RS232 To RS485 Converter
... The Interfacecom RS232 To RS485 Converter allows RS-232 equipment to utilize RS-485 networks, oper-ating in either point-to-point or multi-point, 2-or 4-wire. The RS232 To RS485 Converter is one of the most cost effective RS-485 solutions on the market. Use with your standard PC or Laptop to control ...
... The Interfacecom RS232 To RS485 Converter allows RS-232 equipment to utilize RS-485 networks, oper-ating in either point-to-point or multi-point, 2-or 4-wire. The RS232 To RS485 Converter is one of the most cost effective RS-485 solutions on the market. Use with your standard PC or Laptop to control ...
ADP-40 Analog Door Phone P/N 1200761L1
... A standard single-gang wet location (weather proof) electrical box (Pass & Seymour 93C6 or equivalent) can be used to surface mount the ADP-40. 1. Drill a small wire exit hole in the wall. 2. Pull the wire through and seal the hole around the wire with putty or caulking. 3. Route the wire into the w ...
... A standard single-gang wet location (weather proof) electrical box (Pass & Seymour 93C6 or equivalent) can be used to surface mount the ADP-40. 1. Drill a small wire exit hole in the wall. 2. Pull the wire through and seal the hole around the wire with putty or caulking. 3. Route the wire into the w ...
www.maretron.com 1-866-550-9100
... A Powertap Tee is connected to a network backbone just like any Tee but rather than connecting a device their purpose is to provide “bus” power. Maretron Powertap Tee uniquely provides two power inputs permitting doubled power provision for devices. ...
... A Powertap Tee is connected to a network backbone just like any Tee but rather than connecting a device their purpose is to provide “bus” power. Maretron Powertap Tee uniquely provides two power inputs permitting doubled power provision for devices. ...
Transitioning to Flame from the USB Series
... To start, the firmware version number now takes the form “FLAME-S 1.23.4“rather than “USB2000+ 1.23.4. “ This version number is how the Ocean Optics software distinguishes between Flame and USB devices. The firmware also uses a new process to update the FPGA via USB Programmer. Therefore, the Flame ...
... To start, the firmware version number now takes the form “FLAME-S 1.23.4“rather than “USB2000+ 1.23.4. “ This version number is how the Ocean Optics software distinguishes between Flame and USB devices. The firmware also uses a new process to update the FPGA via USB Programmer. Therefore, the Flame ...
DTC B1800/51 Short in Driver Side Squib Circuit DTC B1801/51
... (j) Check the DTCs (see page RS-49). OK: DTC B1800, B1801, B1802, B1803 or 51 is not output. HINT: DTCs other than DTC B1800, B1801, B1802, B1803 or 51 may be output at this time, but they are not related to this check. OK ...
... (j) Check the DTCs (see page RS-49). OK: DTC B1800, B1801, B1802, B1803 or 51 is not output. HINT: DTCs other than DTC B1800, B1801, B1802, B1803 or 51 may be output at this time, but they are not related to this check. OK ...
SIMATIC S7 S7-1200 Programmable controller
... be gold. See Appendix C, Spare Parts for order number. Note 2: Either the L1 or N (L2) terminal can be connected to a voltage source up to 240 VAC. The N terminal can be considered L2 and is not required to be grounded. No polarization is required for L1 and N (L2) terminals. Table 2 ...
... be gold. See Appendix C, Spare Parts for order number. Note 2: Either the L1 or N (L2) terminal can be connected to a voltage source up to 240 VAC. The N terminal can be considered L2 and is not required to be grounded. No polarization is required for L1 and N (L2) terminals. Table 2 ...
Compact FieldPoint Accessories Operating Instructions
... NI offers several accessories for mounting the Compact FieldPoint system on a DIN rail, in a standard 19 in. instrumentation rack, or on a panel. Refer to the cFP-20xx and cFP-BP-x User Manual for instructions on using Compact FieldPoint mounting accessories. Follow the cooling guidelines in the cFP ...
... NI offers several accessories for mounting the Compact FieldPoint system on a DIN rail, in a standard 19 in. instrumentation rack, or on a panel. Refer to the cFP-20xx and cFP-BP-x User Manual for instructions on using Compact FieldPoint mounting accessories. Follow the cooling guidelines in the cFP ...
SWR meter for 144-1296 MHz bands - Ok1tic
... The directional coupler looks simple but its construction is not so easy and straightforward. I’ll try to describe here some hints and recommendations. The only suitable transmission line for this application is the „pipe“ semirigid coaxial line. The transmission line whose outer conductor is made o ...
... The directional coupler looks simple but its construction is not so easy and straightforward. I’ll try to describe here some hints and recommendations. The only suitable transmission line for this application is the „pipe“ semirigid coaxial line. The transmission line whose outer conductor is made o ...
DSM3 Installation and Quick Start Guide for XM3
... DSM3 Series transponders utilize Simple Network Management Protocol (SNMP) and Management Information Bases (MIBs) to provide network status monitoring and diagnostics. A Web interface enables authorized personnel direct local and remote access to advanced diagnostics using a common Web browser. No ...
... DSM3 Series transponders utilize Simple Network Management Protocol (SNMP) and Management Information Bases (MIBs) to provide network status monitoring and diagnostics. A Web interface enables authorized personnel direct local and remote access to advanced diagnostics using a common Web browser. No ...
OUTLAND 1000 ROV TROUBLE SHOOTING HELP.
... female connectors need to be removed, cleaned and re-greased. However it is also possible the lights have some moisture inside them. 1) Unplug the connectors from the lights and inspect them for water or the fact they may be devoid of any silicon grease. 2) If the have grease in them and look OK the ...
... female connectors need to be removed, cleaned and re-greased. However it is also possible the lights have some moisture inside them. 1) Unplug the connectors from the lights and inspect them for water or the fact they may be devoid of any silicon grease. 2) If the have grease in them and look OK the ...
EHS Standard HV Modules 16 Channels with Common
... voltage in any channel is only present if the safety loop is closed and an external current in a range of 5 to 20 mA of any polarity is driven through the loop. (For modules with a REDEL-connector the other SL input must be closed.) If the safety loop is opened during the operation the output voltag ...
... voltage in any channel is only present if the safety loop is closed and an external current in a range of 5 to 20 mA of any polarity is driven through the loop. (For modules with a REDEL-connector the other SL input must be closed.) If the safety loop is opened during the operation the output voltag ...
WABCO D-Basic Hydraulic Antilock Braking System
... open. If resistance is right at Resistance is greater than 680 680 Ohms then the retarder relay is open. ohms If greater than 680 Ohms the retarder relay coil and its resistor are both open, or circuit 376R is open, or retarder relay coil ground circuit is open. repair as necessary. * ...
... open. If resistance is right at Resistance is greater than 680 680 Ohms then the retarder relay is open. ohms If greater than 680 Ohms the retarder relay coil and its resistor are both open, or circuit 376R is open, or retarder relay coil ground circuit is open. repair as necessary. * ...
UF-PNPI HV system. Stage 2 proposal - Indico
... To have ~10% of spare RDB and MB plus 10% of spare regulators we need to produce in total: - 56 RDB + 400 spare regulators - 8 MB + 16 spare regulators ...
... To have ~10% of spare RDB and MB plus 10% of spare regulators we need to produce in total: - 56 RDB + 400 spare regulators - 8 MB + 16 spare regulators ...
Board User`s Manual White LED Card
... AUTOSAR development partnership. Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigation Ltd. EMV™ of EMVCo, LLC (Visa Holdings Inc.). EPCOS™ of Epcos AG. FLEXGO™ of Microsoft Corporation. FlexRay™ is licensed by FlexRay Consortium. HYPERTERMINAL™ of Hilgra ...
... AUTOSAR development partnership. Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigation Ltd. EMV™ of EMVCo, LLC (Visa Holdings Inc.). EPCOS™ of Epcos AG. FLEXGO™ of Microsoft Corporation. FlexRay™ is licensed by FlexRay Consortium. HYPERTERMINAL™ of Hilgra ...
Agilent Investigating Microvia Technology for 10 Gbps
... Designing a surface mount board to backplane connector has numerous requirements. First, the interface must withstand the mechanical conditions faced by standard board applications and be very rugged. Secondly, the connector must be able to transmit data at speeds exceeding 10 Gbps. Recent designs o ...
... Designing a surface mount board to backplane connector has numerous requirements. First, the interface must withstand the mechanical conditions faced by standard board applications and be very rugged. Secondly, the connector must be able to transmit data at speeds exceeding 10 Gbps. Recent designs o ...
X-19s User Manual
... error. This is especially problematic where the X-19s is used to measure multiple 4-20mA sensors. When connecting more than one 4-20ma sensor consider using a “star” or single point ground topology. If the output current from one sensor changes or affects the measurements of other sensors (crosstalk ...
... error. This is especially problematic where the X-19s is used to measure multiple 4-20mA sensors. When connecting more than one 4-20ma sensor consider using a “star” or single point ground topology. If the output current from one sensor changes or affects the measurements of other sensors (crosstalk ...
Assembly Instructions
... There is one 5mm infra-red LED. It must be inserted with the longer wire in the hole with the “+” sign next to it. Insert it about 8-10mm above the PCB so it can be bent at 90 degrees, in line with the PCB. ...
... There is one 5mm infra-red LED. It must be inserted with the longer wire in the hole with the “+” sign next to it. Insert it about 8-10mm above the PCB so it can be bent at 90 degrees, in line with the PCB. ...
Condition/Concern: Recommendation/Instructions
... plugs may also go open. This electrical "noise" may be induced by jump starting, disconnecting the batteries with the ignition in the ON position, or a battery charger being used during a module reprogramming event. 3. If the glowplug DTCs have set on a very low mileage vehicle (below 1000 miles) th ...
... plugs may also go open. This electrical "noise" may be induced by jump starting, disconnecting the batteries with the ignition in the ON position, or a battery charger being used during a module reprogramming event. 3. If the glowplug DTCs have set on a very low mileage vehicle (below 1000 miles) th ...
Controller Schematic Design
... Digital Supply Voltage has to be connected between VCC and GND pins. I connected pins 3, 5 and 21 to ground (GND). I connected pins 4 and 6 to VCC. The capacitor C1, which filters the digital supply voltage, is connected between VCC and GND. AVCC (Analog Supply Voltage) and AREF (Analog Reference) T ...
... Digital Supply Voltage has to be connected between VCC and GND pins. I connected pins 3, 5 and 21 to ground (GND). I connected pins 4 and 6 to VCC. The capacitor C1, which filters the digital supply voltage, is connected between VCC and GND. AVCC (Analog Supply Voltage) and AREF (Analog Reference) T ...
ISK 110 VESA
... motherboard user’s manual). Working on one connector at a time, use a very small flathead screwdriver or similar tool to lift up on the black tab located beside the gold posts (squares). This will allow you to easily slide out the pins from the USB plug. Working carefully so as not to damage the wir ...
... motherboard user’s manual). Working on one connector at a time, use a very small flathead screwdriver or similar tool to lift up on the black tab located beside the gold posts (squares). This will allow you to easily slide out the pins from the USB plug. Working carefully so as not to damage the wir ...
Technical Data Sheet
... ensure, that enough power filtering capacitors are provided in the system (470µF or more recommended per motor), in order to absorb mechanical energy fed back by the motor in stalling conditions. The power supply should be designed in a way, that it supplies the nominal motor voltage at the desired ...
... ensure, that enough power filtering capacitors are provided in the system (470µF or more recommended per motor), in order to absorb mechanical energy fed back by the motor in stalling conditions. The power supply should be designed in a way, that it supplies the nominal motor voltage at the desired ...
Shure SR110 User Guide
... The MONITOR OUTPUTSILINE LEVEL connectors consists of one three-pin professional male audio connector (7) and two standard VI in. three-circuit (stereo) phone jacks (6). These connectors provide three line level, 600-ohm, balanced outputs to power amplifiers or recording equipment. The MIX BUS Phono ...
... The MONITOR OUTPUTSILINE LEVEL connectors consists of one three-pin professional male audio connector (7) and two standard VI in. three-circuit (stereo) phone jacks (6). These connectors provide three line level, 600-ohm, balanced outputs to power amplifiers or recording equipment. The MIX BUS Phono ...
How to Construct a Cable for Garmin GPS receivers
... A note about supplying power to your GPS Some Garmin GPS receivers are capable of running off external power ranging up to +32VDC or more, whereas others can only accept a maximum of +8VDC. If your receiver can only accept 8 volts and you connect it directly to a car battery, you will damage your GP ...
... A note about supplying power to your GPS Some Garmin GPS receivers are capable of running off external power ranging up to +32VDC or more, whereas others can only accept a maximum of +8VDC. If your receiver can only accept 8 volts and you connect it directly to a car battery, you will damage your GP ...
Gender of connectors and fasteners
In electrical and mechanical trades and manufacturing, each half of a pair of mating connectors or fasteners is conventionally assigned the designation male or female. The ""female"" connector is generally a receptacle that receives and holds the ""male"" connector.The assignment is a direct analogy with genitalia and sexual intercourse; the part bearing one or more protrusions, or which fits inside the other, being designated male in contrast to the part containing the corresponding indentations, or fitting outside the other, being designated female. Extension of the analogy results in the verb to mate being used to describe the process of connecting two corresponding parts together.In some cases (notably electrical power connectors), the gender of connectors is selected according to rigid rules, to enforce a sense of one-way directionality (e.g. a flow of power from one device to another). This gender distinction is implemented to enhance safety or ensure proper functionality by preventing unsafe or non-functional configurations from being set up.In terms of mathematical graph theory, an electrical power distribution network made up of plugs and sockets is a directed tree, with the directionality arrows corresponding to the female-to-male transfer of electrical power through each mated connection. This is an example where male and female connectors have been deliberately designed and assigned to physically enforce a safe network topology.In other contexts, such as plumbing, one-way flow is not enforced through connector gender assignment. Flows through piping networks can be bidirectional, as in underground water distribution networks which have designed-in redundancy. In plumbing situations where one-way flow is desired, it is implemented through other means (e.g. gravity flow, one-way check valves), and not through male-female gender schemes.