• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Document
Document

BAUR_violaTD_FINAL_english_TEXT
BAUR_violaTD_FINAL_english_TEXT

... produce a characteristic curve, the height and course of which allows for conclusions on the status. Trend analyses based on regular measurements over a long period are also helpful. Therefore, it is recommended to always carry out the diagnostics together to create comparison options while evaluati ...
Paper 3
Paper 3

M5400-PM - Panamax!
M5400-PM - Panamax!

... Visual Indication of Power Level Panamax’s patent pending AVM™ circuitry continuously monitors the incoming power as displayed on the digital voltmeter. In case of an under voltage or an over voltage, a flashing red lightning bolt will be displayed in the voltmeter, and power to the connected equipme ...
C7/C9 LED Retrofits Instructions
C7/C9 LED Retrofits Instructions

... Lighting  LED  lamp  is  about  2  Volt-­‐Amps  (VA).  In  designing  a  display,  this  figure  must  be   used  to  specify  wire  size,  connector  size,  breaker,  and  fuse  size.  The  good  news  is  that   the  power  consum ...
EE406 Course title: Power System Analysis
EE406 Course title: Power System Analysis

Measuring Temperature and Testing BASIC Stamp
Measuring Temperature and Testing BASIC Stamp

DC Motors
DC Motors

... Example Problem 3 For the figure below Ig = 25 30ºmA, the turns ratio is 4:1, and VLD = 600ºV. The transformer is ideal. Find: a. Load current b. Load impedance c. Generator voltage d. Real and Reactive load power ...
14PE6 An Effective Control Method for Quasi-Z
14PE6 An Effective Control Method for Quasi-Z

Power Quality Measurements
Power Quality Measurements

170M____
170M____

... Flush End Contact: Type 4B/-, 4BKN/-, 4G/-, 4GKN/Size ...
The new three-phase power supplies CP
The new three-phase power supplies CP

... The CP-T range of three-phase power supply units is the youngest member of ABB’s power supply family. In terms of design and functionality, the new range perfectly supplements the existing products and extends the range appropriately. The devices can be supplied with a threephase voltage as well as ...
measurement of resistance ratios
measurement of resistance ratios

INSTRUMENTS Convenient selection of
INSTRUMENTS Convenient selection of

... The RC-10 provides a convenient selection of standard resistor and capacitor values available either separately or in series or parallel RC combinations. The unit includes 36 resistors ranging in value from 15 Ohms to megaohms, and 18 capacitors from 100 picofarads to 0.22µf. Both resistors and capa ...
G2PW...10 Voltage monitoring in 3
G2PW...10 Voltage monitoring in 3

power net - CIRCUTOR
power net - CIRCUTOR

WLA- Load balancing unit - PT Sinar Elektrindo Perkasa
WLA- Load balancing unit - PT Sinar Elektrindo Perkasa

... proportional regulation of the nominal value for several generating sets in parallel can be effected. This balancer is often combined with the frequency control unit "FN 1" and the synchronizer unit "SY 1" for a fully automatic synchronization with load balancing. Output impulses for speed governor ...
RF Considerations for Amateur Radio Data Links
RF Considerations for Amateur Radio Data Links

... More Definitions F is frequency in Hz, omega sub c is the carrier frequency in radians per second, c is the speed of light in meters /second. Psubt and Psub r must be in the same units, Gt and Gr are dimensionless. L is usually due to transmission line losses, filter losses, antenna losses, etc. L= ...
troubleshooting guide to power quality problems
troubleshooting guide to power quality problems

... that you hire a qualified electrician to determine if your existing electrical service is adequate to support your new air conditioner. For air conditioners larger than 12,000 BTU/H and below 36,000 BTU/H, you should have your electrician install a dedicated circuit for the unit. Please bear in mind ...
EESiFlo 6000 Specifications
EESiFlo 6000 Specifications

... During 8 years FlowRental.com has successfully rented the EESiFlo 6000 to hundreds of unique applications, and it has never failed to produce unequalled results. Our clients have measured pipes from ¼ inch all the way up to 200 inches in diameter. When you absolutely must make flow measurements unde ...
ECE 3144 Lecture 4
ECE 3144 Lecture 4

... – For a purely resistive impedance, P=VMIM/2 =I2MR/2=V2M/2R – For a purely reactive impedance, P= VMIMcos(90o)/2 =0, which means purely reactive impedances (such as a capacitor or an inductor) absorbs no average power. So they are also called lossless elements. They operate in a mode in which they s ...
Fluke 434/PWR Power Analyzer
Fluke 434/PWR Power Analyzer

Common Power Problems - A-TRAC
Common Power Problems - A-TRAC

... Ferrups protect against eight of the nine most common power problems. Extensive configurability and customization options make Ferrups the ideal power protection with a wide range of voltages, frequencies, runtimes, power cords and receptacles. These units provide power protection with ferroresonant ...
syllabus
syllabus

... Power Electronics is power conversion and control from one form of power (energy) source to a desired form by using power semiconductor devices wherein these devices operate as switches. This course provides a basic knowledge of power Electronics device characteristics and circuits for the control a ...
RIII Area Grid Operations - The United States Nuclear Infrastructure
RIII Area Grid Operations - The United States Nuclear Infrastructure

... Transmission system voltage is needed to transfer power from generation stations to the load centers Reactive power (VARs) is the component of total power that maintains voltages across the system Sufficient voltage is maintained by supplying the transmission system with reactive power from generati ...
< 1 ... 284 285 286 287 288 289 290 291 292 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report