NorMax® - Norelco Oy
... Fused load-break switch cubicle MaxFu Fused load-break switch cubicle is used as transformer feeder or protection. The cubicle has SF6-gas insulated load switch and separate earthing switch with control device. The main busbar is air-insulated. The fused load-break switch is equipped with two earthi ...
... Fused load-break switch cubicle MaxFu Fused load-break switch cubicle is used as transformer feeder or protection. The cubicle has SF6-gas insulated load switch and separate earthing switch with control device. The main busbar is air-insulated. The fused load-break switch is equipped with two earthi ...
MAX5380/MAX5381/MAX5382 Low-Cost, Low-Power, 8-Bit DACs with 2-Wire Serial Interface in SOT23 General Description
... The two bus lines (SDA and SCL) must be high when the bus is not in use. The MAX5380/MAX5381/ MAX5382 are receive-only devices (slaves) and must be controlled by a bus master device. Figure 4 shows a typical application where up to four devices can be connected to the bus, provided they have differe ...
... The two bus lines (SDA and SCL) must be high when the bus is not in use. The MAX5380/MAX5381/ MAX5382 are receive-only devices (slaves) and must be controlled by a bus master device. Figure 4 shows a typical application where up to four devices can be connected to the bus, provided they have differe ...
P84155
... Multitone Strobe Appliances can be field set to produce any one of eight commonly used alarm tones. Sound output can be field set to provide either HIGH (HI) dBA or STANDARD (STD) dBA sound output level. All Multitone Strobe models are designed for use with either filtered DC or unfiltered full-wave ...
... Multitone Strobe Appliances can be field set to produce any one of eight commonly used alarm tones. Sound output can be field set to provide either HIGH (HI) dBA or STANDARD (STD) dBA sound output level. All Multitone Strobe models are designed for use with either filtered DC or unfiltered full-wave ...
SE-325 Manual
... conductor is unlikely, a minimal loss of protection will result if it does not pass through the ground-fault-CT window. CAUTION: Voltage at terminal N rises to line-to-neutral voltage when a ground fault occurs. The same clearances are required for sensing resistors as for NGR’s. NOTE: The neutral-t ...
... conductor is unlikely, a minimal loss of protection will result if it does not pass through the ground-fault-CT window. CAUTION: Voltage at terminal N rises to line-to-neutral voltage when a ground fault occurs. The same clearances are required for sensing resistors as for NGR’s. NOTE: The neutral-t ...
MAX5250 Low-Power, Quad, 10-Bit Voltage-Output DAC with Serial Interface __________________General Description
... reference inputs are driven from the same source, the effective minimum impedance is 5kΩ. A voltage reference with a load regulation of 6ppm/mA, such as the MAX873, would typically deviate by 0.006LSB (0.015LSB worst case) when driving both MAX5250 reference inputs simultaneously at 2.5V. Driving th ...
... reference inputs are driven from the same source, the effective minimum impedance is 5kΩ. A voltage reference with a load regulation of 6ppm/mA, such as the MAX873, would typically deviate by 0.006LSB (0.015LSB worst case) when driving both MAX5250 reference inputs simultaneously at 2.5V. Driving th ...
P84870
... Multitone Strobe Appliances can be field set to produce any one of eight commonly used alarm tones. Sound output can be field set to provide either HIGH (HI) dBA or STANDARD (STD) dBA sound output level. All Multitone Strobe models are designed for use with either filtered DC or unfiltered full-wave ...
... Multitone Strobe Appliances can be field set to produce any one of eight commonly used alarm tones. Sound output can be field set to provide either HIGH (HI) dBA or STANDARD (STD) dBA sound output level. All Multitone Strobe models are designed for use with either filtered DC or unfiltered full-wave ...
L12 datasheet - Trossen Robotics
... A 1.0 ms pulse commands the controller to fully retract the actuator, and a 2.0 ms pulse signals full extension. If the motion of the actuator, or of other servos in your system, seems erratic, place a 1–4Ω resistor in series with the actuator’s red V+ leadwire. PWM Mode: This mode allows control of ...
... A 1.0 ms pulse commands the controller to fully retract the actuator, and a 2.0 ms pulse signals full extension. If the motion of the actuator, or of other servos in your system, seems erratic, place a 1–4Ω resistor in series with the actuator’s red V+ leadwire. PWM Mode: This mode allows control of ...
MAX5251 +3V, Quad, 10-Bit Voltage-Output DAC with Serial Interface __________________General Description
... guaranteed minimum input impedance. When the two reference inputs are driven from the same source, the effective minimum impedance is 5kΩ. Driving the REFAB and REFCD pins separately improves reference accuracy. In shutdown mode, the MAX5251’s REFAB and REFCD inputs enter a high-impedance state with ...
... guaranteed minimum input impedance. When the two reference inputs are driven from the same source, the effective minimum impedance is 5kΩ. Driving the REFAB and REFCD pins separately improves reference accuracy. In shutdown mode, the MAX5251’s REFAB and REFCD inputs enter a high-impedance state with ...
BD00IC0MEFJ-LB
... It is recommended that a capacitor is placed nearby pin between Input pin and GND, output pin and GND. A capacitor, between input pin and GND, is valid when the power supply impedance is high or drawing is long. Also as for a capacitor, between output pin and GND, the greater the capacity, more sust ...
... It is recommended that a capacitor is placed nearby pin between Input pin and GND, output pin and GND. A capacitor, between input pin and GND, is valid when the power supply impedance is high or drawing is long. Also as for a capacitor, between output pin and GND, the greater the capacity, more sust ...
MAX1606 28V Internal Switch LCD Bias Supply with True Shutdown General Description
... The MAX1606 allows a selectable inductor current limit of 125mA, 250mA, or 500mA (Figure 2). This allows flexibility in designing for higher current applications or for smaller, compact designs. The lower current limit allows the use of a physically smaller inductor in spacesensitive, low-power appl ...
... The MAX1606 allows a selectable inductor current limit of 125mA, 250mA, or 500mA (Figure 2). This allows flexibility in designing for higher current applications or for smaller, compact designs. The lower current limit allows the use of a physically smaller inductor in spacesensitive, low-power appl ...
e-Book POE - E
... usually used in physics. This allows use of the symbol i to represent current. Impedance, Z, is the generalized word for resistance, measured in ohms, but allowed to be complex to include the contribution of a reactive (imaginary) component. Z relates current to voltage for a particular circuit elem ...
... usually used in physics. This allows use of the symbol i to represent current. Impedance, Z, is the generalized word for resistance, measured in ohms, but allowed to be complex to include the contribution of a reactive (imaginary) component. Z relates current to voltage for a particular circuit elem ...
ADC音频放大器系列SSM2302 数据手册DataSheet 下载
... including noise caused by GSM transmission bursts and RF rectification. PSRR is typically 63 dB at 217 Hz. ...
... including noise caused by GSM transmission bursts and RF rectification. PSRR is typically 63 dB at 217 Hz. ...
FMMT6520 Features and Benefits Mechanical Data
... express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. ...
... express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. ...
Preparation of Papers in a Two-Column Format for the
... power, guaranteeing a waveform with low crest factor. ...
... power, guaranteeing a waveform with low crest factor. ...
MAX5900/MAX5901 -100V, SOT23/TDFN, Simple Swapper Hot-Swap Controllers General Description
... The MAX5900/MAX5901 are SOT23/TDFN hot-swap controllers that allow a circuit card to be safely hot-plugged into a live backplane without causing a glitch on the power-supply rail. These devices operate from -9V to -100V and provide the simplest hot-swap solution by eliminating all external component ...
... The MAX5900/MAX5901 are SOT23/TDFN hot-swap controllers that allow a circuit card to be safely hot-plugged into a live backplane without causing a glitch on the power-supply rail. These devices operate from -9V to -100V and provide the simplest hot-swap solution by eliminating all external component ...
MAX16060/MAX16061/MAX16062 1% Accurate, Quad-/Hex-/Octal-Voltage µP Supervisors General Description
... voltage up to 5.5V. Other features offered include a manual reset input, a tolerance pin for selecting 5% or 10% input thresholds, and a margin enable function for deasserting the outputs during margin testing. An additional feature is a watchdog timer that asserts RESET when the watchdog timeout pe ...
... voltage up to 5.5V. Other features offered include a manual reset input, a tolerance pin for selecting 5% or 10% input thresholds, and a margin enable function for deasserting the outputs during margin testing. An additional feature is a watchdog timer that asserts RESET when the watchdog timeout pe ...
Reference Voltage (VREF )
... INSTALL a new ETBTPS. REFER to the Workshop Manual Section 303-04, Fu Charging and Controls or Section 303-14, Electronic Engine Controls. Clear the PCM DTCs. REPEAT the self-test. ...
... INSTALL a new ETBTPS. REFER to the Workshop Manual Section 303-04, Fu Charging and Controls or Section 303-14, Electronic Engine Controls. Clear the PCM DTCs. REPEAT the self-test. ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.