TPS61021A 3-A Boost Converter with 0.5
... When the input voltage is above the under-voltage lockout (UVLO) rising threshold and the EN pin is pulled to logic high voltage, the TPS61021A is enabled and starts up. At the beginning, the switching frequency and current limit are internally controlled. The load capability is limited. After the o ...
... When the input voltage is above the under-voltage lockout (UVLO) rising threshold and the EN pin is pulled to logic high voltage, the TPS61021A is enabled and starts up. At the beginning, the switching frequency and current limit are internally controlled. The load capability is limited. After the o ...
CS244- Introduction to embedded systems and ubiquitous
... Convert a command to a physical stimulus (e.g., heat, light, sound, pressure, magnetism, or other mechanical motion) May require analog interface ...
... Convert a command to a physical stimulus (e.g., heat, light, sound, pressure, magnetism, or other mechanical motion) May require analog interface ...
TRANSFORMER RECTIFIER - Variac - oil immersed oil
... flame spray, epoxy seal coat, polyurethane top coat in colour RAL 7036 gloss. However, almost any specification of material, coating or IP rating can be accommodated. Enclosures are fitted with galvanized sunshade for outdoor installations, lifting hooks and earth stud. Transformer Rectifiers are su ...
... flame spray, epoxy seal coat, polyurethane top coat in colour RAL 7036 gloss. However, almost any specification of material, coating or IP rating can be accommodated. Enclosures are fitted with galvanized sunshade for outdoor installations, lifting hooks and earth stud. Transformer Rectifiers are su ...
Fluke 1750 Three-Phase Power Recorder
... powers current probes without needing batteries. Requiring only single-lead voltage connections enables safe and quick setups. Once power is applied the instrument automatically begins recording and LEDs give you assurance that the recorder is powered up and signals are within range – no more unce ...
... powers current probes without needing batteries. Requiring only single-lead voltage connections enables safe and quick setups. Once power is applied the instrument automatically begins recording and LEDs give you assurance that the recorder is powered up and signals are within range – no more unce ...
° µ REF3112 REF3120
... Supply voltages below the specified levels can cause the REF31xx to momentarily draw currents greater than the typical quiescent current. This can be prevented by using a power supply with a fast rising edge and low output impedance. ...
... Supply voltages below the specified levels can cause the REF31xx to momentarily draw currents greater than the typical quiescent current. This can be prevented by using a power supply with a fast rising edge and low output impedance. ...
OPA251 Single-Supply, POWER OPERATIONAL AMPLIFIERS
... The OPA241 series is optimized for operation at low power supply voltage while the OPA251 series is optimized for high power supplies. Both can operate from either single (+2.7V to +36V) or dual supplies (±1.35V to ±18V). The input common-mode voltage range extends 200mV below the negative supply—id ...
... The OPA241 series is optimized for operation at low power supply voltage while the OPA251 series is optimized for high power supplies. Both can operate from either single (+2.7V to +36V) or dual supplies (±1.35V to ±18V). The input common-mode voltage range extends 200mV below the negative supply—id ...
Part 1: Harmonics
... Minimal current value to be measured => 0.046 / 20 = 0.0023 A This will result in: For an estimated current measuring range of 50A => 50 A/ 0.0023 A = 21,740 => 215 or in more practical terms: AD-converter with 16 Bit resolution. ...
... Minimal current value to be measured => 0.046 / 20 = 0.0023 A This will result in: For an estimated current measuring range of 50A => 50 A/ 0.0023 A = 21,740 => 215 or in more practical terms: AD-converter with 16 Bit resolution. ...
Transmission Lines Physics 623
... a suitable resistor to a voltage of about +3V.] The signal of voltage E injected on the left passes through a resistor with resistance R = Z0 before it reaches the transmission line. Thus for the first few nanoseconds, the signal on the cable is 0.5E. This signal travels to the far end where it boun ...
... a suitable resistor to a voltage of about +3V.] The signal of voltage E injected on the left passes through a resistor with resistance R = Z0 before it reaches the transmission line. Thus for the first few nanoseconds, the signal on the cable is 0.5E. This signal travels to the far end where it boun ...
A New Induction Motor V/F Control Method using Dspic30f5011
... drive using V/F control is shown in Fig. 3[6]. It has three phase full bridge rectifier, three phase full bridge inverter, control circuit, speed sensing circuit and output filter. In the proposed work, single phase KBPC3510 Rectifier Module is used instead of power diodes. Two single phase bridge r ...
... drive using V/F control is shown in Fig. 3[6]. It has three phase full bridge rectifier, three phase full bridge inverter, control circuit, speed sensing circuit and output filter. In the proposed work, single phase KBPC3510 Rectifier Module is used instead of power diodes. Two single phase bridge r ...
SUNYUAN SZ ISO Series Analog signal Isolation Transmitter The
... equipments like in machine, machine tools, etc. Analog sensor transforms different physical quantities (e.g.:pressure, flow rate, temperature) into analog quantities (4-20mA current/ 1-5V voltage). Analog sensor as the analog input module usually used in process control to input signal. Digital sens ...
... equipments like in machine, machine tools, etc. Analog sensor transforms different physical quantities (e.g.:pressure, flow rate, temperature) into analog quantities (4-20mA current/ 1-5V voltage). Analog sensor as the analog input module usually used in process control to input signal. Digital sens ...
AN82 - Understanding and Applying Voltage
... into NC, trim and other sensitive pins through conductive flux residues will cause output voltage shifts. Even if the leakage paths do not shift the reference out of spec, external leakage can manifest itself as long-term output voltage drift, as the resistance of the flux residue changes with shift ...
... into NC, trim and other sensitive pins through conductive flux residues will cause output voltage shifts. Even if the leakage paths do not shift the reference out of spec, external leakage can manifest itself as long-term output voltage drift, as the resistance of the flux residue changes with shift ...
A Novel Bridgeless Buck
... and the cost issue, it is generally unacceptable for an efficient design. The optical coupler is also a good candidate for the voltage sensing, because it can easily achieve isolation. To achieve lower distortion of the voltage sensing, higher linearity optical coupler with wide operating range need ...
... and the cost issue, it is generally unacceptable for an efficient design. The optical coupler is also a good candidate for the voltage sensing, because it can easily achieve isolation. To achieve lower distortion of the voltage sensing, higher linearity optical coupler with wide operating range need ...
MAX78700 Multichannel, Isolated, Precision ADC General Description Benefits and Features
... The device continuously sends ADC data to the host. The host can request the device to return certain ancillary data such as trim information and die temperature data. The MAX78700 communicates with the host through a pulse transformer to provide isolation from the high-voltage power domain. ...
... The device continuously sends ADC data to the host. The host can request the device to return certain ancillary data such as trim information and die temperature data. The MAX78700 communicates with the host through a pulse transformer to provide isolation from the high-voltage power domain. ...
Resistive opto-isolator
Resistive opto-isolator (RO), also called photoresistive opto-isolator, vactrol (after a genericized trademark introduced by Vactec, Inc. in the 1960s), analog opto-isolator or lamp-coupled photocell, is an optoelectronic device consisting of a source and detector of light, which are optically coupled and electrically isolated from each other. The light source is usually a light-emitting diode (LED), a miniature incandescent lamp, or sometimes a neon lamp, whereas the detector is a semiconductor-based photoresistor made of cadmium selenide (CdSe) or cadmium sulfide (CdS). The source and detector are coupled through a transparent glue or through the air.Electrically, RO is a resistance controlled by the current flowing through the light source. In the dark state, the resistance typically exceeds a few MOhm; when illuminated, it decreases as the inverse of the light intensity. In contrast to the photodiode and phototransistor, the photoresistor can operate in both the AC and DC circuits and have a voltage of several hundred volts across it. The harmonic distortions of the output current by the RO are typically within 0.1% at voltages below 0.5 V.RO is the first and the slowest opto-isolator: its switching time exceeds 1 ms, and for the lamp-based models can reach hundreds of milliseconds. Parasitic capacitance limits the frequency range of the photoresistor by ultrasonic frequencies. Cadmium-based photoresistors exhibit a ""memory effect"": their resistance depends on the illumination history; it also drifts during the illumination and stabilizes within hours, or even weeks for high-sensitivity models. Heating induces irreversible degradation of ROs, whereas cooling to below −25 °C dramatically increases the response time. Therefore, ROs were mostly replaced in the 1970s by the faster and more stable photodiodes and photoresistors. ROs are still used in some sound equipment, guitar amplifiers and analog synthesizers owing to their good electrical isolation, low signal distortion and ease of circuit design.