Refractory Neuron Circuits
... continuously varying mean firing rate of the neuron is presumed to carry the information about the neuron's time-varying state of excitation [1]. This useful simplification allows the neuron's state to be represented as a time-varying continuous-amplitude quantity. However, spike timing is known to ...
... continuously varying mean firing rate of the neuron is presumed to carry the information about the neuron's time-varying state of excitation [1]. This useful simplification allows the neuron's state to be represented as a time-varying continuous-amplitude quantity. However, spike timing is known to ...
3021/3023 BuckPuck - LUXdrive LED Drivers
... Where the ability to adjust the output current to an intermediate value is required, all output current ratings are available with an on-board potentiometer. This permits the output current to be varied from approximately 40% to 110% of the rated value. When measuring the output is required to deter ...
... Where the ability to adjust the output current to an intermediate value is required, all output current ratings are available with an on-board potentiometer. This permits the output current to be varied from approximately 40% to 110% of the rated value. When measuring the output is required to deter ...
troubleshooting tables
... Connect load to batteries and operate it long enough to bring down battery voltage Adjust high voltage disconnect on charge ...
... Connect load to batteries and operate it long enough to bring down battery voltage Adjust high voltage disconnect on charge ...
R302 Receiver, made before Oct 2007
... which of the lower value switch sections to turn on to raise the frequency to the higher channels. E.g., to change from 146.790 to 146.820, note that you need to turn on switch sections to add 30 kHz to the setting for ...
... which of the lower value switch sections to turn on to raise the frequency to the higher channels. E.g., to change from 146.790 to 146.820, note that you need to turn on switch sections to add 30 kHz to the setting for ...
Digital Trip Coil Supervision Relay
... Both resistance measuring unit outputs are the inputs of an equality comparator (this is a comparator that produces output when both inputs are high or low, i.e. equal). In the example mentioned, one measuring unit gives a HIGHER resistance than the setting whereas the other gives a LOWER resistance ...
... Both resistance measuring unit outputs are the inputs of an equality comparator (this is a comparator that produces output when both inputs are high or low, i.e. equal). In the example mentioned, one measuring unit gives a HIGHER resistance than the setting whereas the other gives a LOWER resistance ...
Technical information for micro switches
... 5. Contact resistance given in performance specifications is measured with a voltage drop method using 6 to 8 V DC, 1 A (except for low-level load type). Contact resistance across COM and NC terminals is measured in the open position, while contact resistance across COM and NO terminals is measured ...
... 5. Contact resistance given in performance specifications is measured with a voltage drop method using 6 to 8 V DC, 1 A (except for low-level load type). Contact resistance across COM and NC terminals is measured in the open position, while contact resistance across COM and NO terminals is measured ...
Installation Instruction Sheet for Vision Site Small LED
... • RISK OF PERSONAL INJURY – Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components to their recommended torque values. • RISK OF PERSONAL INJURY – Do not lift pole into place by securing lifting device to lighting fixture or mounting arm. • DO NOT mou ...
... • RISK OF PERSONAL INJURY – Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components to their recommended torque values. • RISK OF PERSONAL INJURY – Do not lift pole into place by securing lifting device to lighting fixture or mounting arm. • DO NOT mou ...
CL -CU series Compact Time Delay Relay
... Res. Adj. Types: ± 10% at high end of timing range; min. specified, or less, at low end. Repeatability (for AC units add ±1 cycle 60 Hz.): ± 3%. Release Time: 150 ms, typ.; 225 ms, max. Recycle Time: 150 ms, typ.; 225 ms, max. Note: On CU types the switching contact may momentarily transfer if the t ...
... Res. Adj. Types: ± 10% at high end of timing range; min. specified, or less, at low end. Repeatability (for AC units add ±1 cycle 60 Hz.): ± 3%. Release Time: 150 ms, typ.; 225 ms, max. Recycle Time: 150 ms, typ.; 225 ms, max. Note: On CU types the switching contact may momentarily transfer if the t ...
LT1571
... drops to typical 150µA. SELECT (LT1571-2, LT1571-5): This pin is used to select the preset battery voltage. For the LT1571-2, leave this pin open for 8.2V and ground it for 8.4V. For the LT1571-5, leave this pin open for 4.1V and ground it for 4.2V. For other battery voltages, use the adjustable LT1 ...
... drops to typical 150µA. SELECT (LT1571-2, LT1571-5): This pin is used to select the preset battery voltage. For the LT1571-2, leave this pin open for 8.2V and ground it for 8.4V. For the LT1571-5, leave this pin open for 4.1V and ground it for 4.2V. For other battery voltages, use the adjustable LT1 ...
reduction ratio
... Let’s say your power supply can produce no more than 11A output at 36V, (like the AmpFlow S-400-36). You want to use the AmpFlow E30-150 to operate a pump that is rated at 1/3 horsepower (250W), at 1800 RPM. At 36V, this motor will produce 250W of output at 8200 RPM with waste heat of about 80W. But ...
... Let’s say your power supply can produce no more than 11A output at 36V, (like the AmpFlow S-400-36). You want to use the AmpFlow E30-150 to operate a pump that is rated at 1/3 horsepower (250W), at 1800 RPM. At 36V, this motor will produce 250W of output at 8200 RPM with waste heat of about 80W. But ...
here - Cleverscope
... The PA-677 current probe uses a single square 9 V battery. This machine is a high power product. Please use the specified alkaline battery. As the battery in the PA-677 current probe is drained, significant gain errors may occur. The green LED will continue to light until a low battery voltage of 6. ...
... The PA-677 current probe uses a single square 9 V battery. This machine is a high power product. Please use the specified alkaline battery. As the battery in the PA-677 current probe is drained, significant gain errors may occur. The green LED will continue to light until a low battery voltage of 6. ...
n60_spec - GE Grid Solutions
... Out-of-step tripping and power swing blocking measures the positive sequence apparent impedance and traces its locus with respect to either two or three operating characteristics boundaries. This element also incorporates an adaptive disturbances detector. This function is capable of detecting faste ...
... Out-of-step tripping and power swing blocking measures the positive sequence apparent impedance and traces its locus with respect to either two or three operating characteristics boundaries. This element also incorporates an adaptive disturbances detector. This function is capable of detecting faste ...
Super-E - Clark Transmission
... each motor with action: – Replace immediately with Super-E motor – Replace on failure with Super-E motor – Replace on failure with Standard-E motor – Rewind on failure • Reduce downtime - use replacement as an opportunity to upgrade motor enclosure and level of protection (replace with Severe Duty, ...
... each motor with action: – Replace immediately with Super-E motor – Replace on failure with Super-E motor – Replace on failure with Standard-E motor – Rewind on failure • Reduce downtime - use replacement as an opportunity to upgrade motor enclosure and level of protection (replace with Severe Duty, ...
E–H Mode Transition of an Inductively Coupled Plasma Torch
... Introduction The so-called thermal plasma torches can be divided into two main families, arc torches and inductively coupled torches. Whilst this latter family is generally applied to low power applications such as chemical analysis, due to its better homogeneity, inductively coupled plasma torches ...
... Introduction The so-called thermal plasma torches can be divided into two main families, arc torches and inductively coupled torches. Whilst this latter family is generally applied to low power applications such as chemical analysis, due to its better homogeneity, inductively coupled plasma torches ...
PFC MegaPAC MI™ Family
... This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assum ...
... This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assum ...
Generator Transfer Device
... Generator (or central inverter) supplied egress lighting shall be provided by using a standard fluorescent or LED fixture equipped with a Philips Bodine GTD generator transfer device.The device shall be capable of bypassing the wall switch when the auxiliary generator (or central inverter) powers li ...
... Generator (or central inverter) supplied egress lighting shall be provided by using a standard fluorescent or LED fixture equipped with a Philips Bodine GTD generator transfer device.The device shall be capable of bypassing the wall switch when the auxiliary generator (or central inverter) powers li ...