servisavor instructions
... When the SERVISAVOR is installed between the meter socket and the meter up to 80 amps can be restored to the faulted leg. Have the customer turn off his main breaker. The technician disconnects the service and removes the watthour meter from its socket following his employer's safety practices. He c ...
... When the SERVISAVOR is installed between the meter socket and the meter up to 80 amps can be restored to the faulted leg. Have the customer turn off his main breaker. The technician disconnects the service and removes the watthour meter from its socket following his employer's safety practices. He c ...
LTC1799 - 1kHz to 33MHz Resistor Set SOT
... The oscillator may be programmed by any method that sources a current into the SET pin (Pin 3). The circuit in Figure 3 sets the oscillator frequency using a programmable current source and in the expression for fOSC, the resistor RSET is replaced by the ratio of 1.13V/ICONTROL. As already explained ...
... The oscillator may be programmed by any method that sources a current into the SET pin (Pin 3). The circuit in Figure 3 sets the oscillator frequency using a programmable current source and in the expression for fOSC, the resistor RSET is replaced by the ratio of 1.13V/ICONTROL. As already explained ...
LTC1069-1 - Low Power, 8th Order Progressive Elliptic, Lowpass Filter
... signal ground can affect the filter performance. For either single or dual supply operation, an analog ground plane surrounding the package is recommended. The analog ground plane should be connected to any digital ground at a single point. For dual supply operation Pin 1 should be connected to the a ...
... signal ground can affect the filter performance. For either single or dual supply operation, an analog ground plane surrounding the package is recommended. The analog ground plane should be connected to any digital ground at a single point. For dual supply operation Pin 1 should be connected to the a ...
BFR460L3
... in MWO- and ADS-format, which you can import into these circuit simulation tools very quickly and conveniently. The model already contains the package parasitics and is ready to use for DC and high frequency simulations. The terminals of the model circuit correspond to the pin configuration of the d ...
... in MWO- and ADS-format, which you can import into these circuit simulation tools very quickly and conveniently. The model already contains the package parasitics and is ready to use for DC and high frequency simulations. The terminals of the model circuit correspond to the pin configuration of the d ...
Wide VIN DC/DC Power Solutions
... Extra margin is provided for robustness of un-characterized system conditions to increase system reliability. Additionally, a single device can operate across several voltage rails to provide scalability and allow reuse of power converter designs. TI’s easy-to-use, high-density, feature-rich Wide VI ...
... Extra margin is provided for robustness of un-characterized system conditions to increase system reliability. Additionally, a single device can operate across several voltage rails to provide scalability and allow reuse of power converter designs. TI’s easy-to-use, high-density, feature-rich Wide VI ...
Some Thoughts on Regenerative Receivers
... amplifier greatly reduces radiation back into the antenna. It is not perfect, and my two commercial kit regenerative receivers make an impromptu signal generator in the ham shack when needed. An "RF" gain control can be easily introduced to reduce the strength of incoming strong signals, such as som ...
... amplifier greatly reduces radiation back into the antenna. It is not perfect, and my two commercial kit regenerative receivers make an impromptu signal generator in the ham shack when needed. An "RF" gain control can be easily introduced to reduce the strength of incoming strong signals, such as som ...
General Specification for ION7350 Power Meter : msword
... o Each event is recorded with the date and time of the event, the cause and effect of the event, and the priority of the event. o All events relating to setpoint activity, relay operation and self-diagnostics are recorded in the event log. o Time stamps have a resolution of 1 millisecond. o Time sta ...
... o Each event is recorded with the date and time of the event, the cause and effect of the event, and the priority of the event. o All events relating to setpoint activity, relay operation and self-diagnostics are recorded in the event log. o Time stamps have a resolution of 1 millisecond. o Time sta ...
FlexBar HRT Pressure Transmitter
... This instrument is built and tested according to the current EU-directives and packed in technically safe condition. In order to maintain this condition and to ensure safe operation, the user must follow the hints and warnings given in this instruction. During the installation the valid national rul ...
... This instrument is built and tested according to the current EU-directives and packed in technically safe condition. In order to maintain this condition and to ensure safe operation, the user must follow the hints and warnings given in this instruction. During the installation the valid national rul ...
Producing diamond anvil cell gaskets for ultrahigh
... increasingly utilized. Consequently, well-centered holes with diameters smaller than 100 pm need to be routinely produced in these gaskets made of exceedingly hard metals. We describe the construction of an inexpensive electric discharge machine that can drill metals with holes as small as 25 pm in ...
... increasingly utilized. Consequently, well-centered holes with diameters smaller than 100 pm need to be routinely produced in these gaskets made of exceedingly hard metals. We describe the construction of an inexpensive electric discharge machine that can drill metals with holes as small as 25 pm in ...
A fifty kilocycle per second triangular wave generator.
... output triangular wave from a Miller integrator circuit usually consists of a linear rise (or fall, as the case may be) followed by an exponential return. Although the width of the exponential return can be reduced to approximately five percent of the width of the linear portion of the waveform, it ...
... output triangular wave from a Miller integrator circuit usually consists of a linear rise (or fall, as the case may be) followed by an exponential return. Although the width of the exponential return can be reduced to approximately five percent of the width of the linear portion of the waveform, it ...
Comparative Study of Soft Switching and Hard Switching For
... when operated in a switched mode operation, the Power Switches have to cut off the load current within the turn-on and turn-off times under the hard switching conditions. Hard switching refers to the stressful switching behavior of the power electronic devices the switching trajectory of hard-switch ...
... when operated in a switched mode operation, the Power Switches have to cut off the load current within the turn-on and turn-off times under the hard switching conditions. Hard switching refers to the stressful switching behavior of the power electronic devices the switching trajectory of hard-switch ...
USER`S MANUAL DCL-420
... This meter is CUL and UL approved and conforms to IEC 61010-1 for Category II - 600V. This meter is designed to be safe under the following conditions: indoor use, altitude up to 2000m, temperature 5°C to 40°C, maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% rela ...
... This meter is CUL and UL approved and conforms to IEC 61010-1 for Category II - 600V. This meter is designed to be safe under the following conditions: indoor use, altitude up to 2000m, temperature 5°C to 40°C, maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% rela ...
X-SERIES
... 1) Read the General Notes on Page 2 if you haven’t already and determine if you have the right output jack for your instrument. A Stereo 12B type (Included) or a 152B Long Panel Jack will be required. 2) Remove the strings 3) Remove any existing Pickups and controls (remember the order and function ...
... 1) Read the General Notes on Page 2 if you haven’t already and determine if you have the right output jack for your instrument. A Stereo 12B type (Included) or a 152B Long Panel Jack will be required. 2) Remove the strings 3) Remove any existing Pickups and controls (remember the order and function ...
AD7741
... The AD7741 has a single buffered input whereas the AD7742 has four buffered inputs that may be configured as two fullydifferential inputs or three pseudo-differential inputs. Both parts include an on-chip +2.5 V bandgap reference that provides the user with the option of using this internal referenc ...
... The AD7741 has a single buffered input whereas the AD7742 has four buffered inputs that may be configured as two fullydifferential inputs or three pseudo-differential inputs. Both parts include an on-chip +2.5 V bandgap reference that provides the user with the option of using this internal referenc ...
Large Scale Superconducting Magnets for Physics Research
... All toroids 3 x 8 = 24 coils are connected in series. The energy is dumped in the 3 toroid cold masses, voltage limited to 40V. Quench detection by 3 bridges + 3 differential units per toroid so 6 fold redundancy, heaters are fired introducing 4 normal zones in every coil, ...
... All toroids 3 x 8 = 24 coils are connected in series. The energy is dumped in the 3 toroid cold masses, voltage limited to 40V. Quench detection by 3 bridges + 3 differential units per toroid so 6 fold redundancy, heaters are fired introducing 4 normal zones in every coil, ...
electric rewind installation instructions (h-8823)
... DESCRIPTION OF CIRCUIT BREAKERS The SDLM Circuit Breaker is normally used with Hannay Reels for protection of the rewind motor. This type of breaker must be manually reset by pressing firmly on the red push button if it is tripped for any reason. This insures that the problem will be corrected befor ...
... DESCRIPTION OF CIRCUIT BREAKERS The SDLM Circuit Breaker is normally used with Hannay Reels for protection of the rewind motor. This type of breaker must be manually reset by pressing firmly on the red push button if it is tripped for any reason. This insures that the problem will be corrected befor ...
Metadyne
A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or ""variator"" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is ""a cross-field direct current machine designed to utilize armature reaction"". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.