MMBT2222ALP4 Features Mechanical Data
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
... Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use o ...
Modeling of Multi-Pulse VSC Based SSSC and STATCOM
... [13]. The frequency and phase of the three phase voltages generated by the 6-pulse VSC configuration are determined by the gate pulse pattern (GPP) of the commutating devices shown in Figure 2 [14]. The amplitude of the three phase ac voltages is determined by the magnitude of the dc voltage, vdc. T ...
... [13]. The frequency and phase of the three phase voltages generated by the 6-pulse VSC configuration are determined by the gate pulse pattern (GPP) of the commutating devices shown in Figure 2 [14]. The amplitude of the three phase ac voltages is determined by the magnitude of the dc voltage, vdc. T ...
Flicker Noise
... The total RMS noise power from dc to infinity of a signal at the output any practical low pass filter is finite. An equivalent ideal brickwall filter can be found that has the same Vn2(RMS) as a practical low pass filter (the peak gain of the ideal and real filter are the same). The bandwidth ...
... The total RMS noise power from dc to infinity of a signal at the output any practical low pass filter is finite. An equivalent ideal brickwall filter can be found that has the same Vn2(RMS) as a practical low pass filter (the peak gain of the ideal and real filter are the same). The bandwidth ...
General Description Features
... The EV kit circuit provides two 3.5mm headset jacks (J2 and J3) for quick evaluation of the devices. The EV kit also provides a 3.5mm audio jack (J1) for routing audio signals to J2 and J3. The audio signals can also be applied at the AUDIO_L and AUDIO_R PCB pads. The MAX14579E and MAX14579AE have 3 ...
... The EV kit circuit provides two 3.5mm headset jacks (J2 and J3) for quick evaluation of the devices. The EV kit also provides a 3.5mm audio jack (J1) for routing audio signals to J2 and J3. The audio signals can also be applied at the AUDIO_L and AUDIO_R PCB pads. The MAX14579E and MAX14579AE have 3 ...
LC717A00ARGEVK Capacitance‐Digital‐Converter IC for Electrostatic Capacitive Touch Sensors Evaluation
... copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation o ...
... copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation o ...
FJP5555 NPN Silicon Transistor FJP5555 — NPN Silicon T
... cause the failure of the life support device or system, or to affect its life, and (c) whose failure to perform when properly used in safety or effectiveness. accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. ANTI ...
... cause the failure of the life support device or system, or to affect its life, and (c) whose failure to perform when properly used in safety or effectiveness. accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. ANTI ...
EPR Primer from Bruker
... the detector operates at that level, there is a reference arm (point F in the Figure 2-15) which supplies the detector with some extra microwave power or “bias”. Some of the source power is tapped off into the reference arm, where a second attenuator controls the power level (and consequently the di ...
... the detector operates at that level, there is a reference arm (point F in the Figure 2-15) which supplies the detector with some extra microwave power or “bias”. Some of the source power is tapped off into the reference arm, where a second attenuator controls the power level (and consequently the di ...
The Bidirectional Control Thyristor (BCT)
... transformer tap changers in power quality applications. In such high voltage applications several thyristor levels are often required in the valve, each level comprising two thyristors. Conventionally, each thyristor needs its own mounting clamps and connections to the cooling circuit. In some appli ...
... transformer tap changers in power quality applications. In such high voltage applications several thyristor levels are often required in the valve, each level comprising two thyristors. Conventionally, each thyristor needs its own mounting clamps and connections to the cooling circuit. In some appli ...
lt1763.pdf
... 30µA quiescent current makes them an ideal choice. Quiescent current is well controlled; it does not rise in dropout as it does with many other regulators. A key feature of the LT1763 regulators is low output noise. With the addition of an external 0.01µF bypass capacitor, output noise drops to 20µV ...
... 30µA quiescent current makes them an ideal choice. Quiescent current is well controlled; it does not rise in dropout as it does with many other regulators. A key feature of the LT1763 regulators is low output noise. With the addition of an external 0.01µF bypass capacitor, output noise drops to 20µV ...
Temposonics® II
... and Digital Interface Boxes (DIB) are required to interface with transducers over 180 inches in length. Contact an MTS Applications Engineer for details before ordering. Parameter Parameter Input Voltage: ...
... and Digital Interface Boxes (DIB) are required to interface with transducers over 180 inches in length. Contact an MTS Applications Engineer for details before ordering. Parameter Parameter Input Voltage: ...
SFH6318, SFH6319 High Speed Optocoupler, 100 kBd, Low Input
... • Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute maximum ratings for extended p ...
... • Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute maximum ratings for extended p ...
07 reactive energy compensation
... Indeed, let us assume that a cable (or a transformer) carries an active power P , where: P = 3 U n I cos ϕ If we compensate so that cos ϕ ′ is obtained, at constant apparent current (constant I), we will be able to carry an active power of: P ′ = 3 U n I cos ϕ ′ ...
... Indeed, let us assume that a cable (or a transformer) carries an active power P , where: P = 3 U n I cos ϕ If we compensate so that cos ϕ ′ is obtained, at constant apparent current (constant I), we will be able to carry an active power of: P ′ = 3 U n I cos ϕ ′ ...
Dynalo - Detailed Construction (dgardner 5-7
... 1001F into reference locations R7, R17, R21, R37, R47, R51. Install 8 metal film resistors with value 4.99KΩ and tolerance of 1% with the marking 4991F into reference locations R1, R2, R8, R9, R31, R32, R38, R39. Be careful not to accidentally use the 499Ω resistors with marking 4990F. Install 8 met ...
... 1001F into reference locations R7, R17, R21, R37, R47, R51. Install 8 metal film resistors with value 4.99KΩ and tolerance of 1% with the marking 4991F into reference locations R1, R2, R8, R9, R31, R32, R38, R39. Be careful not to accidentally use the 499Ω resistors with marking 4990F. Install 8 met ...
Solid-state Timer - OMRON Industrial Automation
... Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: Ag-alloy H3CR-A8E 5A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = 1) Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: AgSnIn • Transistor output: Open col ...
... Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: Ag-alloy H3CR-A8E 5A at 250 VAC/30 VDC, 0.15A at 125 VDC, resistive load (cosφ = 1) Minimum applied load: 10mA at 5 VDC (failure level: P reference value) Contact materials: AgSnIn • Transistor output: Open col ...
UNIVERSITY OF CALICUT (Abstract)
... journals in electronics, for eg: Electronics for you etc Course Outline Module 1 DC and AC – Types of AC – sinusoidal voltage source – important Terms of AC, definitions – Rectifiers – Half wave, Full wave, bridge – average value, RMS value, PIV, ripple factor, efficiency – comparison of Rectifiers ...
... journals in electronics, for eg: Electronics for you etc Course Outline Module 1 DC and AC – Types of AC – sinusoidal voltage source – important Terms of AC, definitions – Rectifiers – Half wave, Full wave, bridge – average value, RMS value, PIV, ripple factor, efficiency – comparison of Rectifiers ...
CMOS, Rail-to-Rail, I/O OPERATIONAL AMPLIFIERS OPA703 OPA704
... Lead Temperature (soldering, 10s) ............................................... +300°C ...
... Lead Temperature (soldering, 10s) ............................................... +300°C ...
AN124 - 775 Nanovolt Noise Measurement for A Low Noise Voltage
... leakage is determined by following the 5-step procedure given in the figure. Yield to required 5-nanoampere leakage exceeds 90%.1 ...
... leakage is determined by following the 5-step procedure given in the figure. Yield to required 5-nanoampere leakage exceeds 90%.1 ...
Transmission Lines
... Because ω = βc, the guide wavelength will be λ = 2π/β = c/f = c0 /f n = λ0 /n, where λ0 is the free-space wavelength. For a finite length l of the transmission line, the quantity l/λ = nl/λ0 is referred to as the electrical length of the line and plays the same role as the optical length in thin-film ...
... Because ω = βc, the guide wavelength will be λ = 2π/β = c/f = c0 /f n = λ0 /n, where λ0 is the free-space wavelength. For a finite length l of the transmission line, the quantity l/λ = nl/λ0 is referred to as the electrical length of the line and plays the same role as the optical length in thin-film ...
Pulse-width modulation
Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.