DTC P0443 EVAPORATIVE EMISSION CONTROL SYSTEM
... Remove the EFI relay from the engine room R/B. Disconnect the V10 EVAP VSV connector. Measure the resistance according to the value(s) in the ...
... Remove the EFI relay from the engine room R/B. Disconnect the V10 EVAP VSV connector. Measure the resistance according to the value(s) in the ...
VATS Bypass Module - 3rd Brake Flasher Web Site
... 3. Where is the VATS pin on my PCM, how do I find it: The VATS signal wire will be labeled (in your vehicles service manual) as VATS, Fuel enable wire or circuit number 229 and is normally a dark blue wire. The pin number at the PCM varies depending on application: TBI/TPI 89-92 -------- pin# B6 (mi ...
... 3. Where is the VATS pin on my PCM, how do I find it: The VATS signal wire will be labeled (in your vehicles service manual) as VATS, Fuel enable wire or circuit number 229 and is normally a dark blue wire. The pin number at the PCM varies depending on application: TBI/TPI 89-92 -------- pin# B6 (mi ...
low voltage power module installation guide
... Connect the low voltage cables to the COMs and low voltage taps labeled on the Terminal blocks. Make sure that all connecting screws are secure and tight. REMEMBER!! Maximum 300W per circuit!! Turn off ALL the circuit breakers in the transformer unit. Plug the 120V line cord into a grounded 120V out ...
... Connect the low voltage cables to the COMs and low voltage taps labeled on the Terminal blocks. Make sure that all connecting screws are secure and tight. REMEMBER!! Maximum 300W per circuit!! Turn off ALL the circuit breakers in the transformer unit. Plug the 120V line cord into a grounded 120V out ...
Industrial Plugs and Sockets
... designed for application in the manufacturing and service industry, on building sites and similar uses. The main purpose of the standards is to prevent accidental or deliberate mismating of plugs and connections which are not compatible in terms of voltage, current, frequency, polarity and type of u ...
... designed for application in the manufacturing and service industry, on building sites and similar uses. The main purpose of the standards is to prevent accidental or deliberate mismating of plugs and connections which are not compatible in terms of voltage, current, frequency, polarity and type of u ...
Viola systems building blocks
... Serial cable for RS1 application port (Gateways) The RS1 application port is always RS-232 and switchable between the console and application (plain data) port. ...
... Serial cable for RS1 application port (Gateways) The RS1 application port is always RS-232 and switchable between the console and application (plain data) port. ...
Multi-Key v2.4 - Harbach Electronics
... center pin of the RADIO RCA phone jack on the Multi-Key should be connected the center pin of the keying/control jack of the transceiver. This is normally called TX-GND or GROUND-ON-TRANSMIT. Consult the operator’s manual for the proper connections. The outer ring (ground) of the RADIO RCA phono jac ...
... center pin of the RADIO RCA phone jack on the Multi-Key should be connected the center pin of the keying/control jack of the transceiver. This is normally called TX-GND or GROUND-ON-TRANSMIT. Consult the operator’s manual for the proper connections. The outer ring (ground) of the RADIO RCA phono jac ...
Temposonics®
... 1. The “(+) Stop” output is used for a compatible square wave neuter signal. 2. The G-Series output signal, “(-) Stop” is not used when providing the backwards-compatible neuter type connection. However, this signal wire/connector pin is used for “RS-422 TX-” during serial programming of the sensor. ...
... 1. The “(+) Stop” output is used for a compatible square wave neuter signal. 2. The G-Series output signal, “(-) Stop” is not used when providing the backwards-compatible neuter type connection. However, this signal wire/connector pin is used for “RS-422 TX-” during serial programming of the sensor. ...
SHDSL Power Feeding Hub
... connection with the said warranties are satisfactory. Software components in the PFH-4 are provided "as is" and without warranty of any kind. RAD disclaims all warranties including the implied warranties of merchantability and fitness for a particular purpose. RAD shall not be liable for any loss of ...
... connection with the said warranties are satisfactory. Software components in the PFH-4 are provided "as is" and without warranty of any kind. RAD disclaims all warranties including the implied warranties of merchantability and fitness for a particular purpose. RAD shall not be liable for any loss of ...
AN-34 - Pumpkin, Inc.
... A JFPC adapter from Softbaugh, Inc.3 is used to convert the FPC connector to the standard 2x7 JTAG MSP430 header. The JFPC adapter is pinned out as an internal power adapter. The FM430 Flight Module + JFPC adapter combination results in an internal power JTAG connector (VCC on pin 2, with pin 4 disc ...
... A JFPC adapter from Softbaugh, Inc.3 is used to convert the FPC connector to the standard 2x7 JTAG MSP430 header. The JFPC adapter is pinned out as an internal power adapter. The FM430 Flight Module + JFPC adapter combination results in an internal power JTAG connector (VCC on pin 2, with pin 4 disc ...
MRMS Installation Instructions
... BACnet wiring suggest using a 22 AWG stranded wire in a shielded cable, B+,A-, Gnd and shield should be run. This can be 2 twisted pairs with a separate cable shield. One twisted pair is used for communications, the second twisted pair can be used for communications ground and the shield wire can be ...
... BACnet wiring suggest using a 22 AWG stranded wire in a shielded cable, B+,A-, Gnd and shield should be run. This can be 2 twisted pairs with a separate cable shield. One twisted pair is used for communications, the second twisted pair can be used for communications ground and the shield wire can be ...
CONSUMMATE PHONO STAGE - Jeff Rowland Design Group
... professional technician, or to order these interconnects through a cable company.) The simplest form would be an extension of the existing tonearm wires. For each channel, we recommend that these wires be 28 AWG or smaller diameter; use either solid core high purity copper, stranded or solid core pu ...
... professional technician, or to order these interconnects through a cable company.) The simplest form would be an extension of the existing tonearm wires. For each channel, we recommend that these wires be 28 AWG or smaller diameter; use either solid core high purity copper, stranded or solid core pu ...
UM-35CL NEMA 4-20mA Process Loop 3 1/2 DIGIT with 0.56” or 0.8” LEDs
... Texmate’s exclusive optional Push-On Connectors combine an edge card connector and a 10 position screw terminal block. Push-On Connectors are ordered preconfigured for each specific power supply voltage and each optional power supply available for the UM-Series. Pinouts are marked on Connector ...
... Texmate’s exclusive optional Push-On Connectors combine an edge card connector and a 10 position screw terminal block. Push-On Connectors are ordered preconfigured for each specific power supply voltage and each optional power supply available for the UM-Series. Pinouts are marked on Connector ...
Installation Guide, Serial Interface T942SI, TD90927gb.fm
... System and System 5000. T942SI is designed to communicate with the external unit via an interface of type RS232C, RS422, or RS485. The interfaces are galvanically isolated for up to 500 V. All the inputs and outputs have transient protection, and all bus connections are equipped with chokes for incr ...
... System and System 5000. T942SI is designed to communicate with the external unit via an interface of type RS232C, RS422, or RS485. The interfaces are galvanically isolated for up to 500 V. All the inputs and outputs have transient protection, and all bus connections are equipped with chokes for incr ...
USER MANUAL VU01 Hukseflux
... VU01 is a high-quality ventilation unit for use with pyranometer model SR20 and pyrgeometer models IR20 and IR20WS. Its purpose is to improve the dependability of the measurement. Measurement accuracy improves because offsets are reduced. Reliability benefits from prevention of dew and frost formati ...
... VU01 is a high-quality ventilation unit for use with pyranometer model SR20 and pyrgeometer models IR20 and IR20WS. Its purpose is to improve the dependability of the measurement. Measurement accuracy improves because offsets are reduced. Reliability benefits from prevention of dew and frost formati ...
Hardware Design Guide
... The ballast transistor requires capacitors to be added for decoupling and stability. The number of capacitors is not important — only the overall capacitance value and the overall ESR value are important. • C1 – The capacitance on VDD_LV is determined by the stability requirement of the regulator. I ...
... The ballast transistor requires capacitors to be added for decoupling and stability. The number of capacitors is not important — only the overall capacitance value and the overall ESR value are important. • C1 – The capacitance on VDD_LV is determined by the stability requirement of the regulator. I ...
Stratomaster Enigma Stratomaster Odyssey
... instruments. These ground connections may not be designed to allow large current flows. In this example, should you press your PTT to start a transmission, a current of several amperes may flow through the signal grounds causing potential damage. Enigma and Odyssey contain electronic components in t ...
... instruments. These ground connections may not be designed to allow large current flows. In this example, should you press your PTT to start a transmission, a current of several amperes may flow through the signal grounds causing potential damage. Enigma and Odyssey contain electronic components in t ...
Installation guide: Axis P7216
... This equipment has been designed and tested to fulfill applicable standards for: • Radio frequency emission when installed according to the instructions and used in its intended environment. • Immunity to electrical and electromagnetic phenomena when installed according to the instructions and used ...
... This equipment has been designed and tested to fulfill applicable standards for: • Radio frequency emission when installed according to the instructions and used in its intended environment. • Immunity to electrical and electromagnetic phenomena when installed according to the instructions and used ...
instructions installation of load-share terminals for vlt
... Note: The upper load-share terminals on the D1/D3 frame drives are located behind the capacitor bank. The gate-drive board and capacitor bank must be removed to gain access to the upper load share terminals. For D1/D3 Frames: Remove the gate-drive board mounting plate (and the gate drive board) by ...
... Note: The upper load-share terminals on the D1/D3 frame drives are located behind the capacitor bank. The gate-drive board and capacitor bank must be removed to gain access to the upper load share terminals. For D1/D3 Frames: Remove the gate-drive board mounting plate (and the gate drive board) by ...
Firewire 800 Fiber Optic Extender
... Optic Extender transmitter connects to the host computer with a standard cable, the receiver provides two ports for connection of peripheral devices. In addition, LEDs provide link performance status at a glance. One duplex fiber optic cable, available in different lengths from Thinklogical, connect ...
... Optic Extender transmitter connects to the host computer with a standard cable, the receiver provides two ports for connection of peripheral devices. In addition, LEDs provide link performance status at a glance. One duplex fiber optic cable, available in different lengths from Thinklogical, connect ...
UM1045
... CAN DB9 plug connector pinouts (CN400 and CN401) . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Ethernet RJ45 connector pinout (CN300). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 RS232/UART0 DB9 plug connector pinout (CN500) . . . . . . . . . . . . . . . . ...
... CAN DB9 plug connector pinouts (CN400 and CN401) . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Ethernet RJ45 connector pinout (CN300). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 RS232/UART0 DB9 plug connector pinout (CN500) . . . . . . . . . . . . . . . . ...
point2point
... instruments (they have a metal case that is directly connected to earth via the power supply cable). When operating the equipment note the following: ...
... instruments (they have a metal case that is directly connected to earth via the power supply cable). When operating the equipment note the following: ...
DIY ECU Checker Box (200SX CA18DET S13)
... DIY ECU Checker Box (200SX CA18DET S13) ECU Self Diagnosis? There’s just got to be an easier way to pull error codes from the ECU other that removing the kick panel and the ECU itself. The FSM document showed a possibility with a checker-box that can be connected to a check-connector that’s located ...
... DIY ECU Checker Box (200SX CA18DET S13) ECU Self Diagnosis? There’s just got to be an easier way to pull error codes from the ECU other that removing the kick panel and the ECU itself. The FSM document showed a possibility with a checker-box that can be connected to a check-connector that’s located ...
ETI Research Tellurium Copper Bullet Plugs data
... The ETI BulletPlug® solves these problems by providing a faster, cleaner signal of high purity and detail. To achieve this we have designed the BulletPlug® as a miniature cable — with high-conductive, gold-plated tellurium copper (CuTe) pins—as our standard product—providing rapid transfer of electr ...
... The ETI BulletPlug® solves these problems by providing a faster, cleaner signal of high purity and detail. To achieve this we have designed the BulletPlug® as a miniature cable — with high-conductive, gold-plated tellurium copper (CuTe) pins—as our standard product—providing rapid transfer of electr ...
Installation and Maintenance Sheet - IF 1315 Revision 2
... and interlocked ARKTITE receptacle, a wiring pattern must be established for your system. Locations having different voltages, frequencies or types of current (AC or DC) MUST NOT have interchangeable attachment plugs as stated in paragraph 406.4(6)(F) of the National Electrical Code. 2. Connect grou ...
... and interlocked ARKTITE receptacle, a wiring pattern must be established for your system. Locations having different voltages, frequencies or types of current (AC or DC) MUST NOT have interchangeable attachment plugs as stated in paragraph 406.4(6)(F) of the National Electrical Code. 2. Connect grou ...
Gender of connectors and fasteners
In electrical and mechanical trades and manufacturing, each half of a pair of mating connectors or fasteners is conventionally assigned the designation male or female. The ""female"" connector is generally a receptacle that receives and holds the ""male"" connector.The assignment is a direct analogy with genitalia and sexual intercourse; the part bearing one or more protrusions, or which fits inside the other, being designated male in contrast to the part containing the corresponding indentations, or fitting outside the other, being designated female. Extension of the analogy results in the verb to mate being used to describe the process of connecting two corresponding parts together.In some cases (notably electrical power connectors), the gender of connectors is selected according to rigid rules, to enforce a sense of one-way directionality (e.g. a flow of power from one device to another). This gender distinction is implemented to enhance safety or ensure proper functionality by preventing unsafe or non-functional configurations from being set up.In terms of mathematical graph theory, an electrical power distribution network made up of plugs and sockets is a directed tree, with the directionality arrows corresponding to the female-to-male transfer of electrical power through each mated connection. This is an example where male and female connectors have been deliberately designed and assigned to physically enforce a safe network topology.In other contexts, such as plumbing, one-way flow is not enforced through connector gender assignment. Flows through piping networks can be bidirectional, as in underground water distribution networks which have designed-in redundancy. In plumbing situations where one-way flow is desired, it is implemented through other means (e.g. gravity flow, one-way check valves), and not through male-female gender schemes.