1. General presentation
... technology, as far as technically possible, have to be used for single-phase or double capacitor units. Each capacitor shall be provided with a discharge resistor assembly to reduce the residual voltage to 75 volts or less within 10 minutes after the capacitor is disconnected from rated voltage. The ...
... technology, as far as technically possible, have to be used for single-phase or double capacitor units. Each capacitor shall be provided with a discharge resistor assembly to reduce the residual voltage to 75 volts or less within 10 minutes after the capacitor is disconnected from rated voltage. The ...
Tunable Sensors for Process-Aware Voltage Scaling
... Design-dependent monitor [Elgebaly07, Drake08, Chan12] ...
... Design-dependent monitor [Elgebaly07, Drake08, Chan12] ...
MC34164 MC33164 Micropower Undervoltage Sensing Circuits
... specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters which may be provided in Motorola data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating ...
... specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters which may be provided in Motorola data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating ...
Dynamic Current Profiling
... probe is typically limited to the milliampere range, it cannot capture the low current levels that are typical when a device is in sleep mode. Using some type of shunt is effective for small current ranges, but large dynamic ranges present the problem of varying measurement accuracies because you ar ...
... probe is typically limited to the milliampere range, it cannot capture the low current levels that are typical when a device is in sleep mode. Using some type of shunt is effective for small current ranges, but large dynamic ranges present the problem of varying measurement accuracies because you ar ...
1. General presentation - OPS Schneider Electric
... As a consequence, our capacitor units nameplates show these design power and design voltage values (Qdim and Vdim). Operating values can be equal or lower than these values (Qn and Vn). The documents supplied with our medium voltage products (price lists, order forms, catalogues, …) provide reactive ...
... As a consequence, our capacitor units nameplates show these design power and design voltage values (Qdim and Vdim). Operating values can be equal or lower than these values (Qn and Vn). The documents supplied with our medium voltage products (price lists, order forms, catalogues, …) provide reactive ...
maxon EC motor EC 32 flat with integrated electronics Document ID: 919778en
... Optionally, the controller can be set to 2-wire operation mode by linking (shorten) both connections speed monitor (green) and speed set value (white). Thereby, the connection must be established before applying the supply voltage. Working Principle of Detection of “2-Wire” Operating Mode with 5-Wir ...
... Optionally, the controller can be set to 2-wire operation mode by linking (shorten) both connections speed monitor (green) and speed set value (white). Thereby, the connection must be established before applying the supply voltage. Working Principle of Detection of “2-Wire” Operating Mode with 5-Wir ...
High Speed, Dual, 4 A MOSFET Driver ADP3654
... Place the VDD bypass capacitor as close as possible to the VDD and PGND pins. Use vias to other layers, when possible, to maximize thermal conduction away from the IC. ...
... Place the VDD bypass capacitor as close as possible to the VDD and PGND pins. Use vias to other layers, when possible, to maximize thermal conduction away from the IC. ...
Section 16340
... Doors providing access to interrupter switches and fuses shall be key interlocked to guard against opening the door if the interrupter switch on the source side of the switch is closed and closing the interrupter switch if the door is open. B. Motor Operators - Switches shall be supplied with motor ...
... Doors providing access to interrupter switches and fuses shall be key interlocked to guard against opening the door if the interrupter switch on the source side of the switch is closed and closing the interrupter switch if the door is open. B. Motor Operators - Switches shall be supplied with motor ...
- Yokogawa
... related applications, measuring the power consumption and performance of the individual components alone is often not sufficient to understand the overall performance and behavior of a system. A ScopeCorder satisfies this new measurement requirement by not only capturing voltage and current waveform ...
... related applications, measuring the power consumption and performance of the individual components alone is often not sufficient to understand the overall performance and behavior of a system. A ScopeCorder satisfies this new measurement requirement by not only capturing voltage and current waveform ...
MSi2500 - Mirics.com
... such that the load capacitors are twice the crystal load capacitance minus any stray capacitance. The load capacitance effectively limits the voltage swing at X0 which degrades phase noise of the REFOUT output. This in turn degrades the RF phase noise of the tuner and system performance. A good RF S ...
... such that the load capacitors are twice the crystal load capacitance minus any stray capacitance. The load capacitance effectively limits the voltage swing at X0 which degrades phase noise of the REFOUT output. This in turn degrades the RF phase noise of the tuner and system performance. A good RF S ...
Model No. 100-101 - Lake Shore Cryotronics, Inc.
... The Models 100 and 101 battery-powered DC current sources provide very stable output current without noise commonly associated with AC line-powered instruments. They combine the convenience of a portable, hand-held device and the performance of a benchtop unit. They are well-suited for field mainten ...
... The Models 100 and 101 battery-powered DC current sources provide very stable output current without noise commonly associated with AC line-powered instruments. They combine the convenience of a portable, hand-held device and the performance of a benchtop unit. They are well-suited for field mainten ...
A plane can be uniquely determined by three non
... TCP has for instance been developed to discard duplicates. Applications using UDP must be able to treat duplicates since UDP is a connection-less protocol. However, discarding duplicates at the link layer level allows to offload the application processor and to provide network supervision. Since it ...
... TCP has for instance been developed to discard duplicates. Applications using UDP must be able to treat duplicates since UDP is a connection-less protocol. However, discarding duplicates at the link layer level allows to offload the application processor and to provide network supervision. Since it ...
Design of an Arduino based Maximum Power Point Tracking (MPPT
... She has guided us all the way through despite her busy schedule Miss Shoilie has always managed to take out that time and guide us through. We were privileged enough to have been assisted and guided by them throughout this thesis. ...
... She has guided us all the way through despite her busy schedule Miss Shoilie has always managed to take out that time and guide us through. We were privileged enough to have been assisted and guided by them throughout this thesis. ...
TS1005 - Silicon Labs
... are stress ratings only and functional operation of the device at these or any other condition beyond those indicated in the operational sections of the specifications is not implied. Exposure to any absolute maximum rating conditions for extended periods may affect device reliability and ...
... are stress ratings only and functional operation of the device at these or any other condition beyond those indicated in the operational sections of the specifications is not implied. Exposure to any absolute maximum rating conditions for extended periods may affect device reliability and ...
Enquiry Form (Non-Registered Generator With Capacity less than 5
... interval based on calculated or measured. This needs to reflect the maximum generator export during facility minimum self-consumption period. (kW or kVA). Confirm presence (Y/N) of any other disturbing load/system with potential to disturb the voltage waveform and or power quality, such as: PFC, DOL ...
... interval based on calculated or measured. This needs to reflect the maximum generator export during facility minimum self-consumption period. (kW or kVA). Confirm presence (Y/N) of any other disturbing load/system with potential to disturb the voltage waveform and or power quality, such as: PFC, DOL ...
High-Voltage, High-Current OPERATIONAL AMPLIFIER DESCRIPTION FEATURES
... The OPA547 is a low-cost, high-voltage/high-current operational amplifier ideal for driving a wide variety of loads. A laser-trimmed monolithic integrated circuit provides excellent low-level signal accuracy and high output voltage and current. The OPA547 operates from either single or dual supplies ...
... The OPA547 is a low-cost, high-voltage/high-current operational amplifier ideal for driving a wide variety of loads. A laser-trimmed monolithic integrated circuit provides excellent low-level signal accuracy and high output voltage and current. The OPA547 operates from either single or dual supplies ...
User's Manual PQP-A Energotester Edition 1
... electrical values and power quality parameters (hereinafter referred to as PQP) in power networks . The UM describes their operation, maintenance, transportation, storage, and manufacturer's warranty conditions. The UM also includes information about the calibration procedure, packing form and accep ...
... electrical values and power quality parameters (hereinafter referred to as PQP) in power networks . The UM describes their operation, maintenance, transportation, storage, and manufacturer's warranty conditions. The UM also includes information about the calibration procedure, packing form and accep ...
R.P. Pilawa-Podgurski, W. Li, I. Celanovic and D.J. Perreault, “Integrated CMOS Energy Harvesting Converter with Digital Maximum Power Point Tracking for a Portable Thermophotovoltaic Power Generator,” IEEE Journal of Emerging and Selected Topics in Power Electronics , Vol. 3, No. 4, pp. 1021-1035, August 2015.
... voltage Vstring can be controlled to equal VMP P at all times. The dc-dc converter, acting as a maximum power point tracker (MPPT), continuously tracks VMP P by adjusting its conversion ratio in response to changes in operating conditions. The method of Figure 3b is often adequate for solar photovol ...
... voltage Vstring can be controlled to equal VMP P at all times. The dc-dc converter, acting as a maximum power point tracker (MPPT), continuously tracks VMP P by adjusting its conversion ratio in response to changes in operating conditions. The method of Figure 3b is often adequate for solar photovol ...