AD8571
... 6/08—Rev. C to Rev. D Changes to Figure 19 and Figure 20 ............................................... 8 Changes to Figure 44 ...................................................................... 12 Changes to Figure 38 ...................................................................... 13 Mov ...
... 6/08—Rev. C to Rev. D Changes to Figure 19 and Figure 20 ............................................... 8 Changes to Figure 44 ...................................................................... 12 Changes to Figure 38 ...................................................................... 13 Mov ...
Understanding Motor Driver Current Ratings
... 25°C ambient temperature, when mounted on a standard JEDEC-specified PCB, before it enters overtemperature protection. This current level is not attained at higher ambient temperatures, or on PCB layouts that are not as good at dissipating power as the standard JEDEC PCB. In the actual application, ...
... 25°C ambient temperature, when mounted on a standard JEDEC-specified PCB, before it enters overtemperature protection. This current level is not attained at higher ambient temperatures, or on PCB layouts that are not as good at dissipating power as the standard JEDEC PCB. In the actual application, ...
MAX1909/MAX8725 Multichemistry Battery Chargers with Automatic System Power Selector General Description
... DLOV to LDO.........................................................-0.3V to +0.3V DLO to PGND ..........................................-0.3V to (DLOV + 0.3V) LDO Short-Circuit Current...................................................50mA Continuous Power Dissipation (TA = +70°C) 28-Pin TQFN (dera ...
... DLOV to LDO.........................................................-0.3V to +0.3V DLO to PGND ..........................................-0.3V to (DLOV + 0.3V) LDO Short-Circuit Current...................................................50mA Continuous Power Dissipation (TA = +70°C) 28-Pin TQFN (dera ...
MAX1762/MAX1791 High-Efficiency, 10-Pin µMAX, Step-Down Controllers for Notebooks General Description
... The standard application circuit (Figure 1) generates a low-voltage output for general-purpose use in notebook computers (I/O supply, fixed CPU, core supply, and DRAM supply). This DC-DC converter steps down battery voltage from 5V to 20V with high efficiency and accuracy to a fixed voltage of 1.8V/ ...
... The standard application circuit (Figure 1) generates a low-voltage output for general-purpose use in notebook computers (I/O supply, fixed CPU, core supply, and DRAM supply). This DC-DC converter steps down battery voltage from 5V to 20V with high efficiency and accuracy to a fixed voltage of 1.8V/ ...
ADP1877 英文数据手册DataSheet 下载
... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to ...
... Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to ...
Impacts of Various Representations of Core Saturation Curve
... source side, the transformer is still fed through the capacitive coupling Cc between the two circuits of the transmission system, Fig. 8. It is well documented that such a configuration is favorable to ferroresonance [15],[16]. When the system of Fig. 8 with the no-load transformer T1 are in the nor ...
... source side, the transformer is still fed through the capacitive coupling Cc between the two circuits of the transmission system, Fig. 8. It is well documented that such a configuration is favorable to ferroresonance [15],[16]. When the system of Fig. 8 with the no-load transformer T1 are in the nor ...
BD14000EFV-C Datasheet
... When using both small-signal and large-current ground traces, the two ground traces should be routed separately but connected to a single ground at the reference point of the application board to avoid fluctuations in the small-signal ground caused by large currents. Also ensure that the ground trac ...
... When using both small-signal and large-current ground traces, the two ground traces should be routed separately but connected to a single ground at the reference point of the application board to avoid fluctuations in the small-signal ground caused by large currents. Also ensure that the ground trac ...
0.35W x 2ch, Class AB, Power Amplifier IC for Low Power
... This capacitor C5 is designed for the ripple filter. Its purpose is to make up a low-pass filter with a 100kΩ internal resistor for reducing the ripple component of the power supply and improve the ripple rejection ratio. Inside the IC, the startup characteristics of the pin 10 voltage are used to d ...
... This capacitor C5 is designed for the ripple filter. Its purpose is to make up a low-pass filter with a 100kΩ internal resistor for reducing the ripple component of the power supply and improve the ripple rejection ratio. Inside the IC, the startup characteristics of the pin 10 voltage are used to d ...
Optimum Design of Magnetic Inductive Energy Harvester and its AC-DC Converter
... where step-up transformers cannot be used directly because of their large size. At the same time, the voltage requirement for low voltage, low power, electronic devices is typically 1.8~3.3VDC. Thus, rectification losses cannot be avoided in power processing circuit of magnetic harvester. Recently, ...
... where step-up transformers cannot be used directly because of their large size. At the same time, the voltage requirement for low voltage, low power, electronic devices is typically 1.8~3.3VDC. Thus, rectification losses cannot be avoided in power processing circuit of magnetic harvester. Recently, ...
CHAPTER 4 BIPOLAR JUNCTION TRANSISTORS (BJTs)
... CE amplifier can provide high voltage gain Input and output are in‐phase due to positive gain Input resistance is very low A single CB stage is not suitable for voltage amplification Output resistance is moderate to high Small RC reduces Ro at the cost of voltage gain The amplifier is no long ...
... CE amplifier can provide high voltage gain Input and output are in‐phase due to positive gain Input resistance is very low A single CB stage is not suitable for voltage amplification Output resistance is moderate to high Small RC reduces Ro at the cost of voltage gain The amplifier is no long ...
_______________General Description ____________________________Features
... INO = 1.0mA, VCOM = ±10V INO = 1.0mA, VCOM = ±10V ...
... INO = 1.0mA, VCOM = ±10V INO = 1.0mA, VCOM = ±10V ...
Electricity
... two spheres is attached. When the second sphere is brought into close proximity with the first, the force acting between the two charged spheres produces torsion of the wires; this can be indicated and measured using a light pointer. The balance must be calibrated if the force is to be measured in a ...
... two spheres is attached. When the second sphere is brought into close proximity with the first, the force acting between the two charged spheres produces torsion of the wires; this can be indicated and measured using a light pointer. The balance must be calibrated if the force is to be measured in a ...
ZXGD3101N8 Description Features
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
LT1641-1/LT1641-2 - Positive high Voltage Hot Swap Controllers
... while R5 prevents high frequency oscillations in Q1. Resistors R1 and R2 provide undervoltage sensing. After the power pins first make contact, transistor Q1 is turned off. If the voltage at the ON pin exceeds the turn-on threshold voltage, the voltage on the VCC pin exceeds the undervoltage lockout ...
... while R5 prevents high frequency oscillations in Q1. Resistors R1 and R2 provide undervoltage sensing. After the power pins first make contact, transistor Q1 is turned off. If the voltage at the ON pin exceeds the turn-on threshold voltage, the voltage on the VCC pin exceeds the undervoltage lockout ...
Capture Energy by Circuit Breaker Communication
... products and engineering services for energy distribution, safe and uninterrupted power supply, machine and building automation, system and motor protection, lighting, safety and cable management, as well as components for harsh ambient conditions and areas at risk of explosion. With its global solu ...
... products and engineering services for energy distribution, safe and uninterrupted power supply, machine and building automation, system and motor protection, lighting, safety and cable management, as well as components for harsh ambient conditions and areas at risk of explosion. With its global solu ...
AD829 Data Sheet
... 8-lead plastic package: θJA = 100°C/watt (derate at 8.7 mW/°C) 8-lead cerdip package: θJA = 110°C/watt (derate at 8.7 mW/°C) 20-lead LCC package: θJA = 150°C/watt 8-lead small outline package: θ JA = 155°C/watt (derate at 6 mW/°C). ...
... 8-lead plastic package: θJA = 100°C/watt (derate at 8.7 mW/°C) 8-lead cerdip package: θJA = 110°C/watt (derate at 8.7 mW/°C) 20-lead LCC package: θJA = 150°C/watt 8-lead small outline package: θ JA = 155°C/watt (derate at 6 mW/°C). ...
Electricity – Simple Circuits
... circuit. Record which materials let electricity through (the bulb lights if electricity flows). ...
... circuit. Record which materials let electricity through (the bulb lights if electricity flows). ...
AD8063
... AD8061/AD8062/AD8063 is limited by the associated rise in junction temperature. The maximum safe junction temperature for plastic encapsulated devices is determined by the glass transition temperature of the plastic, approximately 150°C. Temporarily exceeding this limit may cause a shift in parametr ...
... AD8061/AD8062/AD8063 is limited by the associated rise in junction temperature. The maximum safe junction temperature for plastic encapsulated devices is determined by the glass transition temperature of the plastic, approximately 150°C. Temporarily exceeding this limit may cause a shift in parametr ...
EEE 107-3240
... fluorescent lamps (CFLS), etc., will further degrade distribution system power quality. To compensate distribution system harmonic distortions, a number of active and passive filtering methods have been developed [3]. However, installing additional filters is not very favorable due to cost concerns. ...
... fluorescent lamps (CFLS), etc., will further degrade distribution system power quality. To compensate distribution system harmonic distortions, a number of active and passive filtering methods have been developed [3]. However, installing additional filters is not very favorable due to cost concerns. ...
Surge protector
A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".