• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Changes in the 2005 National Electric code
Changes in the 2005 National Electric code

... signs may be Listed when shipped with subassemblies, installation instructions, and marking which indicate the need for field inspection of connections made in the field. 600.8 Enclosures. Live parts, other than lamps, and neon tubing shall be enclosed. Transformers and power supplies provided with ...
Ph.D Qualifying Exam February 16 , 2012
Ph.D Qualifying Exam February 16 , 2012

Analogical Modelling and Numerical Simulation of the Single
Analogical Modelling and Numerical Simulation of the Single

... The movement frequency of the mechanically driven rotor fα is more less than the voltage frequency u1(t): fα « fu1. For mutual inductances from equations (1) and (2), associated with Fig.1, it can easily establish the ...
MAX477 300MHz High-Speed Op Amp
MAX477 300MHz High-Speed Op Amp

... in the inverting or noninverting gain configurations (as with current-feedback amplifiers). However, be sure to select resistors that are small and noninductive. Surface-mount resistors are best for high-frequency circuits. Their material is similar to that of metal-film resistors, but to minimize i ...
DIP SWITCH ADJUSTMENT Multifunction timer ZMR , ZMRS, ZMRV
DIP SWITCH ADJUSTMENT Multifunction timer ZMR , ZMRS, ZMRV

Recall Last Lecture
Recall Last Lecture

... 1. Rout = RC = 6 k 2. Equation of vo : vo = -  ib RC = - 720 ib 3. Calculate Rib  using KVL: ib r + ie RE - vb = 0 but ie = (1+ ) ib = 121 ib so: ib [ 121(0.6) + 7.46 ] = vb  Rib = 80.06 k 4. Calculate Ri  RTH||Rib = 33.53 k 5. vb in terms of vs  use voltage divider: vb = [ Ri / ( Ri + Rs ...
SN754410 Quadruple Half-H Driver (Rev. C)
SN754410 Quadruple Half-H Driver (Rev. C)

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

RGB LED Cube
RGB LED Cube

TPS76801-Q1 数据资料 dataSheet 下载
TPS76801-Q1 数据资料 dataSheet 下载

... Peak output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally limited Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See dissipation rating tab ...
Digital Control of Permanent Magnet Synchronous Motors
Digital Control of Permanent Magnet Synchronous Motors

... generated and controlled. Assuming that the torque is proportional to the current flowing through the stator coils, the control of torque is equivalent to the control of the input current. The most outer control loop is the speed control loop. Mostly mechanical angular position sensors provide the r ...
surge suppressor fires
surge suppressor fires

... the disk through the Zinc Oxide to the opposing conductor. Typically this causes no occurrence, however when excessive voltage or repeated spikes are experienced, the MOV can fail. Failure occurs in one of three ways: 1) Conductors inside the MOV weld together forming a short circuit. This action sh ...
Title (Example: design and simulation of a full adder)
Title (Example: design and simulation of a full adder)

docx - Energy Rating
docx - Energy Rating

... type and dry-type distribution transformers, both single and three phase:  with power ratings between 10 and 2500 KVA;  with a system highest voltage of 24 kV; and  that are designed for 11 or 22kV networks. This covers transformers installed both in public and privately owned electrical distribu ...
AP1513
AP1513

... transient characteristics. The PWM control circuit is able to vary the duty ratio linearly from 0 up to 100%. This converter also contains an error amplifier circuit as well as a soft-start circuit that prevents overshoot at startup. An enable function, an over current protect function and a short c ...
PS25451 EPIC QFN sensor, non-contact, high gain Datasheet
PS25451 EPIC QFN sensor, non-contact, high gain Datasheet

... can be used to detect field disturbance due to the movement of a near-by object. This functionality can be employed in a range of applications including security motion sensors and non-contact electric switches for lighting, door opening, toys etc The device uses active feedback techniques to both l ...
battery temperature sensor
battery temperature sensor

Series 70 ePODs: Type-N - LayerZero Power Systems, Inc
Series 70 ePODs: Type-N - LayerZero Power Systems, Inc

... from the power electronics and control electronics sections, so that maintenance on a section can be safely performed. If maintenance is required on a particular section, power can be bypassed to another section to allow for safe repairs to be made. All connections are optically isolated to minimize ...
Dual Schottky Barrier Diode, 30 V, 2.0 A
Dual Schottky Barrier Diode, 30 V, 2.0 A

... grant any guarantee thereof. If you should intend to use our products for new introduction or other application different from current conditions on the usage of automotive device, communication device, office equipment, industrial equipment etc. , please consult with us about usage condition (tempe ...
DATA  SHEET BZA800A-series Quadruple ESD transient voltage suppressor
DATA SHEET BZA800A-series Quadruple ESD transient voltage suppressor

... Suitability for use ⎯ NXP Semiconductors products are not designed, authorized or warranted to be suitable for use in medical, military, aircraft, space or life support equipment, nor in applications where failure or malfunction of an NXP Semiconductors product can reasonably be expected to result i ...
Synchronous Buck Converter with Programmable Output
Synchronous Buck Converter with Programmable Output

... generating load dependant frequencies that are typically seen with lightly loaded switching regulators. ...
Measurements of Electric and Magnetic Fields Due to the Operation
Measurements of Electric and Magnetic Fields Due to the Operation

... In cities where many buildings are in close proximity to each other, the load density is high. Therefore, indoor power distribution substations, which usually have high nominal power, are located in the basement or the ground floor of buildings. It is easy to find such rooms in buildings. However, w ...
single phase energy meter
single phase energy meter

... Single phase dynamometer type power factor meter consists of a fixed coil which is split into two parts which carries a current of test circuit. Two identical pressure coils are pivoted on spindle of the moving system. One pressure coil has a resistance in series and other has an inductance in serie ...
For predictive maintenance, grab a 5 kV tester
For predictive maintenance, grab a 5 kV tester

... allow you to test the insulation in medium voltage equipment. Even if you aren’t regularly testing MV gear, these megohmmeters have test features that are worth a closer look. The principle of operation of IRTs is as basic as Ohm’s Law: V=IR or R=V/I. The tester generates a known dc voltage (250 V, ...
Product news - Danielson Europe
Product news - Danielson Europe

... The UMT-H has been extended with 7 additional rated currents and is now offered with a total of 24 rated currents, which cover the rated currents between 160 mA and 30 A. The compact SMD fuse stands out with its high breaking capacity. With its square, compact design, it is the space saving alternat ...
< 1 ... 1122 1123 1124 1125 1126 1127 1128 1129 1130 ... 2014 >

Alternating current



Alternating current (AC), is an electric current in which the flow of electric charge periodically reverses direction, whereas in direct current (DC, also dc), the flow of electric charge is only in one direction. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.AC is the form in which electric power is delivered to businesses and residences. The usual waveform of alternating current in most electric power circuits is a sine wave. In certain applications, different waveforms are used, such as triangular or square waves. Audio and radio signals carried on electrical wires are also examples of alternating current. These types of alternating current carry information encoded (or modulated) onto the AC signal, such as sound (audio) or images (video).
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report