• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
docx
docx

WECC Solar PV Dynamic Model Specification
WECC Solar PV Dynamic Model Specification

USER GUIDE
USER GUIDE

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... the power transfer capability of a line, as thermal limits permit, while maintaining the same degree of stability [3]-[9]. Numerous recent applications of FACTS have proven to be cost-effective, long-term solutions. With the improvements in current and voltage handling capabilities of the power elec ...
Noise - Massachusetts Institute of Technology
Noise - Massachusetts Institute of Technology

HMC364S8G/E
HMC364S8G/E

ISO Rules Part 500 Facilities Division 502 Technical Requirements
ISO Rules Part 500 Facilities Division 502 Technical Requirements

... lack of correlation was caused by equipment problems for the generating unit that the legal owner corrected prior to the revalidation testing date. Model Validation and Reactive Power Verification Reporting 12(1) The legal owner of a generating unit must submit all test results referred to in this s ...
G - Iowa State University
G - Iowa State University

... voltage solutions. The upper one corresponds to one that can be reached in practice. The lower one is correct mathematically, but I do not know of a way to reach these points in practice. 4. In the lagging or unity power factor condition, it is clear that the voltage decreases as the load power incr ...
Aalborg Universitet Generations
Aalborg Universitet Generations

... of load is supported only by DG1 with VCM at 1.58kW. At t1, the DG2 starts, and the VCM and CCM unit are able to share the active loads at 800W. At t2, the second CCM unit DG3 starts, and all DG units share the total active load evenly. It can be seen that the active power can be shared well due to ...
the overview brochure - Kniel System
the overview brochure - Kniel System

... sophisticated service – Kniel power supplies set standards. For your success. Founded in 1975 by Helmut Kniel, the company has been pursuing a clear concept right from the very start: specialisation. By focussing on power supplies, in conjunction with one hundred percent in-house production, the com ...
to the manual (MEC-manual-UK)
to the manual (MEC-manual-UK)

... The MEC-50 is meant for pre amplifier and driver stages while the MEC100 is designed for small class A SE amplifiers with the 300B or 2A3 or EL84 power valves as examples. Small push-pull power amplifiers with maximum current demand below 100 mA are also possible, like 2 x EL84 or 2 x ECL86. For cur ...
Scaling properties of a non-Fowler–Nordheim tunnelling junction
Scaling properties of a non-Fowler–Nordheim tunnelling junction

15P0161B1 - DCREG for Applications to Electromagnets
15P0161B1 - DCREG for Applications to Electromagnets

... DCREG4 thyristor converter can be used to power very inductive loads, such as electromagnets. Applications problems due to this type of load - that can be compared to a ohmic resistance series-connected to a very strong inductance - have been solved by a control algorithm specially developed for DCR ...
i DEVELOPMENT OF A POWER FACTOR CORRECTION BUCK
i DEVELOPMENT OF A POWER FACTOR CORRECTION BUCK

A Grid Current-Controlling Shunt Active Power Filter
A Grid Current-Controlling Shunt Active Power Filter

Document
Document

Chapter 7 - UniMAP Portal
Chapter 7 - UniMAP Portal

SED1335F - Electrical and Information Technology
SED1335F - Electrical and Information Technology

... The SED1335F is a graphics and character display controller for use with medium scale dot matrix LCDs. The SED1335F generates all the signals required by the display memory and LCD drivers, and incorporates a character generator ROM, so that flexible, low power, display systems can be designed with ...
MF10-P1/MF10-P2 - hegewald
MF10-P1/MF10-P2 - hegewald

... · Do not use the product in environments subject to flammable or explosive gases. · To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices. · Do not use the product in any atmosphere or environment that exceeds the ratings. · Do ...
RF3705 数据资料DataSheet下载
RF3705 数据资料DataSheet下载

... RF input internally matched to 50  and DC blocked. The RF input matching circuit has a shunt inductor to ground which would short any DC voltage placed on this pin. No connection. No connection. Digital control input for PA enable and disable (see Operating Modes truth table). Coupler output. This ...
Waveforms and definitions class notes
Waveforms and definitions class notes

... Using the power concept, it is easy to reason that the following waveforms would all produce the same average power to a resistor, and thus their rms values are identical and equal to the previous example ...
Aalborg Universitet Parallel Inverters in Islanded Microgrids
Aalborg Universitet Parallel Inverters in Islanded Microgrids

... present the inherent drawback of needing to calculate instantaneous active and reactive powers, thus needing for low-pass filters to average values which bandwidth will impact the system transient response [16]. Even in the case of three-phase systems that the active and reactive power can be calcul ...
PQ3100 Power Quality Analyzer Complete Catalog
PQ3100 Power Quality Analyzer Complete Catalog

... 23°C ±5°C, 80% RH or less Warmup time: 30 m or more Power supply frequency range: 50 Hz/60 Hz ±2 Hz Defined for power factor of 1, common-mode voltage of 0 V, and after zero-adjustment. The following additional conditions apply for AC measurement: Input of at least 10 Vrms to reference channel ( ...
(MAV) Medical Automated Vitals System
(MAV) Medical Automated Vitals System

... Texas Instruments Mentor (if applicable): Date: Qty. ...
Instrument Condenser - TRIUS
Instrument Condenser - TRIUS

... Drums: The F90 is designed to clip on the rim of a drum, to a drum suspension system, and on some types of stands. The position of the F90 should be 2-3” off the drum head. It is not necessary or desirable to place the microphone too close to the drumhead. Miking more than one drum with one mic: The ...
< 1 ... 83 84 85 86 87 88 89 90 91 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report