
An All-Digital A/D
... An all-digital A/D converter (ADC) for fast conversion with 4-TAD parallel construction is presented. The basic structure of the TAD is a completely digital circuit including a ring-delay-line (RDL) with delay units (DUs), along with a frequency counter, latch and encoder. The operating principles a ...
... An all-digital A/D converter (ADC) for fast conversion with 4-TAD parallel construction is presented. The basic structure of the TAD is a completely digital circuit including a ring-delay-line (RDL) with delay units (DUs), along with a frequency counter, latch and encoder. The operating principles a ...
EVALUATION AND DESIGN SUPPORT CIRCUIT FUNCTION AND BENEFITS
... final output. Achieving the required output phase matching and settling time can be a challenge, especially at low power levels. The circuit shown in Figure 1 uses the AD8475 differential funnel amplifier to perform attenuation, level shifting, and conversion to differential without the need for any ...
... final output. Achieving the required output phase matching and settling time can be a challenge, especially at low power levels. The circuit shown in Figure 1 uses the AD8475 differential funnel amplifier to perform attenuation, level shifting, and conversion to differential without the need for any ...
Evaluate: MAX4444/MAX4445 MAX4444 Evaluation Kit General Description Features
... The MAX4444 EV kit is fully assembled and tested. Follow these steps to verify board operation. Do not turn on the power supply until all connections are completed. 1) Connect a +5V power supply to the VCC pin and a -5V power supply to the VEE pin. Connect power-supply ground to the GND pads. 2) Ens ...
... The MAX4444 EV kit is fully assembled and tested. Follow these steps to verify board operation. Do not turn on the power supply until all connections are completed. 1) Connect a +5V power supply to the VCC pin and a -5V power supply to the VEE pin. Connect power-supply ground to the GND pads. 2) Ens ...
PAWS - Western Carolina University
... the spectrum analyzer and connect the oscilloscope to the generated sine wave. Verify that the frequency is 8 MHz and the output voltage is at least 1 volt peak –to-peak. If these requirements are met, continue to step 9. If the frequency is 8 MHz, but the output voltage is less than 1 volt peak –to ...
... the spectrum analyzer and connect the oscilloscope to the generated sine wave. Verify that the frequency is 8 MHz and the output voltage is at least 1 volt peak –to-peak. If these requirements are met, continue to step 9. If the frequency is 8 MHz, but the output voltage is less than 1 volt peak –to ...
16-Bit, 1 MS/s High-Speed Data Acquisition Boards
... The optional TB-100 screw terminal board connects directly to the SCSI connector using a CA-68-xx ribbon cable. The TB-100 provides access to 16 SE analog inputs, up to four analog outputs, 24 digital I/O, and all counters/timers. When using the TB-100 with the USB-2633 and USB-2637, access to the ...
... The optional TB-100 screw terminal board connects directly to the SCSI connector using a CA-68-xx ribbon cable. The TB-100 provides access to 16 SE analog inputs, up to four analog outputs, 24 digital I/O, and all counters/timers. When using the TB-100 with the USB-2633 and USB-2637, access to the ...
Nuclear Spectroscopy with the PC
... b) SET: This is a test point. You can read the “set voltage” (i.e. the voltage that the phototube is set to) with a voltmeter by putting one voltmeter probe here and the other probe in the GND test point. The calibration is such that a reading of 10 Volts corresponds to setting the phototube voltage ...
... b) SET: This is a test point. You can read the “set voltage” (i.e. the voltage that the phototube is set to) with a voltmeter by putting one voltmeter probe here and the other probe in the GND test point. The calibration is such that a reading of 10 Volts corresponds to setting the phototube voltage ...
Digital Electronics I: Logic, Flip
... analog waveforms. To display and analyze the information contained in these signals, they must be converted to digital data. Often this is done inside a commercial instrument such as an oscilloscope or a lock-in amplifier, which is then connected to a computer through a digital interface. In other c ...
... analog waveforms. To display and analyze the information contained in these signals, they must be converted to digital data. Often this is done inside a commercial instrument such as an oscilloscope or a lock-in amplifier, which is then connected to a computer through a digital interface. In other c ...
Samba™ OPLC™ OPLC Installation Guide
... For SM43: USB device programming port (Mini-B) For SM35: 1 build-in serial port:RS232 Optional: the user may install RS232/RS485 port (V100-17-RS4/V100-17-RS4X) or Ethernet (V100-17-ET2) & CANbus (V100-17-CAN) ...
... For SM43: USB device programming port (Mini-B) For SM35: 1 build-in serial port:RS232 Optional: the user may install RS232/RS485 port (V100-17-RS4/V100-17-RS4X) or Ethernet (V100-17-ET2) & CANbus (V100-17-CAN) ...
CHAPTER 7 Internal structure of operational amplifiers
... When applying common input signals, the bases of T3 and T4 are not virtually grounded, and because they are connected to high a internal resistance point of the network the input transistors will not be driven by such input signals, meaning that the CMRR of the amplifier is very high (according to t ...
... When applying common input signals, the bases of T3 and T4 are not virtually grounded, and because they are connected to high a internal resistance point of the network the input transistors will not be driven by such input signals, meaning that the CMRR of the amplifier is very high (according to t ...
100 16 Isolated
... In the pursuit of isolated high-speed waveform measurement, Yokogawa has achieved a maximum sample rate of 100 MS/s (10 ns sampling interval). The SL1000 can accurately capture high-speed and high-voltage phenomena by using the newly developed 100 MS/s 12Bit 20 MHz frequency range 1-kV* Isolation Mo ...
... In the pursuit of isolated high-speed waveform measurement, Yokogawa has achieved a maximum sample rate of 100 MS/s (10 ns sampling interval). The SL1000 can accurately capture high-speed and high-voltage phenomena by using the newly developed 100 MS/s 12Bit 20 MHz frequency range 1-kV* Isolation Mo ...
LM747.PDF
... Note 1: The maximum junction temperature of the LM747C/LM747E is 100§ C. For operating at elevated temperatures, devies in the TO-5 package must be derated based on a thermal resistance of 150§ C/W, junction to ambient, or 45§ C/W, junction to case. The thermal resistance of the dual-in-line package ...
... Note 1: The maximum junction temperature of the LM747C/LM747E is 100§ C. For operating at elevated temperatures, devies in the TO-5 package must be derated based on a thermal resistance of 150§ C/W, junction to ambient, or 45§ C/W, junction to case. The thermal resistance of the dual-in-line package ...
MAX1205 +5V Single-Supply, 1Msps, 14-Bit Self-Calibrating ADC General Description
... with digital error correction and a short self-calibration procedure that corrects for capacitor and gain mismatches and ensures 14-bit linearity at full sample rates. An on-chip track/hold (T/H) maintains superb dynamic performance up to the Nyquist frequency. The MAX1205 operates from a single +5V ...
... with digital error correction and a short self-calibration procedure that corrects for capacitor and gain mismatches and ensures 14-bit linearity at full sample rates. An on-chip track/hold (T/H) maintains superb dynamic performance up to the Nyquist frequency. The MAX1205 operates from a single +5V ...
Bds96 - Instituto de Ingeniería Eléctrica
... The input signals of the circuit are cardiac signals previously filtered and amplified. A standard test waveform representing the cardiac signal is a triangular wave with 2ms rise time and 13ms fall time, sometimes referred as "Tokyo signal" [1]. This signal was applied throughout the circuit develo ...
... The input signals of the circuit are cardiac signals previously filtered and amplified. A standard test waveform representing the cardiac signal is a triangular wave with 2ms rise time and 13ms fall time, sometimes referred as "Tokyo signal" [1]. This signal was applied throughout the circuit develo ...
Oscilloscope types

This is a subdivision of the Oscilloscope article, discussing the various types and models of oscilloscopes in greater detail.