• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
2141706 - Gujarat Technological University
2141706 - Gujarat Technological University

... 6. To study and perform summing amplifier and subtractor 7. To study and perform voltage to current converter with grounded load and with floating load 8. To study and perform current to voltage converter 9. To study and perform comparator circuit using op-amp and make PWM wave forms. 10. To study a ...
How to size a genset: Proper generator set sizing requires analysis
How to size a genset: Proper generator set sizing requires analysis

... example, VFD loads on a generator must be less than approximately 50 percent of generator capacity to limit total harmonic distortion to less than 15 percent. ...
Name:
Name:

... power supply voltmeter, power supply ammeter) is most likely to have caused your observed non-zero intercept values? Why do you think that? How much is this meter misadjusted? Be specific. ...
NetForce Whitepaper Series
NetForce Whitepaper Series

... longitudinal balance reading must be done. A longitudinal balance measurement is taken with the C-message filter and readings should be ≥60dBrnC. This measurement must be done at both ends of the span, and the worst reading should be taken as accurate. Since this measurement is taken using the Cmess ...
SLP 05 - Cary Audio
SLP 05 - Cary Audio

... IMPORTANT SAFETY INSTRUCTIONS 15. REPLACEMENT PARTS: When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer or those having the same characteristics as the original parts. Unauthorized substitutions may result in fire, electric s ...
743CB Series FIELD STATION MICRO Controller
743CB Series FIELD STATION MICRO Controller

... Moves through variables being displayed on bargraphs, displaying each, in turn, on lower alphanumeric display. Also provides access to remote set point, ratio, and totalized count, provided these have been configured. Long Depression (≥0.3 s): Toggles between faceplates of the two controllers, indic ...
Design And Verification of A PLL Based Clock And Data Recovery
Design And Verification of A PLL Based Clock And Data Recovery

... loop and the fine loop depending on their functionality. Following power up, only the coarse loop operates and the system functions as a frequency synthesizer to align the divided VCO clock with the reference clock of 78 MHz. After the lock is achieved, coarse loop stops and fine loop aligns the ris ...
- Interroll
- Interroll

... • externally via three digital inputs with eight levels (speed modifications are also possible in running operation, whereby a form of ramp function can be implemented with corresponding switching of a PLC) The speed setting is converted to an analog control voltage by the DriveControl and output ...
Document
Document

... Force-commutated inverter technology started shortly after controlled mercury arc rectifiers came into practice [5], both voltage-fed and current-fed topologies appearing. After thyristors appeared, attention focused initially on the voltage-fed topology, and subsequently current-fed inverters recei ...
TIME-A-VALVE®
TIME-A-VALVE®

... Use whenever you want a device to go on after an adjustable time delay and then stay on as long as power is supplied. • Two cylinders are to be fed forward, one before the other. Send the same signal to one cylinder directly, the other through a Delay-on-Make, Time-A-Valve. One cylinder advances imm ...
MC100LVEL14 - 3.3 V ECL 1:5 Clock Distribution Chip
MC100LVEL14 - 3.3 V ECL 1:5 Clock Distribution Chip

... The MC100LVEL14 is a low skew 1:5 clock distribution chip designed explicitly for low skew clock distribution applications. The device can be driven by either a differential or single-ended ECL or, if positive power supplies are used, PECL input signal. The LVEL14 is functionally and pin compatible ...
Data - KB Electronics
Data - KB Electronics

... operation and the hazards involved. Proper installation, which includes electrical connections, fusing or other current protection, and grounding, can reduce the chance of electrical shocks, and/or fires, in this product or products used with this product, such as electric motors, switches, coils, s ...
Application Note AN4107 Design of Power Factor Correction Using FAN7527  1. Introduction
Application Note AN4107 Design of Power Factor Correction Using FAN7527 1. Introduction

... external gate pull-down resistor. Internal voltage clamping ensures that the output driver is always lower than 14V when supply voltage exceeds the rated Vgs of the external MOSFET. This eliminates an external zener diode and extra power dissipation associated with it that otherwise is required for ...
BD8271EFV
BD8271EFV

PDF
PDF

... each pair of parallel driven T-PMs. In addition, the bus bars of the main circuit are arranged and connected to ensure wide parallel plates and thus reduce inductance. With these measures, as shown in Fig. 2 b), the parallel drive current is equally distributed through the two T-PMs. 2.2 Vibration-r ...
Catheter Guidewire Control System
Catheter Guidewire Control System

... • (2) Jameco 8.4 V motors ordered – Suggested in Motor Controller Board documentation • Tested with Motor Controller board – Full functionality achieved – Total current draw = roughly 1 amp while running. ...
é MENTOR New Concept Modular Indicator Lamp EN PDF, 349.8 KB
é MENTOR New Concept Modular Indicator Lamp EN PDF, 349.8 KB

...  Suitable for use with a great many applications  Freely-selectable LEDs: single-colour, two-colour, RGB, warm white or cool white, special colours, or night vision  Diverse options as regards the beam appearance, voltage and housing  Optional: Connector with plug  UV-resistant: Suitable for ou ...
vc 400-045 vectron elektronik manual
vc 400-045 vectron elektronik manual

Full-text
Full-text

... The fuel cells used in domestic application, either as main power supply or backup source, need to be connected to the grid. Thereby, their low DC voltage has to be converted by means of a power converter into AC voltage in accordance with the grid voltage parameters. Such power converter systems us ...
Roll-ur-Own Crowbar OV Module.
Roll-ur-Own Crowbar OV Module.

... dump” speaks to a characteristic native to the physics of alternator performance. Its existence has been known since the beginnings of alternator use in vehicles . . . but it was only a concern after a proliferation of solid state electronics for fuel injection systems, ignition systems, anti-lock b ...
ABB Oy AC Drive efficiency and loss estimation Example, quadratic
ABB Oy AC Drive efficiency and loss estimation Example, quadratic

... automatically – in this case multiply the typical losses with 1.16. We get 1,16 x 4000W = 4640 W motor losses. On partial loads the minimum safety margin is 20%. When compared to the original power requirement we have calculated worst case motor efficiency ...
1.  Checking the Contents of the Package
1. Checking the Contents of the Package

... • Although they are well-insulated, do not touch the instrument or any cables connected to the instrument when voltage is being applied to them. • When wiring to the sensor unit's primary current input terminal, tighten the terminal screw to 20–30 N/m torque. If the tightening torque is too high, da ...
Modifying a Fender Blues Jr. Guitar Amplifier
Modifying a Fender Blues Jr. Guitar Amplifier

IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)
IOSR Journal of VLSI and Signal Processing (IOSR-JVSP)

... 3.2 Using GA in Σ∆ ADC Design In the design of Σ∆ ADCs, we need to optimize a large set of parameters including the overall structures and the performance of the building blocks to achieve the required signal-to-noise ratio. Therefore, behavioral simulations were carried out using a set of Simulink ...
Paralleling Dissimilar Generators
Paralleling Dissimilar Generators

< 1 ... 476 477 478 479 480 481 482 483 484 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report