• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
LABORATORY SESSION 6
LABORATORY SESSION 6

... rheostat and a pushbutton switch to the 120 V dc source. Connect the 120 V resistor bank in series with a dc ammeter across the armature and use a dc voltmeter to measure the terminal voltage. Zero the dynamometer scale. The ac ammeter is provided with a bypass toggle switch, press the switch to rea ...
QM2327232733
QM2327232733

... the dc-link voltage the reference value. It uses deviation of the capacitor voltage from its reference value as its input. However, the transient response of the conventional PI dc-link voltage controller is slow. In this paper, a fast-acting dc-link voltage controller based on the energy of a dc-li ...
5. Output Voltage Trimming
5. Output Voltage Trimming

BDTIC www.BDTIC.com/infineon  RF & Protection Devices
BDTIC www.BDTIC.com/infineon RF & Protection Devices

... PRIMECELL™, REALVIEW™, THUMB™, µVision™ of ARM Limited, UK. AUTOSAR™ is licensed by AUTOSAR development partnership. Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. COLOSSUS™, FirstGPS™ of Trimble Navigation Ltd. EMV™ of EMVCo, LLC (Visa Holdings Inc.). EPCOS™ of Epcos AG. FLEXGO™ of Microso ...
A New Cost Effective Sensorless Commutation
A New Cost Effective Sensorless Commutation

... estimated commutation signals are extracted directly from the specific average line to line voltage of a BLDCM using simple single-stage low pass filters and low cost comparators. ...
SEMI F47
SEMI F47

All about EMI filters - TDK
All about EMI filters - TDK

... itself. The DMN current flows along one ac conductor and returns along the other. No DMN current flows in the ground conductor. DMN can be suppressed using X-capacitors—within an EMI filter—connected between the power lines (line and neutral) and act as highFig. 2. This insertion-loss plot shows the ...
VT4 instructions rev2.indd
VT4 instructions rev2.indd

All about EMI filters - Digi
All about EMI filters - Digi

... itself. The DMN current flows along one ac conductor and returns along the other. No DMN current flows in the ground conductor. DMN can be suppressed using X-capacitors—within an EMI filter—connected between the power lines (line and neutral) and act as highFig. 2. This insertion-loss plot shows the ...
Voltage Harmonics Measuring Issues in Medium Voltage
Voltage Harmonics Measuring Issues in Medium Voltage

Si and InGaAs Low-Light Analog APD Receiver Modules
Si and InGaAs Low-Light Analog APD Receiver Modules

... a 50 Ω termination. The module must not be DC-coupled to loads of less than 2 kΩ. For field use, it is recommended that a temperature-compensated HV supply be employed to maintain a constant responsivity over temperature. Excelitas’ InGaAs LLAM-1060E and -1550E Preamplifier Modules, are designed to ...
INA125 数据资料 dataSheet 下载
INA125 数据资料 dataSheet 下载

... The stability and temperature drift of the external gain setting resistor, RG, also affects gain. RG’s contribution to gain accuracy and drift can be directly inferred from the gain equation (1). Low resistor values required for high gain can make wiring resistance important. Sockets add to the wiri ...
Medical Power Conditioning Presentation
Medical Power Conditioning Presentation

... Frequency changes occur on generators, but under some conditions can result from utility operation. They represent cycle to cycle changes from the fundamental 60 or 50 Hz. supply. ...
BDTIC
BDTIC

... Blockdiagram of a universal Ku-Band LNB .......................................................................................... 5 Specified Frequencies for LNB (Ku-Band) ........................................................................................... 6 The serial resistance Rs causes a ...
Application Note - Atmel Corporation
Application Note - Atmel Corporation

NCL30051LEDGEVB - 35-50 Volt, Up to 1.5 Amp, Offline
NCL30051LEDGEVB - 35-50 Volt, Up to 1.5 Amp, Offline

... fewer LEDs to be used to achieve the same light output. For example, the Cree XLAMP XM−L is rated for up to 3 A drive current and has a very low typical forward voltage of 3.1 V @ 1500 mA drive current. At 1500 mA and 85°C junction temperature, in cool white, each LED generates from 440−475 lumens t ...
Demonstrations in Ultrasound Imaging and Beam Steering Using
Demonstrations in Ultrasound Imaging and Beam Steering Using

Analog Devices Welcomes Hittite Microwave Corporation www.analog.com www.hittite.com
Analog Devices Welcomes Hittite Microwave Corporation www.analog.com www.hittite.com

... [1] Pin is not connected internally, however, pin must be connected to GND to maintain product family pin for pin compatibility. [2] BIAS ref voltage (pin 20) cannot drive an external load, and must be measured with a 10 GOhm meter such as Agilent 34410A; a typical 10 Mohm DVM will read erroneously. ...
Scaling Analysis of On-Chip Power Grid Voltage
Scaling Analysis of On-Chip Power Grid Voltage

... Note that the resistive voltage drop derived in (2) is the worst-case scenario since the current sources Ii’s are dependent on the magnitude of Vi+1’s (Figure 3). For calculating the actual voltage drop, one must use the nonlinear voltage-dependent current source by using Ids of the switching device ...
Analog Devices Welcomes Hittite Microwave Corporation
Analog Devices Welcomes Hittite Microwave Corporation

Maintaining Voltage-Current Phase Relationships in Power Quality
Maintaining Voltage-Current Phase Relationships in Power Quality

Control of Transient Power during Unintentional Islanding of
Control of Transient Power during Unintentional Islanding of

... seamlessly [11]. During grid-connected mode, the frequency is stiff and maintained by the power grid. Hence, the power set-point of the droop controller can be used to control the power output of the inverter. This power set-point can be adjusted by an energy management system implemented inside the ...
Aalborg Universitet
Aalborg Universitet

... In [3], a parametric study on these systems shows the dependency of power losses on the droop parameters, thus it makes sense to consider as part of the solution of the OPF also the set of droop parameters affecting the power injection from grid forming units. In the problem, the other variables are ...
Return Loss
Return Loss

HT-5500 - Ono Sokki Technologies
HT-5500 - Ono Sokki Technologies

... used under correct operating conditions according to descriptions in this manual and notices on the unit label. 3. For free-of-charge repair during the warranty period, contact your dealer or your nearest Ono Sokki sales office ...
< 1 ... 85 86 87 88 89 90 91 92 93 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.