AP65402 - Diodes Incorporated
... EA output voltage, the RS Flip-Flop is reset and HS MOSFET is turned off. For one whole cycle, if the sum of the current sense amplifier output and the slope compensation signal does not exceed the EA output, then the falling edge of the oscillator clock resets the Flip-Flop. The output of the error ...
... EA output voltage, the RS Flip-Flop is reset and HS MOSFET is turned off. For one whole cycle, if the sum of the current sense amplifier output and the slope compensation signal does not exceed the EA output, then the falling edge of the oscillator clock resets the Flip-Flop. The output of the error ...
electrical equipment definitions
... A non-hostile operating environment refers to a workplace where electrical equipment is used in a working environment that is dry, clean, well organised and free of operating conditions that are likely to result in damage to the item of electrical equipment or flexible supply cord. For example, an o ...
... A non-hostile operating environment refers to a workplace where electrical equipment is used in a working environment that is dry, clean, well organised and free of operating conditions that are likely to result in damage to the item of electrical equipment or flexible supply cord. For example, an o ...
Week 10 - Air Washington
... In electrical power distribution, a busbar is a strip or bar that conducts electricity within an electrical apparatus. Its main purpose is to conduct electricity, not to function as a structural member. A distribution point in an aircraft electrical system to which the battery and the generator(s) a ...
... In electrical power distribution, a busbar is a strip or bar that conducts electricity within an electrical apparatus. Its main purpose is to conduct electricity, not to function as a structural member. A distribution point in an aircraft electrical system to which the battery and the generator(s) a ...
MAX4880 Overvoltage-Protection Controller with Internal Disconnect Switch General Description
... of the package. This pad is internally connected to GND. For the best thermal conductivity and higher power dissipation, solder the exposed pad to the ground plane. Do not use the ground-connected pad as the only electrical ground connection or ground return. Use GND (pin 6) as the primary electrica ...
... of the package. This pad is internally connected to GND. For the best thermal conductivity and higher power dissipation, solder the exposed pad to the ground plane. Do not use the ground-connected pad as the only electrical ground connection or ground return. Use GND (pin 6) as the primary electrica ...
Single and Three Phase Overhead Transformer
... Partners' poletype clistrihution transformers are specifically designed to serve residential overhead distribution loads. The y arc also suitable for light commercial loads, industrial lighting, and diversified power applications. Power Partners provides a complete line of overhead transformers to m ...
... Partners' poletype clistrihution transformers are specifically designed to serve residential overhead distribution loads. The y arc also suitable for light commercial loads, industrial lighting, and diversified power applications. Power Partners provides a complete line of overhead transformers to m ...
Dual-Color Type Chip LEDs with reflector
... third party's intellectual property rights or other proprietary rights, and further, assumes no liability of whatsoever nature in the event of any such infringement, or arising from or connected with or related to the use of such devices. Upon the sale of any such devices, other than for buyer's rig ...
... third party's intellectual property rights or other proprietary rights, and further, assumes no liability of whatsoever nature in the event of any such infringement, or arising from or connected with or related to the use of such devices. Upon the sale of any such devices, other than for buyer's rig ...
Chapter - 1 - facts controllers
... control of power flow during and following system faults. This objective of course does not mean to say that the lines would normally be operated at their thermal limit loading (the transmission losses would be unacceptable), but this option would be available, if needed, to handle severe system con ...
... control of power flow during and following system faults. This objective of course does not mean to say that the lines would normally be operated at their thermal limit loading (the transmission losses would be unacceptable), but this option would be available, if needed, to handle severe system con ...
Qualified Electrical Worker Test
... or equipment are reenergized, even temporarily. D. (b) (2) (v) (A) A qualified person shall _____________________________, as necessary, to verify that all tools, electrical jumpers, shorts, grounds, and other such devices have been removed, so that the circuits and equipment can be safely energized ...
... or equipment are reenergized, even temporarily. D. (b) (2) (v) (A) A qualified person shall _____________________________, as necessary, to verify that all tools, electrical jumpers, shorts, grounds, and other such devices have been removed, so that the circuits and equipment can be safely energized ...
pub3241bvariablefrequencydrives
... energy reduction – if slowing the motor down for the purpose of flow or pressure regulation will have a benefit. Motordriven equipment often is operated at reduced loads or restricted flows, and the opportunity to decrease energy consumption becomes much greater compared to equipment operating at ma ...
... energy reduction – if slowing the motor down for the purpose of flow or pressure regulation will have a benefit. Motordriven equipment often is operated at reduced loads or restricted flows, and the opportunity to decrease energy consumption becomes much greater compared to equipment operating at ma ...
Bourns® Chip Resistors
... Resistance Tolerance • F = ±1 %.................Use with “X” TCR code • J = ±5 % .................Use with “W” TCR code for values from 1 ohm through 1 megohm Use with “X” TCR code for values from 0.047 ohm through 0.91 ohm Use with “/” TCR code for 0 ohm (Jumper) TCR (PPM/°C - See Electrical Charac ...
... Resistance Tolerance • F = ±1 %.................Use with “X” TCR code • J = ±5 % .................Use with “W” TCR code for values from 1 ohm through 1 megohm Use with “X” TCR code for values from 0.047 ohm through 0.91 ohm Use with “/” TCR code for 0 ohm (Jumper) TCR (PPM/°C - See Electrical Charac ...
SIRComm® MiniSIR2® 115.2kbps IrDA®1.0 Transceiver Module
... drive current can be reduced with an expected corresponding reduction in link operational distance per the following equation: ...
... drive current can be reduced with an expected corresponding reduction in link operational distance per the following equation: ...
Power semiconductor devices The difference between ideal switch
... SCR can be used to control lamps, motors, or heaters etc. However, one of the problems of using a SCR for controlling such circuits is that like a diode, the “SCR” is a unidirectional device, meaning that it passes current in one direction only, from Anode to Cathode. Circuits like shown below can b ...
... SCR can be used to control lamps, motors, or heaters etc. However, one of the problems of using a SCR for controlling such circuits is that like a diode, the “SCR” is a unidirectional device, meaning that it passes current in one direction only, from Anode to Cathode. Circuits like shown below can b ...
Complete Paper
... generation. The WECSs are interconnected to diesel generation-based grid for the enhancement of capacity and fuel saving. The system also comprises STATCOM for reactive power support during steady-state and transient conditions. A mathematical model of the system has been derived for investigating t ...
... generation. The WECSs are interconnected to diesel generation-based grid for the enhancement of capacity and fuel saving. The system also comprises STATCOM for reactive power support during steady-state and transient conditions. A mathematical model of the system has been derived for investigating t ...
LR9641 DESCRIPTION FEATURES
... switching regulator, capable of delivering up to 0.7A of output current. With a fixed switching frequency of 660KHz, this current mode PWM controlled converter allows the use of small external components, such as ceramic input and output caps, as well as small inductors.LR9641 also employs a proprie ...
... switching regulator, capable of delivering up to 0.7A of output current. With a fixed switching frequency of 660KHz, this current mode PWM controlled converter allows the use of small external components, such as ceramic input and output caps, as well as small inductors.LR9641 also employs a proprie ...
AC Circuits
... The time behavior and the state-space trajectory can be strobed once every driving cycle to reproduce a sequence of points whose values are like those of successive iterations of a map. To do this set up one function generator as a pulse generator, synchronized with the driving generator, and drivin ...
... The time behavior and the state-space trajectory can be strobed once every driving cycle to reproduce a sequence of points whose values are like those of successive iterations of a map. To do this set up one function generator as a pulse generator, synchronized with the driving generator, and drivin ...
Studies on metal–semiconductor contacts with ZrN as metal layer
... and nitrides (TiN [9], NbN [4] and WN [10, 11]) have been extensively explored for this purpose. While most of them have success to some degree, refractory metal nitrides are generally considered as very promising candidates for gate materials. Metallization in semiconductor devices is not only for ...
... and nitrides (TiN [9], NbN [4] and WN [10, 11]) have been extensively explored for this purpose. While most of them have success to some degree, refractory metal nitrides are generally considered as very promising candidates for gate materials. Metallization in semiconductor devices is not only for ...
CONSONANCE
... The selection of output capacitor (C3 in Figure 1) is primarily determined by the ESR required to minimize ripple voltage and load step transients. it is best that the input capacitor consists of the following 2 capacitors in parallel: A 10uF electrolytic capacitor for low-frequency filtering A ...
... The selection of output capacitor (C3 in Figure 1) is primarily determined by the ESR required to minimize ripple voltage and load step transients. it is best that the input capacitor consists of the following 2 capacitors in parallel: A 10uF electrolytic capacitor for low-frequency filtering A ...