MAX1407/MAX1408/MAX1409/MAX1414 Low-Power, 16-Bit Multichannel DAS with Internal Reference,10-Bit DACs, and RTC General Description
... inputs, while the MAX1407/MAX1414 include four auxiliary analog inputs and two 10-bit force/sense DACs. The MAX1414 features a 50mV trip threshold for the signal-detect comparator while the others have a 0mV trip threshold. The MAX1409 is a 20-pin version of the DAS family with a differential 4:1 in ...
... inputs, while the MAX1407/MAX1414 include four auxiliary analog inputs and two 10-bit force/sense DACs. The MAX1414 features a 50mV trip threshold for the signal-detect comparator while the others have a 0mV trip threshold. The MAX1409 is a 20-pin version of the DAS family with a differential 4:1 in ...
Nicolas DEGRENNE Gestion de l`énergie des piles à combustible
... generate electrical energy. They are interesting because they accept a wide range of organic matter as a fuel. Potential applications include autonomous wastewater treatment, bio-batteries, and ambient energy scavenging. MFCs are low-voltage, low-power devices that are influenced by the rate at whic ...
... generate electrical energy. They are interesting because they accept a wide range of organic matter as a fuel. Potential applications include autonomous wastewater treatment, bio-batteries, and ambient energy scavenging. MFCs are low-voltage, low-power devices that are influenced by the rate at whic ...
Phase Distance & Power Transformers
... • Fault current generally contains dc offset in addition to ac power frequency component • Ratio of dc to ac component of current depends on instant in the cycle at which fault occurred • Rate of decay of dc offset depends on system X/R ...
... • Fault current generally contains dc offset in addition to ac power frequency component • Ratio of dc to ac component of current depends on instant in the cycle at which fault occurred • Rate of decay of dc offset depends on system X/R ...
RF5616 - Qorvo
... stability. May need external circuitry to bring output voltage to desired level. RF output pin. This pin is matched to 50 internally. This pin has a DC blocking cap from the collector side of the final stage but it is an RF short at the RF OUT Pins 10 and 12 therefore an external DC blocking capaci ...
... stability. May need external circuitry to bring output voltage to desired level. RF output pin. This pin is matched to 50 internally. This pin has a DC blocking cap from the collector side of the final stage but it is an RF short at the RF OUT Pins 10 and 12 therefore an external DC blocking capaci ...
5400 TECSource User's Manual
... Thank you for choosing the 5400 Series TECSource from Arroyo Instruments. Your TECSource is a combination of leading edge technology combined with years of experience in the field of temperature control. With a crystal clear 4-line VFD display, very high power output, multi-sensor support, both RS23 ...
... Thank you for choosing the 5400 Series TECSource from Arroyo Instruments. Your TECSource is a combination of leading edge technology combined with years of experience in the field of temperature control. With a crystal clear 4-line VFD display, very high power output, multi-sensor support, both RS23 ...
Basics of AC Motors
... applications. In addition, you will be better able to describe products to customers and determine important differences between products. You should complete Basics of Electricity before attempting Basics of AC Motors. An understanding of many of the concepts covered in Basics of Electricity is req ...
... applications. In addition, you will be better able to describe products to customers and determine important differences between products. You should complete Basics of Electricity before attempting Basics of AC Motors. An understanding of many of the concepts covered in Basics of Electricity is req ...
grid code requirements for wind turbines turbines connected
... SO and these alterations shall be implemented by the WEF within one minute of receipt of the appropriate signal or instruction from the SO (operational limits and feedback response to the signal will be provided). (9) Alterations to the WEF Active Power output, triggered by frequency changes outside ...
... SO and these alterations shall be implemented by the WEF within one minute of receipt of the appropriate signal or instruction from the SO (operational limits and feedback response to the signal will be provided). (9) Alterations to the WEF Active Power output, triggered by frequency changes outside ...
Fig. 2.12: Simplified equivalent circuit of a transformer at full
... The flux created by the primary can be broken up into two parts: 1- a mutual flux m1, which links the turns of both coils; and 2- a leakage flux f1, which links only the turns of the primary. If the coils are far apart, the mutual flux is very small compared to the total flux ; we then say that ...
... The flux created by the primary can be broken up into two parts: 1- a mutual flux m1, which links the turns of both coils; and 2- a leakage flux f1, which links only the turns of the primary. If the coils are far apart, the mutual flux is very small compared to the total flux ; we then say that ...
NAVSEA TE000-AB-GTP-010 Rev 1 With Change A Parts Derating
... resistor selection; although this standard addresses only selected standard resistors, it should be used to the greatest extent possible. It presents detailed data for use in the design of military equipment. Data is presented on terminology, resistor selection, environmental effects on characterist ...
... resistor selection; although this standard addresses only selected standard resistors, it should be used to the greatest extent possible. It presents detailed data for use in the design of military equipment. Data is presented on terminology, resistor selection, environmental effects on characterist ...
Marif Mahmood
... extender of length 9cm was connected to the webcam. The images sent by the camera were a live feedback. Based on this feedback the user at the computer end decides to steer the vehicle in the appropriate direction. The central processing unit of the computer (CPU) was connected to the vehicle by mea ...
... extender of length 9cm was connected to the webcam. The images sent by the camera were a live feedback. Based on this feedback the user at the computer end decides to steer the vehicle in the appropriate direction. The central processing unit of the computer (CPU) was connected to the vehicle by mea ...
TPS65982 USB Type-C and USB PD Controller, Power Switch and
... power. An additional bidirectional switch path provides USB PD power up to 3 A at a maximum of 20 V as either a source (host), sink (device), or source-sink. The TPS65982 is also an upstream-facing port (UFP), downstream-facing port (DFP), or dual-role port for data. The port data multiplexer passes ...
... power. An additional bidirectional switch path provides USB PD power up to 3 A at a maximum of 20 V as either a source (host), sink (device), or source-sink. The TPS65982 is also an upstream-facing port (UFP), downstream-facing port (DFP), or dual-role port for data. The port data multiplexer passes ...
Direct Torque Control of 5-Phase 10/8 Switched
... advantages over other types of AC machines due to its simple and solid construction. The rotor has a simple laminated structure with neither permanent magnets nor rotor windings, and rotates by using the reluctance torque produced from magnetic saliency between stator poles and rotor poles. Thus, SR ...
... advantages over other types of AC machines due to its simple and solid construction. The rotor has a simple laminated structure with neither permanent magnets nor rotor windings, and rotates by using the reluctance torque produced from magnetic saliency between stator poles and rotor poles. Thus, SR ...
Dynamic Gate
... consumes only dynamic power – no short circuit power consumption since the pull-up path is not on when evaluating lower CL- both Cint (since there are fewer transistors connected to the drain output) and Cext (since there the output load is one per connected gate, not two) by construction can have a ...
... consumes only dynamic power – no short circuit power consumption since the pull-up path is not on when evaluating lower CL- both Cint (since there are fewer transistors connected to the drain output) and Cext (since there the output load is one per connected gate, not two) by construction can have a ...
Arbitrary Function Generator - Engineering Electronics Shop
... HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, a cable of 0.75mm 2 should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used. Any exposed wiring from a cable, ...
... HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, a cable of 0.75mm 2 should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used. Any exposed wiring from a cable, ...
Profil 930-940 and TGV Analogue clocks instructions
... The clock movement is catching the time signal from the DCF77 emitter based in Mainflingen Germany (Frankfurt). This emitter transmits long wave signals at 77,5 kHz and is tuned for Western Europe time. The local reception conditions are very important. After the clock setting to time by radio achie ...
... The clock movement is catching the time signal from the DCF77 emitter based in Mainflingen Germany (Frankfurt). This emitter transmits long wave signals at 77,5 kHz and is tuned for Western Europe time. The local reception conditions are very important. After the clock setting to time by radio achie ...
Rev. 3 – 9th January 2017
... The following warnings, cautions and notes are provided for your safety and as a means of preventing damage to the product or components at the connected machines. This section lists warnings, cautions and notes, which apply generally when handling the Nicotra Gebhardt Driver, classified as General, ...
... The following warnings, cautions and notes are provided for your safety and as a means of preventing damage to the product or components at the connected machines. This section lists warnings, cautions and notes, which apply generally when handling the Nicotra Gebhardt Driver, classified as General, ...
S260-60-3
... In the event that the ac power has not returned within the times listed above, the control will disconnect the battery from the circuit. NNote: The control continuously monitors the battery voltage. To prevent battery damage, the control shuts down automatically upon detection of low battery voltage ...
... In the event that the ac power has not returned within the times listed above, the control will disconnect the battery from the circuit. NNote: The control continuously monitors the battery voltage. To prevent battery damage, the control shuts down automatically upon detection of low battery voltage ...
Over Voltage Protection
... But very few of us deal with over voltage protection. Why well simplistically currents are a function of load and impedance of the system and that can be pretty much anything But even though there appears to a lot of voltages in reality there are only about 20 to 30 which means once you have provide ...
... But very few of us deal with over voltage protection. Why well simplistically currents are a function of load and impedance of the system and that can be pretty much anything But even though there appears to a lot of voltages in reality there are only about 20 to 30 which means once you have provide ...
PECL Clocks and Termination
... broad classes – DC coupled and AC coupled. Within these two classes, there are other possibilities, depending on the particular circuit requirements. When selecting an oscillator, the voltage would be selected to match the circuit being driven. In that case, there are no DC offsets to overcome so th ...
... broad classes – DC coupled and AC coupled. Within these two classes, there are other possibilities, depending on the particular circuit requirements. When selecting an oscillator, the voltage would be selected to match the circuit being driven. In that case, there are no DC offsets to overcome so th ...
ZXMN6A07F Product Summary Features
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Emission Limits for Customer Facilities Connected - Hydro
... disturbances caused by equipment in customer facilities connected to, or to be connected to, the Hydro-Québec transmission system. These limits apply to harmonic emissions, load or current imbalances, rapid voltage changes and flicker at the interface between a customer facility and the transmission ...
... disturbances caused by equipment in customer facilities connected to, or to be connected to, the Hydro-Québec transmission system. These limits apply to harmonic emissions, load or current imbalances, rapid voltage changes and flicker at the interface between a customer facility and the transmission ...
WP12PTOS WP25PTOS Tractor Drive PTO Generators SAFETY FIRST
... electrical power sources for areas where commercial power is not readily available, such as out buildings. This generator includes a color coded voltmeter to warn against high or low voltage, three output power receptacles, an overload protection circuit, and an electronic excitation circuit. To red ...
... electrical power sources for areas where commercial power is not readily available, such as out buildings. This generator includes a color coded voltmeter to warn against high or low voltage, three output power receptacles, an overload protection circuit, and an electronic excitation circuit. To red ...
Pulse-width modulation
Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.