PS9306L,PS9306L2 Data Sheet Preliminary
... (1) By-pass capacitor of more than 0.1 μF is used between VCC and GND near device. Also, ensure that the distance between the leads of the photocoupler and capacitor is no more than 10 mm. (2) When designing the printed wiring board, ensure that the pattern of the IGBT collectors/emitters is not too ...
... (1) By-pass capacitor of more than 0.1 μF is used between VCC and GND near device. Also, ensure that the distance between the leads of the photocoupler and capacitor is no more than 10 mm. (2) When designing the printed wiring board, ensure that the pattern of the IGBT collectors/emitters is not too ...
ADP1850 数据手册DataSheet 下载
... Sets the desired operating frequency between 200 kHz and 1.5 MHz with one resistor between FREQ and AGND. Connect FREQ to AGND for a preprogrammed 300 kHz or FREQ to VCCO for 600 kHz operating frequency. Enable Input for Channel 2. Drive EN2 high to turn on the Channel 2 controller, and drive EN2 lo ...
... Sets the desired operating frequency between 200 kHz and 1.5 MHz with one resistor between FREQ and AGND. Connect FREQ to AGND for a preprogrammed 300 kHz or FREQ to VCCO for 600 kHz operating frequency. Enable Input for Channel 2. Drive EN2 high to turn on the Channel 2 controller, and drive EN2 lo ...
North Carolina Electric Membership Corporation Facility Connection
... capability data needed to evaluate the compatibility of the proposed facility interconnection with the BES. 2.1.5. System Protection and Coordination NCEMC’s system protection requirements are intended to protect NCEMC’s transmission and generation systems from equipment damage, to ensure the safety ...
... capability data needed to evaluate the compatibility of the proposed facility interconnection with the BES. 2.1.5. System Protection and Coordination NCEMC’s system protection requirements are intended to protect NCEMC’s transmission and generation systems from equipment damage, to ensure the safety ...
Lecture 11 - The University of Arizona College of Optical Sciences
... → Wall “plug-in” transformers (“a.k.a. wall-warts) can supply either an AC or a DC voltage…!?! Dr. Mike Nofziger 2014 Lecture 11 ...
... → Wall “plug-in” transformers (“a.k.a. wall-warts) can supply either an AC or a DC voltage…!?! Dr. Mike Nofziger 2014 Lecture 11 ...
MAX3053 ±80V Fault-Protected, 2Mbps, Low Supply Current CAN Transceiver General Description
... (CANH, CANL) and converts this data to a singleended output (RXD) to the CAN controller. It consists of a comparator that senses the difference ∆V = (CANH CANL) with respect to an internal threshold of 0.7V. If this difference is positive (i.e., ∆V > 0.9V), a logic low is present at the RXD pin. If ...
... (CANH, CANL) and converts this data to a singleended output (RXD) to the CAN controller. It consists of a comparator that senses the difference ∆V = (CANH CANL) with respect to an internal threshold of 0.7V. If this difference is positive (i.e., ∆V > 0.9V), a logic low is present at the RXD pin. If ...
Resistors - La Salle University
... If it bothers you that the resistance of two resistors in parallel is lower than either resistor, consider the following. A fire starts in a packed theatre and there is one door through which everyone must exit. It’s a difficult task to get everyone out. A second exit is found, the second exit i ...
... If it bothers you that the resistance of two resistors in parallel is lower than either resistor, consider the following. A fire starts in a packed theatre and there is one door through which everyone must exit. It’s a difficult task to get everyone out. A second exit is found, the second exit i ...
SA-600R Series Pure Sine Wave Inverter User`s Manual
... To operate the power inverter, use the ON / OFF switch on the Front panel to turn the power on. Then the power inverter is ready to deliver AC power to the loads. If you are operating several loads from the power inverter, turn them on separately after the inverter is on. This will ensure that the p ...
... To operate the power inverter, use the ON / OFF switch on the Front panel to turn the power on. Then the power inverter is ready to deliver AC power to the loads. If you are operating several loads from the power inverter, turn them on separately after the inverter is on. This will ensure that the p ...
Atmel ATA6843/ATA6844 BLDC Motor Driver and LIN System Basis Chip Features DATASHEET
... After power-up of the VCC regulator (VCC output exceeds 88% of its nominal value) /RESET output stays LOW for the timeout period tres (typical 10ms). Subsequently /RESET output switches to HIGH. During the following time td (typical 500ms) a rising edge at the input WD is expected otherwise another ...
... After power-up of the VCC regulator (VCC output exceeds 88% of its nominal value) /RESET output stays LOW for the timeout period tres (typical 10ms). Subsequently /RESET output switches to HIGH. During the following time td (typical 500ms) a rising edge at the input WD is expected otherwise another ...
Old Company Name in Catalogs and Other Documents
... subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be d ...
... subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office. Also, please pay regular and careful attention to additional and different information to be d ...
Op-Amp Voltage Amplifiers Word Document
... Voltage gain can be determined if either VOUT and VIN are known or if RF and RIN are known. The ‘-‘ sign in the formula indicates the inverting action of this amplifier, so at any moment if the input voltage is positive, the output will be negative, and vice versa. If you are designing an amplifier ...
... Voltage gain can be determined if either VOUT and VIN are known or if RF and RIN are known. The ‘-‘ sign in the formula indicates the inverting action of this amplifier, so at any moment if the input voltage is positive, the output will be negative, and vice versa. If you are designing an amplifier ...
Operating Manual
... Thyristor switching modules of the KATKA line have been designed especially for switching power factor correction capacitors in rapid reactive power compensation (up to 20 control interventions in one second) in conjunction with fast power factor controllers of the NOVAR line. They can, of course, b ...
... Thyristor switching modules of the KATKA line have been designed especially for switching power factor correction capacitors in rapid reactive power compensation (up to 20 control interventions in one second) in conjunction with fast power factor controllers of the NOVAR line. They can, of course, b ...
FZT558 Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
mc1488, sn55188, sn75188 quadruple line drivers
... Texas Instruments (TI) reserves the right to make changes to its products or to discontinue any semiconductor product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the information being relied on is cu ...
... Texas Instruments (TI) reserves the right to make changes to its products or to discontinue any semiconductor product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the information being relied on is cu ...
2.5 V/3.0 V High Precision Reference AD780
... The long-term stability specification is noncumulative. The drift in subsequent 1,000 hour periods is significantly lower than in the first 1,000 hour period. ...
... The long-term stability specification is noncumulative. The drift in subsequent 1,000 hour periods is significantly lower than in the first 1,000 hour period. ...
AD8038
... *Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to a ...
... *Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to a ...
ZXMN6A07F Product Summary Features
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Hybrid Multilevel Power Conversion System: A Competitive Solution for High-Power Applications
... spectrum and attain higher voltages with a limited maximum device rating. In the family of multilevel inverters, topologies based on series-connected H-bridges are particularly attractive because of their modularity and simplicity of control [3]. Such H-bridge multilevel inverters have also been imp ...
... spectrum and attain higher voltages with a limited maximum device rating. In the family of multilevel inverters, topologies based on series-connected H-bridges are particularly attractive because of their modularity and simplicity of control [3]. Such H-bridge multilevel inverters have also been imp ...
0.35W x 2ch, Class AB, Power Amplifier IC for Low Power
... This capacitor C5 is designed for the ripple filter. Its purpose is to make up a low-pass filter with a 100kΩ internal resistor for reducing the ripple component of the power supply and improve the ripple rejection ratio. Inside the IC, the startup characteristics of the pin 10 voltage are used to d ...
... This capacitor C5 is designed for the ripple filter. Its purpose is to make up a low-pass filter with a 100kΩ internal resistor for reducing the ripple component of the power supply and improve the ripple rejection ratio. Inside the IC, the startup characteristics of the pin 10 voltage are used to d ...
AD8571
... 6/08—Rev. C to Rev. D Changes to Figure 19 and Figure 20 ............................................... 8 Changes to Figure 44 ...................................................................... 12 Changes to Figure 38 ...................................................................... 13 Mov ...
... 6/08—Rev. C to Rev. D Changes to Figure 19 and Figure 20 ............................................... 8 Changes to Figure 44 ...................................................................... 12 Changes to Figure 38 ...................................................................... 13 Mov ...
MAX8600/MAX8601 Single-/Dual-Input 1-Cell Li+ Chargers with OVP Protection and Programmable Charge Timer
... The MAX8600/MAX8601 single-/dual-input linear battery chargers safely charge single-cell Li+ batteries. The charging rate is optimized to accommodate the thermal characteristics of a given application. There is no need to reduce the maximum charge current or worst-case charger power dissipation. Cha ...
... The MAX8600/MAX8601 single-/dual-input linear battery chargers safely charge single-cell Li+ batteries. The charging rate is optimized to accommodate the thermal characteristics of a given application. There is no need to reduce the maximum charge current or worst-case charger power dissipation. Cha ...
MAX1909/MAX8725 Multichemistry Battery Chargers with Automatic System Power Selector General Description
... DLOV to LDO.........................................................-0.3V to +0.3V DLO to PGND ..........................................-0.3V to (DLOV + 0.3V) LDO Short-Circuit Current...................................................50mA Continuous Power Dissipation (TA = +70°C) 28-Pin TQFN (dera ...
... DLOV to LDO.........................................................-0.3V to +0.3V DLO to PGND ..........................................-0.3V to (DLOV + 0.3V) LDO Short-Circuit Current...................................................50mA Continuous Power Dissipation (TA = +70°C) 28-Pin TQFN (dera ...
Surge protector
A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".