waveform, VC5, required for the isolation of two half cycles of cosine waves. Two ...
Low Current/High Resistance Measurements
Low Current/High Resistance Measurements

... resistor is significantly smaller than the resistance of the DUT and the currents to be measured are not very small (not much lower than microamp level [10 –6A]), shunt ammeters work fine. ...
An Oscillating Active CMOS Pixel for Subretinal Stimulation
An Oscillating Active CMOS Pixel for Subretinal Stimulation

... the circuit does indeed oscillate (how exciting) the conductance of T1 controls how fast the output S charges the conductance of T2 controls how fast the output S discharges the higher the conductance on either T1 or T2, the faster the circuit oscillates the ratio of the conductances on T1 and T2 de ...
LT1260 - Low Cost Dual and Triple 130MHz Current Feedback Amplifiers with Shutdown
LT1260 - Low Cost Dual and Triple 130MHz Current Feedback Amplifiers with Shutdown

1. Introduction
1. Introduction

... STMicroelectronics, has a sensitivity of 0.67 mV/⁰/s and a reference voltage of 1.23V. Based on the change in angular velocity (which is measured in ⁰/s), the output signal from the gyroscopes will change by 0.67 mV for every ⁰/s increase in angular velocity. This output signal can then be fed into ...
GIA-05X Manual - NPI Electronic
GIA-05X Manual - NPI Electronic

... appropriate safety measures for handling electronic devices. Before using any device please read manuals and instructions carefully. The device is to be operated only at 115/230 Volt 60/50 Hz AC. Please check for appropriate line voltage before connecting any system to mains. Always use a three-wire ...
JOB SHEET: HF Systems We~k Eight 8-1-3 TITLE: Setting
JOB SHEET: HF Systems We~k Eight 8-1-3 TITLE: Setting

... to ob·tain comrwmicat,ions over a great distance by utilizing the AN;\\TRr.-1 SSE Radio Set from a local position. However, this skill limits the operator to one posj_tion, directly in front of the equipment being utilizedo Since radio is the 11Voice of Commandll and as such must serve in many situa ...
data sheet data sheet - National Model Railroad Association
data sheet data sheet - National Model Railroad Association

... correct to install the ammeter in the protected conductor, between protective device and load. Voltmeters must always be connected in parallel with the circuit to be measured. In Figs. 3 through 9, meters are conventional (zero left) unless marked (*), which indicates a zero-center instrument (note ...
Closed loop control
Closed loop control

... • 3Φ AC supply is fed to the stator and a variable resistance R2 is connected in the rotor side. • By varying the rotor circuit resistance R2 – The starting torque & starting current can be controlled. ...
Cables, conduits and trunking
Cables, conduits and trunking

... Cable Volt Drop All cables have resistance, and when current flows in them this results in a volt drop. Hence, the voltage at the load is lower than the supply voltage by the amount of this volt drop. Volt drop may be calculated using the basic Ohm's law formula V = I x R Unfortunately, this simple ...
Using a VMI Optocoupler in Conjunction with High Voltage Relays
Using a VMI Optocoupler in Conjunction with High Voltage Relays

... and with mechanical switching lifetime in the millions of cycles. Although adequate for switching low voltages, this circuit is unreliable for high voltages because relays are “hot switched” i.e. contacts are opened and closed with voltage across them, and with current flowing through them. This lea ...
ANALOGUE COMPUTERS INTRODUCTION There are 2 main types
ANALOGUE COMPUTERS INTRODUCTION There are 2 main types

... Now proceed to plot curves for various values of a and b. Can you interpret them physically? Experiment 4: Damped Free Oscillations Many systems exhibit one dimensional oscillatory motion, as a result of obeying the second order differential equation: ...
Actuators
Actuators

... • Several types, all of which use electrical energy to turn a shaft - DC motors: shaft turns continuously, uses direct current - AC motors: shaft turns continuously, uses alternating current - stepper motors: shaft turns in discrete increments (steps) • Many many different configurations and “subtyp ...
Millimetre Wave Generator G4-143g
Millimetre Wave Generator G4-143g

... There are two modes of frequency: Internal and External Frequency Control modes. Turn on the Generator as directed in part 8. 9.1.1 Set Internal Frequency control mode. One should check LED “External” on the button “Frequency Control” (11). If LED doesn’t glow, it means that the device is installed ...
Power-Gated MOS Current Mode Logic (PG
Power-Gated MOS Current Mode Logic (PG

AD8002
AD8002

MAX1553 Evaluation Kit - Part Number Search
MAX1553 Evaluation Kit - Part Number Search

... LED intensity can be controlled using the BRT1 input. BRT1 can be used either as an analog or digital input. When using BRT1, remove the shunt from JU1. Connect a 0 to 1.72V voltage source to BRT1, where 0V corresponds to the dimmest setting and 1.72V is full brightness. Ground the voltage source to ...
papers in PDF format
papers in PDF format

... system are to be considered. Feeder impedance also has its role to play in power distribution systems. Based on the location on the feeder where load is connected, we can classify it into two types. When the long feeder has load connected at the end with small short-circuit current value, it is know ...
Low Frequency Sounder/Strobes
Low Frequency Sounder/Strobes

... prevent contamination of the mounting plate. (For indoor models only) 4. To attach product to mounting plate, remove the paint cover, then hook tabs on the product housing into the grooves on mounting plate. 5. Then, swing product into position to engage the pins on the product with the terminals ...
5 V low drop voltage regulator
5 V low drop voltage regulator

Bridge-Type Sensor Measurements are Enhanced
Bridge-Type Sensor Measurements are Enhanced

... This was traditionally done by adding a trim potentiometer in series with the external gain resistor of the instrumentation amplifier. To achieve higher levels of performance over a wider temperature range, system designers turned to software-controlled gain compensation. ...
< 1 ... 599 600 601 602 603 604 605 606 607 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report