• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SIOV metal oxide varistors, General technical information
SIOV metal oxide varistors, General technical information

... Despite its many benefits, one of the few drawbacks of semiconductor technology is the vulnerability of solid-state devices to overvoltages. Even voltage pulses of very low energy can produce interference and damage, sometimes with far-reaching consequences. So, as electronics makes its way into mor ...
lab sheet - Faculty of Engineering
lab sheet - Faculty of Engineering

... a) Compute theoretically the values of total power for all cases following table 2.1. b) For the case covered by section 2.2.1, Based on the phasor diagram given in the theory showing all the voltages and currents, draw the phasor of VCB (in star connection). Find the phase angle between the voltage ...
V - Wappingers Central School District
V - Wappingers Central School District

... To go from the top to the bottom floor, all people must take the same path. So, by definition, the staircases are in series. With each flight people lose some of the potential energy given to them by the elevator, expending all of it by the time they reach the ground floor. So the sum of the V drops ...
Lab 1 - UCSD CSE
Lab 1 - UCSD CSE

... measuring AC and DC values. If you examine the front panel, you will find primary functions are selected using a multi-position knob. Functions are accessed by selecting the desired measurement. For example, to measure DC voltage, you select the DC V option. To measure DC current, you option DC A (o ...


... voltage frequency and phase allows electrical systems to function in their intended manner without significant loss of performance or life. The term is used to describe electric power that drives an electrical load and the load's ability to function properly. Without the proper power, an electrical ...
A variable step-down conversion ratio switched capacitor DC–DC
A variable step-down conversion ratio switched capacitor DC–DC

CK series Mid-Priced CMOS IC Time Delay Relay
CK series Mid-Priced CMOS IC Time Delay Relay

... * If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: A dry circuit switch is recommended. A “dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for othe ...
PDF (Size: 146K)
PDF (Size: 146K)

... (b) Lamp B is rated at 6.0 V. When it operates at its rated voltage, the current in it is 3.0 A. Lamps A and B are connected in a circuit as shown below. The values of R1 and R2 are chosen so that both lamps operate at their rated voltage. 15 V ...
PHYSICS 536 First Laboratory: Introduction to Instruments
PHYSICS 536 First Laboratory: Introduction to Instruments

... Frequency: 10KHz (dial on 10, multiplier on x1k) Amplitude: press the 1V button, small knob on 10 Switch set for square-wave output 1. Connect the “1 volt” signal and the output signal to scope channels 1 and 2, respectively. Adjust the vertical position control as needed. You should see a sine wave ...
SME-AC-DC - khurramkamal
SME-AC-DC - khurramkamal

... If the opposite charges are constant, such as with the terminals in a battery, the current is called direct current or DC electricity, because it is going one direction. If the terminals constantly switch their polarity from (+) to (-) and back again, the direction of the electrons alternates and is ...
SG6105A Power Supply Supervisor + Regulator + PWM upervisor+Re
SG6105A Power Supply Supervisor + Regulator + PWM upervisor+Re

... for a period of time, such as 200µs, the PG (powergood) signal is pulled low to indicate an AC line powerdown condition. The voltage amplitude of the PWM switching signal in the secondary power transformer is proportional to the AC line voltage. Adjust the ratio of resistor divider to decide the thr ...
AN-202 A Digital Multimeter Using the ADD3501
AN-202 A Digital Multimeter Using the ADD3501

... TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI ...
PHYSICS 536 First Laboratory: Introduction to Instruments
PHYSICS 536 First Laboratory: Introduction to Instruments

... Frequency: 10KHz (dial on 10, multiplier on x1k) Amplitude: press the 1V button, small knob on 10 Switch set for square-wave output 1. Connect the “1 volt” signal and the output signal to scope channels 1 and 2, respectively. Adjust the vertical position control as needed. You should see a sine wave ...
ZLDO500 • 5.0 VOLT ULTRA LOW DROPOUT REGULATOR
ZLDO500 • 5.0 VOLT ULTRA LOW DROPOUT REGULATOR

... suitable for a wide range of battery powered applications where intermittent operation occurs. The shutdown control pin should not ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331

... convert the positive input source voltage to positive and negative output voltages. They consist of two conversion paths, one is positive conversion path and the other is a negative conversion path. These mirror symmetrical double-output voltages are especially required in industrial applications an ...
Aalborg Universitet Control of Grid Converters
Aalborg Universitet Control of Grid Converters

... reference is fixed, and set to a level that allows the converter operation over the entire power and grid voltage range. However, decreasing the energy stored in the dc-link can benefit the efficiency of both grid and generator converters due to reduced switching losses [4]. Also for some applicatio ...
A Diode Psychrometer for Remote Measurement of Screen Dry
A Diode Psychrometer for Remote Measurement of Screen Dry

... During operation each diode control unit draws about 10 - 12 rnA current. ...
Electric Power Quality : Types , and Measurements
Electric Power Quality : Types , and Measurements

... * Identify categories of monitoring equipment that can be used to measure power quality variations. * Offer examples of different methods for presenting the results of power quality measurements, and * Describe tools for analyzing and presenting the power quality measurement results. Analysis tools ...
Low Noise Amplifier Circuit
Low Noise Amplifier Circuit

AMICSA2016_B_Ferguson
AMICSA2016_B_Ferguson

resASS
resASS

... Incomplete, criteria unsatisfactorily carried out. No formulae used, little or No calculations and working out, all answers incorrect. The work is handed in late. RE-SUBMISSION A fail or referral grade may be re-submitted with additional work on the understanding that no higher grade than a pass may ...
Heater board troubleshooting
Heater board troubleshooting

... Heater board troubleshooting Measurement & adjustment of heater board parameters MJC 2010.05.13 ...
XTR8117 数据资料 dataSheet 下载
XTR8117 数据资料 dataSheet 下载

... XTR117 to as low as practical. Various zener diode and surge clamping diodes are specially designed for this purpose. Select a clamp diode with as low a voltage rating as possible for best protection. Absolute maximum power-supply rating on the XTR117 is specified at +50V. Keep overvoltages and tran ...
Highport Marina - Boat Slips Lake Front Restaurant Service boat
Highport Marina - Boat Slips Lake Front Restaurant Service boat

... seizure: Currents on the order of 50 milliamps (0.05 amps) sustained for 2 seconds, or 500 milliamps sustained for just 0.2 seconds, can, in certain circumstances, cause ventricular fibrillation; currents as low as 5 milliamps can cause muscle seizure. But for voltage present: Reports indicate that ...
nti-power_quality_at.. - IDEAL INDUSTRIES, INC.
nti-power_quality_at.. - IDEAL INDUSTRIES, INC.

... How do we compare voltage over time to these Standards If outside the range, timer starts, measures in cycles per second to the end of the event are taking. • When an event is detected, – The voltage of the event should be logged – The duration of the event should be logged – The day/date/time to th ...
< 1 ... 1010 1011 1012 1013 1014 1015 1016 1017 1018 ... 1574 >

Surge protector



A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report