R-MAG®Medium Voltage Tank Vacuum Magnetic
... has more stroke than the vacuum interrupter and the interrupter contacts make contact before the actuator has completed the stroke. The additional movement of the operating rod after the contact closing causes the contact pressure spring to compress at the top of the operating rod. This wipe allows ...
... has more stroke than the vacuum interrupter and the interrupter contacts make contact before the actuator has completed the stroke. The additional movement of the operating rod after the contact closing causes the contact pressure spring to compress at the top of the operating rod. This wipe allows ...
MPA-460 ANF3/8031 BRUSHLESS SERVO AMPLIFIER
... inverted by switching the fourth switch on DIP switch S2. Once this is done, this output will be ON if no fault exists. This output would now be thought of as a READY output instead of a FAULT output. The normal fault operation occurs with SW6-4 ON. The purpose of inversion of this output is to allo ...
... inverted by switching the fourth switch on DIP switch S2. Once this is done, this output will be ON if no fault exists. This output would now be thought of as a READY output instead of a FAULT output. The normal fault operation occurs with SW6-4 ON. The purpose of inversion of this output is to allo ...
live-front pad-mounted switchgear
... of switch-to-enclosure alignment. A quick-make, quick-break ③The 3-time fault-close duty-cycle rating means that the device can stored energy mechanism with heavy-duty, long-life die springs, be closed three times into rated fault-current and remain operable and provides high speed opening and closi ...
... of switch-to-enclosure alignment. A quick-make, quick-break ③The 3-time fault-close duty-cycle rating means that the device can stored energy mechanism with heavy-duty, long-life die springs, be closed three times into rated fault-current and remain operable and provides high speed opening and closi ...
Trip Indication Relays - E
... relay, communication and control system operations. The TIR contacts are also used to activate alarm and/or annunciator contacts. The E-MAX Trip Indication Relays detect the presence of current in power system circuit breaker trip coils. The TIR has a current coil designed for installation in circui ...
... relay, communication and control system operations. The TIR contacts are also used to activate alarm and/or annunciator contacts. The E-MAX Trip Indication Relays detect the presence of current in power system circuit breaker trip coils. The TIR has a current coil designed for installation in circui ...
SERIES II - Dakota Digital
... A single wire should be run from the fuel sender to the control box terminal marked FUEL. If your wiring harness already has a wire routed through the vehicle for the fuel sender then it may be used. If using a wire from an existing harness, make sure that the wire does not have power. The fuel sen ...
... A single wire should be run from the fuel sender to the control box terminal marked FUEL. If your wiring harness already has a wire routed through the vehicle for the fuel sender then it may be used. If using a wire from an existing harness, make sure that the wire does not have power. The fuel sen ...
csl series - Marley Engineered Products
... ENCLOSURE - Shall be fabricated of 16 gauge cold-rolled steel (14 gauge optional), with a built-in wireway with factory installed wiring rated up to 45 amps. This makes it unnecessary to fish wires through when wiring two or more heaters in parallel. Removal of the front panel will provide unobstruc ...
... ENCLOSURE - Shall be fabricated of 16 gauge cold-rolled steel (14 gauge optional), with a built-in wireway with factory installed wiring rated up to 45 amps. This makes it unnecessary to fish wires through when wiring two or more heaters in parallel. Removal of the front panel will provide unobstruc ...
MAX1742/MAX1842 1A/2.7A, 1MHz, Step-Down Regulators with Synchronous Rectification and Internal Switches General Description
... input voltages of 3V to 5.5V to a preset output voltage of 2.5V, 1.8V, or 1.5V, or to an adjustable output voltage from 1.1V to VIN. Both devices deliver up to 1A of continuous output current; the MAX1842 delivers bursts of output current up to 2.7A (see the Extended Current Limit section). Internal ...
... input voltages of 3V to 5.5V to a preset output voltage of 2.5V, 1.8V, or 1.5V, or to an adjustable output voltage from 1.1V to VIN. Both devices deliver up to 1A of continuous output current; the MAX1842 delivers bursts of output current up to 2.7A (see the Extended Current Limit section). Internal ...
Switch
In electrical engineering, a switch is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another.The mechanism of a switch may be operated directly by a human operator to control a circuit (for example, a light switch or a keyboard button), may be operated by a moving object such as a door-operated switch, or may be operated by some sensing element for pressure, temperature or flow. A relay is a switch that is operated by electricity. Switches are made to handle a wide range of voltages and currents; very large switches may be used to isolate high-voltage circuits in electrical substations.