
Pad-Mounted Single-Phase 32-Step Voltage Regulator with
... number bar-coded with "3 of 9" coding with a 0.25" minimum height. 4.4. The regulator shall be of a sealed-tank construction to permit operation at 65°C rise without increasing the oxidation rate of the oil. A pressure-relief device shall be supplied which vents at approximately 5 psig. 4.5. The ext ...
... number bar-coded with "3 of 9" coding with a 0.25" minimum height. 4.4. The regulator shall be of a sealed-tank construction to permit operation at 65°C rise without increasing the oxidation rate of the oil. A pressure-relief device shall be supplied which vents at approximately 5 psig. 4.5. The ext ...
MAX15090/MAX15090A Evaluate: MAX15090/MAX15090A Evaluation Kits General Description
... For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated’s website at www.maximintegrated.com. Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. ...
... For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated’s website at www.maximintegrated.com. Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. ...
G225-60-1
... number bar-coded with "3 of 9" coding with a 0.25" minimum height. 4.4. The regulator shall be of a sealed-tank construction to permit operation at 65°C rise without increasing the oxidation rate of the oil. A pressure-relief device shall be supplied which vents at approximately 5 psig. 4.5. The ext ...
... number bar-coded with "3 of 9" coding with a 0.25" minimum height. 4.4. The regulator shall be of a sealed-tank construction to permit operation at 65°C rise without increasing the oxidation rate of the oil. A pressure-relief device shall be supplied which vents at approximately 5 psig. 4.5. The ext ...
Distribution Systems, Substations, and Integration of Distributed
... Distribution systems serve as the link from the distribution substation to the customer. This system provides the safe and reliable transfer of electric energy to various customers throughout the service territory. Typical distribution systems begin as the medium-voltage three-phase circuit, typical ...
... Distribution systems serve as the link from the distribution substation to the customer. This system provides the safe and reliable transfer of electric energy to various customers throughout the service territory. Typical distribution systems begin as the medium-voltage three-phase circuit, typical ...
US_Renersolar2200~5000_English_User`s
... Instruction 1 Foreword Thank you for buying this inverter. Many years of experience in the design of power device have gone into construction of this device. We hope that this device will also give your solar system many years of trouble-free operation. However, it should be mentioned that an invert ...
... Instruction 1 Foreword Thank you for buying this inverter. Many years of experience in the design of power device have gone into construction of this device. We hope that this device will also give your solar system many years of trouble-free operation. However, it should be mentioned that an invert ...
LaPi Development Kit Datasheet
... Steps 6 through 9 explain how to use the SW Design, Development and Debugging tools to control the basic operation of the ML610Q112. The debugger can be used with the PC based GUI application or any other application code running on either of the Mini LP Micros on the board. 6. To control and modify ...
... Steps 6 through 9 explain how to use the SW Design, Development and Debugging tools to control the basic operation of the ML610Q112. The debugger can be used with the PC based GUI application or any other application code running on either of the Mini LP Micros on the board. 6. To control and modify ...
Test Point Diagram
... Brief check of POWER MODULE W Usually, they are in a state of being short-circuited if they are broken. Measure the resistance in the following points (connectors, etc.). ...
... Brief check of POWER MODULE W Usually, they are in a state of being short-circuited if they are broken. Measure the resistance in the following points (connectors, etc.). ...
MAX5150/MAX5151 Low-Power, Dual, 13-Bit Voltage-Output DACs with Serial Interface _______________General Description
... The reference inputs accept both AC and DC values with a voltage range extending from 0V to (VDD - 1.4V). Determine the output voltage using the following equation (OS_ = AGND): ...
... The reference inputs accept both AC and DC values with a voltage range extending from 0V to (VDD - 1.4V). Determine the output voltage using the following equation (OS_ = AGND): ...
TPS70102 数据资料 dataSheet 下载
... 3.3V/1.5V, 3.3V/1.2V, and adjustable/adjustable voltage options. Regulator 1 can support up to 500mA, and regulator 2 can support up to 250mA. Separate voltage inputs allow the designer to configure the source power. ...
... 3.3V/1.5V, 3.3V/1.2V, and adjustable/adjustable voltage options. Regulator 1 can support up to 500mA, and regulator 2 can support up to 250mA. Separate voltage inputs allow the designer to configure the source power. ...
FAN7080_GF085 - Half Bridge Gate Driver
... the high side driver under high-dV/dt noise circumstances. An advanced level-shift circuit allows high-side gate driver operation up to VS=-5 V (typical) at VBS=15 V. Logic input is compatible with standard CMOS outputs. The UVLO circuits for both channels prevent from malfunction when VCC and VBS a ...
... the high side driver under high-dV/dt noise circumstances. An advanced level-shift circuit allows high-side gate driver operation up to VS=-5 V (typical) at VBS=15 V. Logic input is compatible with standard CMOS outputs. The UVLO circuits for both channels prevent from malfunction when VCC and VBS a ...
LMG5200 80V, 10A GaN Half-Bridge Power Stage
... × 2 mm lead-free package and can be easily mounted on PCBs. The TTL logic compatible inputs can withstand input voltages up to 12 V regardless of the VCC voltage. The proprietary bootstrap voltage clamping technique ensures the gate voltages of the enhancement mode GaN FETs are within a safe operati ...
... × 2 mm lead-free package and can be easily mounted on PCBs. The TTL logic compatible inputs can withstand input voltages up to 12 V regardless of the VCC voltage. The proprietary bootstrap voltage clamping technique ensures the gate voltages of the enhancement mode GaN FETs are within a safe operati ...
Betapack 3 Specification Document
... 2. The triac shall be in an industry standard format that is easily field replaceable without removing any other electrical or electronic devices. J. DIMMERS, FILTERING 1. Each dimmer module shall have an integral inductive filter to reduce the rate of current rise time resulting from the triac swit ...
... 2. The triac shall be in an industry standard format that is easily field replaceable without removing any other electrical or electronic devices. J. DIMMERS, FILTERING 1. Each dimmer module shall have an integral inductive filter to reduce the rate of current rise time resulting from the triac swit ...
AN-5015 USB1T11A Transceiver and Specification Compliance AN- 5015 US
... widely accepted as the preferred mechanism for low to medium speed serial data interfaces. Older connections like RS232 and parallel printer LPTx ports can only be connected to one device at a time. USB allows multiple devices to be attached to a single port enabling greater system flexibility. The ...
... widely accepted as the preferred mechanism for low to medium speed serial data interfaces. Older connections like RS232 and parallel printer LPTx ports can only be connected to one device at a time. USB allows multiple devices to be attached to a single port enabling greater system flexibility. The ...
Product information - VEGABAR 86 VEGABAR 87 VEGAWELL 52
... Keep in mind the following additional factors that influence the operating voltage: ...
... Keep in mind the following additional factors that influence the operating voltage: ...
PCA9551 1. General description 8-bit I
... The I2C-bus is for 2-way, 2-line communication between different ICs or modules. The two lines are a serial data line (SDA) and a serial clock line (SCL). Both lines must be connected to a positive supply via a pull-up resistor when connected to the output stages of a device. Data transfer may be in ...
... The I2C-bus is for 2-way, 2-line communication between different ICs or modules. The two lines are a serial data line (SDA) and a serial clock line (SCL). Both lines must be connected to a positive supply via a pull-up resistor when connected to the output stages of a device. Data transfer may be in ...
FD23917923
... technology has introduced a severe impact to the transmission system utilization with regards to those three constraints. From the steady state power flow viewpoint, networks do not normally share power in proportion to their ratings, where in most situations, voltage profile cannot be smooth. There ...
... technology has introduced a severe impact to the transmission system utilization with regards to those three constraints. From the steady state power flow viewpoint, networks do not normally share power in proportion to their ratings, where in most situations, voltage profile cannot be smooth. There ...
Switch Mode Battery Chargers for Utilities
... Output voltage regulation and output current limit are achieved by adjusting the high frequency PWM. The time constant is relatively fast, in the milliseconds range (e.g. 10ms). Operating at high frequencies, magnetics and filter capacitors are relatively small. Power density can be very high (e.g. ...
... Output voltage regulation and output current limit are achieved by adjusting the high frequency PWM. The time constant is relatively fast, in the milliseconds range (e.g. 10ms). Operating at high frequencies, magnetics and filter capacitors are relatively small. Power density can be very high (e.g. ...
Electronic and Electrical Servicing
... The electrical units of volts, amps and ohms are related, and the relationship is commonly known (not quite correctly) as Ohm’s law, which as an equation is written as V R I. In words, it means that the voltage measured across a given resistor (in volts) is equal to the value of the resistance ( ...
... The electrical units of volts, amps and ohms are related, and the relationship is commonly known (not quite correctly) as Ohm’s law, which as an equation is written as V R I. In words, it means that the voltage measured across a given resistor (in volts) is equal to the value of the resistance ( ...
Pulse-width modulation
Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.