• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
AN10777 LPC32x0 power supply design examples Rev. 01 — 22 January 2009
AN10777 LPC32x0 power supply design examples Rev. 01 — 22 January 2009

... The HIGHCORE output pin may be used as a low cost method to save additional power during STOP Mode or low frequency operation by signaling external circuitry to lower the core supply voltage. If any on-chip clocks are running above 14 MHz, nominal core supply voltage must be supplied. If all on-chip ...
DIGITAL MULTIMETER
DIGITAL MULTIMETER

D5V0F4U5P5 Features Mechanical Data
D5V0F4U5P5 Features Mechanical Data

... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Features
Features

... detailed information on CoolRunner-II I/Os. In addition to voltage levels, each input can selectively arrive through Schmitt-trigger inputs. This adds a small time delay, but substantially reduces noise on that input pin. Approximately 500 mV of hysteresis will be added when Schmitt-trigger inputs a ...
Eine 100 Watt Endstufe
Eine 100 Watt Endstufe

section 16
section 16

... silver-plated copper at the connection points and of one-piece construction. ...
ABCs of ADCs - Analog-to-Digital Converter Basics
ABCs of ADCs - Analog-to-Digital Converter Basics

... If we add 1/2 LSB offset to the ADC input, the output code will change 1/2 LSB before it otherwise would. The output changes from 000 to 001 with an input value of 1/2 LSB rather than 1 LSB and all subsequent codes change at a point 1/2 LSB below where they would have changed without the added offse ...
MBI5037
MBI5037

... MBI5037 is an enhanced 16-channel constant current LED sink driver with advanced error detection functions and smart power-saving modes. MBI5037 succeeds MBI5026 and also exploits PrecisionDrive™ technology to enhance its output characteristics. Furthermore, MBI5037 uses the concept of Share-I-O™ te ...
Fisher LCP100 Local Control Panel
Fisher LCP100 Local Control Panel

... This instruction manual includes installation and maintenance information for the Fisher LCP100 local control panel (figure 1). This device is used with Fisher FIELDVUE™ instruments in Safety Instrumented Systems (SIS). Refer to the DVC6200 SIS Digital Valve Controllers for Safety Instrumented Syste ...
An inductorless wideband LNA with a new noise cancelling technique
An inductorless wideband LNA with a new noise cancelling technique

... Consequently, the M1’s noise is cancelled at the output. Considering the LNA shown in Figure 1(b), the noise cancelling condition is found to ...
AD9225 - Analog Devices
AD9225 - Analog Devices

... A single clock input is used to control all internal conversion cycles. The digital output data is presented in straight binary output format. An out-of-range signal indicates an overflow condition that can be used with the most significant bit to determine low or high overflow. PRODUCT HIGHLIGHTS ...
HEHR POWER SYSTEMS
HEHR POWER SYSTEMS

AXICOM Latching Relays
AXICOM Latching Relays

... Relay drivers can be used in those circuits instead of a switch. The circuit performance will be the same (Figure 5). ...
energy consumption in wireless sensor - D
energy consumption in wireless sensor - D

... A critical constraint on sensors networks is that sensor nodes employ batteries. A second constraint is that sensors will be deployed unattended and in large numbers, so that it will be difficult to change or recharge batteries in the sensors. Therefore, all systems, processes and communication prot ...
The superhet or superheterodyne radio receiver
The superhet or superheterodyne radio receiver

... Choosing the right bandwidth It is important to choose the correct bandwidth for a give type of signal. It is obviously necessary to ensure that it is not too wide, otherwise unwanted off-channel signals will be able to pass though the filter. Conversely if the filter is too narrow then some of the ...
15 Watt DC-DC Converters IMX 15 Series IMY 15 Series
15 Watt DC-DC Converters IMX 15 Series IMY 15 Series

Galaxy High Efficiency Modes
Galaxy High Efficiency Modes

... controller, battery charger, etc. is being powered through the inverter using power from bypass. In Figure 11 the power flow in ECO Mode is shown and the inverter is not active in charging the DC bus. Figure 12 illustrates the power flow in ECOnversion Mode where the DC bus is being powered from the ...
Power Measurement Techniques For Nonsinusoidal conditions
Power Measurement Techniques For Nonsinusoidal conditions

... ones are the (total) active power and the amplitude and phase angle of individual harmonics of non-sinusoidal voltages and currents. The DSWM was first verified for sinusoidal signals. At 120 V and 5 A and power factor one, the DSWM has an estimated uncertainty (2σ) of 60 ppm at 50 Hz and 600 ppm at ...
Power Supplies
Power Supplies

EQW010-040 Series (Eighth-Brick) DC
EQW010-040 Series (Eighth-Brick) DC

... CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal ...
LTC4150 - Coulomb Counter/Battery Gas Gauge
LTC4150 - Coulomb Counter/Battery Gas Gauge

... presence of noise, spikes and ripple. 4.7μF is recommended for general applications but can be extended to higher values as long as the capacitor’s leakage is low. A 10nA leakage is roughly equivalent to the input offset error of the integrator. Ceramic capacitors are suitable for this use. Switchin ...
PDF
PDF

... The ARM modulator, coupled to a 400nm # 220nm bus waveguide, has an integrated vertical p-n junction around its edge with p and n type doping concentrations of ~2#1018 cm–3 and interior p+ and n+ contacts with doping concentrations at a level of 1#1020 cm–3 (Fig. 1, left). The coupling region, singl ...
DIGITAL SERVO PROGRAMMER HFP-20 OPERATION
DIGITAL SERVO PROGRAMMER HFP-20 OPERATION

... like any traditional servo product. However Hitec expanded the capability of our digital servos to include the ability to program your own unique performance specification parameters. Many of you will have modern computer radios that will allow you to program most of these functions, some like dead ...
SP3245E 数据资料DataSheet下载
SP3245E 数据资料DataSheet下载

... negative terminal of C2 to ground and the positive terminal of C2 to the VDD storage capacitor. This transfers the doubled (V+) voltage onto C3. Meanwhile, capacitor C1 charged from VCC to prepare it for its next phase. ...
weather proof intelli+® actuators
weather proof intelli+® actuators

... The BC Premium label is the guarantee of high performance, reliable and innovative actuator solutions designed to sustain severe environmental and operational conditions. Decades of return of experience from very demanding applications such as nuclear qualified valves actuation have shaped our techn ...
< 1 ... 111 112 113 114 115 116 117 118 119 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report