MAX16054 On/Off Controller with Debounce and ±15kV ESD Protection General Description
... handle ±25V levels and are ±15kV ESD protected for use in harsh industrial environments. The MAX16054 features a complementary output, OUT, which is the inverted state of OUT. An asynchronous CLEAR input allows an external signal to force the output flip-flop low. Undervoltage-lockout circuitry ensu ...
... handle ±25V levels and are ±15kV ESD protected for use in harsh industrial environments. The MAX16054 features a complementary output, OUT, which is the inverted state of OUT. An asynchronous CLEAR input allows an external signal to force the output flip-flop low. Undervoltage-lockout circuitry ensu ...
ADG3243 数据手册DataSheet 下载
... It is measured when all control inputs are at a logic high or low level and the switches are OFF. Extra power supply current component for the EN control input when the input is not driven at the supplies. Data Propagation Delay through the Switch in the ON State. Propagation delay is related to the ...
... It is measured when all control inputs are at a logic high or low level and the switches are OFF. Extra power supply current component for the EN control input when the input is not driven at the supplies. Data Propagation Delay through the Switch in the ON State. Propagation delay is related to the ...
PS1: Overcurrent Protection of a Substation Power Transformer
... using the computers available in the lab. Students can conduct the experiments at any time as long as the lab is available. Reports are due at the specified date. Preparation of the report: The report must include the following: A brief introduction to the hydrothermal coordination problem The M ...
... using the computers available in the lab. Students can conduct the experiments at any time as long as the lab is available. Reports are due at the specified date. Preparation of the report: The report must include the following: A brief introduction to the hydrothermal coordination problem The M ...
MAX4594–MAX4597 Low-Voltage, Single-Supply, 10 SPST CMOS Analog Switches
... 10Ω SPST CMOS Analog Switches The MAX4594–MAX4597 single-pole/single-throw (SPST) analog switches operate from a single +2.0V to +5.5V supply. The MAX4594/MAX4596 switches are normally open (NO), and the MAX4595/MAX4597 are normally closed (NC). The MAX4596/MAX4597 pinouts are optimized for the high ...
... 10Ω SPST CMOS Analog Switches The MAX4594–MAX4597 single-pole/single-throw (SPST) analog switches operate from a single +2.0V to +5.5V supply. The MAX4594/MAX4596 switches are normally open (NO), and the MAX4595/MAX4597 are normally closed (NC). The MAX4596/MAX4597 pinouts are optimized for the high ...
New vacuum interrupters for contactors and switches
... voltage of 12 kV, and VS4 with 24/36 kV. Both classes have the same outside dimensions as the VS2 interrupter 2 . Since, due to its extremely compact design, the external insulating distance of the VS4 does not satisfy the dielectric requirements specified in IEC 60694, either the switch compartment ...
... voltage of 12 kV, and VS4 with 24/36 kV. Both classes have the same outside dimensions as the VS2 interrupter 2 . Since, due to its extremely compact design, the external insulating distance of the VS4 does not satisfy the dielectric requirements specified in IEC 60694, either the switch compartment ...
MAX1708 datasheet
... the IF frequency band(s). High-frequency operation permits low-magnitude output ripple voltage and minimum inductor and filter capacitor size. Switching losses will increase at higher frequencies (see MAX1708 IC Power Dissipation). ...
... the IF frequency band(s). High-frequency operation permits low-magnitude output ripple voltage and minimum inductor and filter capacitor size. Switching losses will increase at higher frequencies (see MAX1708 IC Power Dissipation). ...
Evaluates: MAX8758 MAX8758 Evaluation Kit General Description Features
... to generate approximately +23V and can provide more than 20mA. The GOFF consists of a single negative charge-pump stage to generate approximately -8V and can provide more than 20mA. Loading the GON charge pump reduces the available output current on VMAIN by three times the GON load current. Loading ...
... to generate approximately +23V and can provide more than 20mA. The GOFF consists of a single negative charge-pump stage to generate approximately -8V and can provide more than 20mA. Loading the GON charge pump reduces the available output current on VMAIN by three times the GON load current. Loading ...
Switch
![](https://commons.wikimedia.org/wiki/Special:FilePath/Switches-electrical.agr.jpg?width=300)
In electrical engineering, a switch is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another.The mechanism of a switch may be operated directly by a human operator to control a circuit (for example, a light switch or a keyboard button), may be operated by a moving object such as a door-operated switch, or may be operated by some sensing element for pressure, temperature or flow. A relay is a switch that is operated by electricity. Switches are made to handle a wide range of voltages and currents; very large switches may be used to isolate high-voltage circuits in electrical substations.