Analog Interfacing Networks for DAC348x and
... Typically, in order to interface the DAC348x with some of the popular modulators such as TI's TRF370315 or TRF370417, series resistor R3 must be in the 1-kΩ range. This series resistance creates higher loss that limits the output power. R3 can also interact with the input capacitance of the modulato ...
... Typically, in order to interface the DAC348x with some of the popular modulators such as TI's TRF370315 or TRF370417, series resistor R3 must be in the 1-kΩ range. This series resistance creates higher loss that limits the output power. R3 can also interact with the input capacitance of the modulato ...
UM0355
... Option bytes are only accessed using In-Circuit Programming or an ST programming tool such as an EPB. In this case, the option bytes are configured as described below. – Watchdog is configured to be enabled by software and to allow the MCU to enter Halt Mode (no reset on Halt). – The LVD threshold i ...
... Option bytes are only accessed using In-Circuit Programming or an ST programming tool such as an EPB. In this case, the option bytes are configured as described below. – Watchdog is configured to be enabled by software and to allow the MCU to enter Halt Mode (no reset on Halt). – The LVD threshold i ...
S9004C
... All inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel. When synchronization is required, the appliances shall be compatible with the Wheelock Series DSM Sync Module(s). The strobes shall not drift out of synchroniza ...
... All inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel. When synchronization is required, the appliances shall be compatible with the Wheelock Series DSM Sync Module(s). The strobes shall not drift out of synchroniza ...
Implementing a receiver in a fast data transfer system - A feasibility study
... Fig. 4.21 Input and output signals of the dual-Op-amp IA..........................................56 Fig. 4.22 The input delay between the inputs of Op2 in the dual-Op-amp IA .............57 Fig. 4.23 The CMRR versus the frequency of the dual-Op-amp IA............................57 Fig. 4.24 The dyn ...
... Fig. 4.21 Input and output signals of the dual-Op-amp IA..........................................56 Fig. 4.22 The input delay between the inputs of Op2 in the dual-Op-amp IA .............57 Fig. 4.23 The CMRR versus the frequency of the dual-Op-amp IA............................57 Fig. 4.24 The dyn ...
ACS716: 120 kHz Bandwidth, High-Voltage Isolation Current Sensor
... element is situated in extremely close proximity to the current to be measured. High-level immunity to current conductor dV/dt and stray electric fields, offered by Allegro proprietary integrated shield technology, results in low ripple on the output and low offset drift in high-side, high-voltage a ...
... element is situated in extremely close proximity to the current to be measured. High-level immunity to current conductor dV/dt and stray electric fields, offered by Allegro proprietary integrated shield technology, results in low ripple on the output and low offset drift in high-side, high-voltage a ...
LTC5569 - 300MHz to 4GHz 3.3V Dual Active Downconverting Mixer.
... RFA/RFB (Pin 1/Pin 4): Single-Ended RF Inputs for the A and B Mixers, Respectively. These pins are internally connected to the primary winding of the integrated RF transformers, which have low DC resistance to ground. Series DC-blocking capacitors must be used if the RF sources have DC voltage prese ...
... RFA/RFB (Pin 1/Pin 4): Single-Ended RF Inputs for the A and B Mixers, Respectively. These pins are internally connected to the primary winding of the integrated RF transformers, which have low DC resistance to ground. Series DC-blocking capacitors must be used if the RF sources have DC voltage prese ...
Interconnection Guideline
... with aggregate capacity up to 100 kW for three phase generators and 30 kW for single-phase generators. Based on this size limitation, it is anticipated that the generation systems will be interconnected with radial Distribution Systems at typical primary voltages (rated less than 26,400 V phase to p ...
... with aggregate capacity up to 100 kW for three phase generators and 30 kW for single-phase generators. Based on this size limitation, it is anticipated that the generation systems will be interconnected with radial Distribution Systems at typical primary voltages (rated less than 26,400 V phase to p ...
Q1 - Texas Instruments
... differential receiver, which operate from a single power supply. In the 'HVD1782, the driver differential outputs and the receiver differential inputs are connected internally to form a bus port suitable for half-duplex (two-wire bus) communication. This port features a wide common-mode voltage rang ...
... differential receiver, which operate from a single power supply. In the 'HVD1782, the driver differential outputs and the receiver differential inputs are connected internally to form a bus port suitable for half-duplex (two-wire bus) communication. This port features a wide common-mode voltage rang ...
D5V0P4B5LP08 Features Mechanical Data
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
MAX5550 Dual, 10-Bit, Programmable, 30mA High-Output-Current DAC General Description
... for PIN diode biasing applications. Outputs can also be paralleled for high-current applications (up to 60mA typ). Operating from a single +2.7V to +5.25V supply, the MAX5550 typically consumes 1.5mA per DAC in normal operation and less than 1µA (max) in shutdown mode. The MAX5550 also features low ...
... for PIN diode biasing applications. Outputs can also be paralleled for high-current applications (up to 60mA typ). Operating from a single +2.7V to +5.25V supply, the MAX5550 typically consumes 1.5mA per DAC in normal operation and less than 1µA (max) in shutdown mode. The MAX5550 also features low ...
YORK SSS Style B Liquid Cooled Solid State Starter Operation
... equipment and/or environmental pollution if proper care is not taken or instructions and are not followed. ...
... equipment and/or environmental pollution if proper care is not taken or instructions and are not followed. ...
AAT3686 数据资料DataSheet下载
... USBH and USBL modes; however, the user may program either mode to any level up to 500mA. The USBH/L mode has automatic Charge Reduction Loop control to allow users to charge the battery with limited available current from a USB port, while maintaining the regulated port voltage. This system assures ...
... USBH and USBL modes; however, the user may program either mode to any level up to 500mA. The USBH/L mode has automatic Charge Reduction Loop control to allow users to charge the battery with limited available current from a USB port, while maintaining the regulated port voltage. This system assures ...
8-Bit, 100 MSPS, CommsDAC(TM
... The THS5641A is an 8-bit resolution digital-to-analog converter (DAC) optimized for video applications and digital data transmission in wired and wireless communication systems. The 8-bit DAC is a member of the CommsDAC series of high-speed, low-power CMOS digital-to-analog converters. The CommsDAC ...
... The THS5641A is an 8-bit resolution digital-to-analog converter (DAC) optimized for video applications and digital data transmission in wired and wireless communication systems. The 8-bit DAC is a member of the CommsDAC series of high-speed, low-power CMOS digital-to-analog converters. The CommsDAC ...
Design of Single-Switch Inverters for Variable Resistance / Load
... power is controlled by phase-shifting the switching times of multiple inverters (i.e., phase-shift control of two or more inverters). When designed with an appropriate lossless power combiner – such as a Chireix combiner or multi-way lossless combiner – the real component of the effective load imped ...
... power is controlled by phase-shifting the switching times of multiple inverters (i.e., phase-shift control of two or more inverters). When designed with an appropriate lossless power combiner – such as a Chireix combiner or multi-way lossless combiner – the real component of the effective load imped ...
Research on High Efficiency Non-Isolated Push-Pull
... triangular, as shown in Fig.1(c). From the small-signal mathematical model, it can be seen that they are fourth-order because they contain four storage elements. These converters are hard to design due to the high order feature and the right half phase zero (RHPZ). Another improvement method is to i ...
... triangular, as shown in Fig.1(c). From the small-signal mathematical model, it can be seen that they are fourth-order because they contain four storage elements. These converters are hard to design due to the high order feature and the right half phase zero (RHPZ). Another improvement method is to i ...
Phys241ManualUnit4
... Charge an electrolytic capacitor without resistance in the correct direction using the 9-Volt battery (this happens quickly since there is very little resistance). Then switch to discharge the capacitor through a ~10 [k resistor (if the resistance is too small, the capacitor will discharge too rap ...
... Charge an electrolytic capacitor without resistance in the correct direction using the 9-Volt battery (this happens quickly since there is very little resistance). Then switch to discharge the capacitor through a ~10 [k resistor (if the resistance is too small, the capacitor will discharge too rap ...
H7GP/H7HP Total Counter/Time Counter
... Short-circuit (ON) impedance: 1 KΩ max. Short-circuit (ON) residual voltage: 2 VDC max. Open (OFF) impedance: 100 kΩ min. Voltage input (PNP transistor input) Short-circuit (ON) impedance: 1 KΩ max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Open (OFF) impedance: 100 kΩ min. ...
... Short-circuit (ON) impedance: 1 KΩ max. Short-circuit (ON) residual voltage: 2 VDC max. Open (OFF) impedance: 100 kΩ min. Voltage input (PNP transistor input) Short-circuit (ON) impedance: 1 KΩ max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Open (OFF) impedance: 100 kΩ min. ...
the lighter note - AudioRoundTable.com
... Set a DMM to read 20V DC. Connect one lead to the GNDGND terminal and the other to the anode of the diode at the outside of the board just by the target LM317 – see right and Step 2. Use the Mount this diode as shown to trimmers to set the voltage of the regulators to about 13 volts. provide a conve ...
... Set a DMM to read 20V DC. Connect one lead to the GNDGND terminal and the other to the anode of the diode at the outside of the board just by the target LM317 – see right and Step 2. Use the Mount this diode as shown to trimmers to set the voltage of the regulators to about 13 volts. provide a conve ...
Voltage regulator
A voltage regulator is designed to automatically maintain a constant voltage level. A voltage regulator may be a simple ""feed-forward"" design or may include negative feedback control loops. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.Electronic voltage regulators are found in devices such as computer power supplies where they stabilize the DC voltages used by the processor and other elements. In automobile alternators and central power station generator plants, voltage regulators control the output of the plant. In an electric power distribution system, voltage regulators may be installed at a substation or along distribution lines so that all customers receive steady voltage independent of how much power is drawn from the line.