• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
pwsp2
pwsp2

Kepco Product Guide
Kepco Product Guide

... instrumentation type power supplies. Tables are included for their programming characteristics (analog and digital), their physical characteristics, electrical output characteristics plus output power and voltage ranges. The purpose is to help you select an appropriate power supply for your applicat ...
Measurements and Performance Factor Comparisons
Measurements and Performance Factor Comparisons

LT5521 - Very High Linearity Active Mixer.
LT5521 - Very High Linearity Active Mixer.

... Low LO Leakage: –42dBm Integrated LO Buffer: Low LO Drive Level Single-Ended LO Drive Wide Single Supply Range: 3.15V to 5.25V ...
Driving apparatus and method of three phase induction motor
Driving apparatus and method of three phase induction motor

4200 Series LaserSource User's Manual
4200 Series LaserSource User's Manual

... have been designed to work well with the LaserSource. If using your own cables, ensure they have been properly wired according to the pin-out of the LaserSource and your fixture. Finally, set the set point to an appropriate current and press the Output button. The output will turn on and you will se ...
Current Sharing with Power Supplies | CUI Inc
Current Sharing with Power Supplies | CUI Inc

... Preventing Back-Driving Of Paralleled Power Supplies When the output terminals of multiple power supplies are connected in parallel it is possible one of the units may drive current into the output of other power supplies. In many instances this will be harmless and thus not an issue. However, with ...
- National Grid
- National Grid

Three Phase Circuit Analysis
Three Phase Circuit Analysis

... transmitted in the form of three-phase power except at the lowest voltage levels of the distribution system where single phase power is used. There are two main reasons for using three-phase power. First, the instantaneous power supplied to motors is constant torque and therefore motors run much smo ...
CC2541 - Texas Instruments
CC2541 - Texas Instruments

... Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to absol ...
DI23661665
DI23661665

... fuel cell inverters is given in [9] and [17]. This letter presents a multi string multilevel inverter for DERs application. The multi string inverter shown in Fig. 1 is a further development of the string inverter, whereby several strings are interfaced with their own dc/dc converter to a common inv ...
Stage Buddy - SM Pro Audio
Stage Buddy - SM Pro Audio

... Stage Buddy functions: GROUP MONITORING 100s of Stage Buddies can be used together, in a large orchestra, for example, with each player having independent control over their own volume, mix, and effects. Up to 20 Remote units can be daisy-chained on a single audio stream from a Master unit (with fou ...
Here - Spellman High Voltage
Here - Spellman High Voltage

LT5511 - High Signal Level Upconverting Mixer.
LT5511 - High Signal Level Upconverting Mixer.

... Oscillator Signal. They can also be driven single-ended by connecting one to an RF ground through a DC blocking capacitor. For single-ended drive, use LO+ for the signal input, as this results in less interference from unwanted coupling of the LO signal to other pins. These pins are internally biase ...
ADA4841-1 数据手册DataSheet 下载
ADA4841-1 数据手册DataSheet 下载

Super Led F10
Super Led F10

INTRODUCING THE NEW MINI INVERTERS BY LIGHTALARMS
INTRODUCING THE NEW MINI INVERTERS BY LIGHTALARMS

AND8256/D Control of the Output Voltage Range in NCP1653
AND8256/D Control of the Output Voltage Range in NCP1653

... As shown in the data sheet, the following equation gives the maximum average power an NCP1653 driven PFC stage can provide the load with: ...
Our Catalog
Our Catalog

... 1.) N+1 Redundant-Expandable Inverter System: For applications where reliability and maintainability are paramount, the N+1 redundant system offers the most cost effective method of achieving redundancy and the ability to maintain the system while loads remain on line. All cards (except 12 Vdc) are ...
Comparison of the AC UPS and the DC UPS solutions for critical loads
Comparison of the AC UPS and the DC UPS solutions for critical loads

... construction, divided into three main groups: resistive loads, electronic loads and rotating loads. The characteristics of each group will be further described in this section. Resistive loads are mainly used for lighting and heating purpose. Examples of such loads are incandescent lamps, kettles an ...
EGN 3373 Week 12b – AC Power
EGN 3373 Week 12b – AC Power

... simply because this quantity is a sinusoid in both cases, and therefore its average value over one cycle will be zero. On the other hand, the average power for a resistor is the square of the cosine, the integral of which over one cycle is not zero; these results simply suggest that resistances diss ...
Variable Frequency Drive Field Installation
Variable Frequency Drive Field Installation

1 electrical theory
1 electrical theory

... Whole numbers are exactly what the term implies. These numbers don’t contain any fractions, decimals, or percentages. Another name for whole numbers is “integers.” ...
Voltage Collapse and Sympathy Trips 2014 OTS
Voltage Collapse and Sympathy Trips 2014 OTS

... turn, result in changes in the generator output. There will be an interaction between the system and rotor speed. • The term “equal area criteria” is used to describe the comparison of the area that represents the energy stored in the turbine generator during the acceleration period and the area tha ...
User Manual - Hong Kong University of Science and
User Manual - Hong Kong University of Science and

< 1 ... 84 85 86 87 88 89 90 91 92 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report