• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Avo SR90 Specifications
Avo SR90 Specifications

Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a

... Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a unit or an aggregated generating facility, including those in a power plant or an industrial complex; or (b) the reactive power to be achieved by the generating unit, aggregated generating facility, power plant or industrial co ...
Unit 09 Instruments
Unit 09 Instruments

... The ohmmeter is used to measure resistance. There are two basic types: analog or digital. The common VOM (volt-ohm-milliammeter) contains an ohmmeter. An ohmmeter should always be readjusted to zero when the scale is changed. ...
CARVIN ENGINEERING DATA
CARVIN ENGINEERING DATA

... The TRx2115A is an active biamp multi purpose Main or Monitor enclosure. The compact trapezoidal design and 80x50 degree HF horn allows multiple cabinets to work together as array clusters. The 32 degree monitor tilt angle and 80 degree vertical HF dispersion provide powerful stage monitoring from 2 ...
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a

... R4 The ISO must establish exceptions for a generating unit or aggregated generating facility from complying with directives in requirements R5 and R8 which such exceptions are contained in Appendix 1 of this reliability standard. R4.1 The ISO must maintain a list of generating units and aggregated g ...
Reduced wiring system (CC-Link compliant SI unit) EX140
Reduced wiring system (CC-Link compliant SI unit) EX140

Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a
Alberta Reliability Standard Voltage and Reactive Control VAR-001-AB-1a

... MR4.1 Evidence of maintaining a list as required in requirement R4.1 exists. Evidence may include a posting of the required list on the AESO website. MR4.2 Evidence of notifying entities as required in requirement R4.2 exists. Evidence may include email or mail to appropriate recipient that identifi ...
Chapter 2 Interconnect Parasitic Extraction
Chapter 2 Interconnect Parasitic Extraction

AX8052 Power On Reset
AX8052 Power On Reset

RF EMF Strength Meter
RF EMF Strength Meter

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Compensation by reactive loading of existing transformers consist in the connection of reactors or capacitor banks to the tertiary (delta) winding of main existing transformers for voltage control purposes. Tertiary windings have voltage rating of the order of 11kv. As the reactors or capacitor bank ...
power transistors
power transistors

Hex high-to-low level shifter
Hex high-to-low level shifter

PRO SERIES manual
PRO SERIES manual

ELECTRONIC MEASUREMENTS AND INSTRUMENTATION
ELECTRONIC MEASUREMENTS AND INSTRUMENTATION

... A unit of measurement is a definite magnitude of a physical quantity, defined and adopted by convention and/or by law, that is used as a standard for measurement of the same physical quantity.[1] Any other value of the physical quantity can be expressed as a simple multiple of the unit of measuremen ...
Electrical Systems and Construction Student`s Book
Electrical Systems and Construction Student`s Book

Nuran Yörükeren Bora Alboyaci Ö.Özgür GENCER E.Mustafa
Nuran Yörükeren Bora Alboyaci Ö.Özgür GENCER E.Mustafa

... occurs mainly because most industries are in an endless race to upgrade their plants. In many cases, industries have their productivity indices, foreseen by projects, not achieved due mainly to PQ problems. Generally, this is caused by incompatibility between the power supply system and the operatio ...
LS 100 OWNERS MANUAL
LS 100 OWNERS MANUAL

... rear panel of DAC. Before using with a computer, you must install USB drivers (CD provided). PH button allows for inverting absolute phase. Some recordings are recorded out of phase and may sound better in phase-inverted mode. This will have to be determined by the listener and based on each recordi ...
Aerospace Amplifiers Products Embedded Technology
Aerospace Amplifiers Products Embedded Technology

... Voltage translator The NPT25190 and NPT25240 from Nitronex are 48 V GaN-on-silicon devices designed for WiMAX and 3G/3G LTE waveforms operating in frequency bands of 2.3 GHz to 2.7 GHz. Typical performance is rated using a mobile WiMAX waveform defined as a single-carrier OFDM signal 64 QAM ¾, 8 burs ...
CHAPTER-3 DSTATCOM
CHAPTER-3 DSTATCOM

The Simulation Study and Dynamic Analysis of Unified Power Flow
The Simulation Study and Dynamic Analysis of Unified Power Flow

Low Power Dual Operational Amplifier
Low Power Dual Operational Amplifier

p9 - VADA
p9 - VADA

... Cov  CGD0  W Cdj  C j  AD  C jsw  PD AD  W  D, PD  2(W  D ) ...
Intelligent_Industrial_Electronics
Intelligent_Industrial_Electronics

... AUTOMATION, CONTROLS AND PROTECTION INTELLIGENT INDUSTRIAL ELECTRONICS ...
single phase unified power flow controller without dc link
single phase unified power flow controller without dc link

< 1 ... 190 191 192 193 194 195 196 197 198 ... 316 >

Decibel

The decibel (dB) is a logarithmic unit that expresses the ratio of two values of a physical quantity, often power or intensity. One of these quantities is often a reference value and in this case the decibel expresses the absolute level of the physical quantity. The number of decibels is ten times the logarithm to base 10 of the ratio of two power quantities, or of the ratio of the squares of two field amplitude quantities. One decibel is one tenth of one bel, named in honor of Alexander Graham Bell; however, the bel is seldom used.The definition of the decibel is based on the measurement of power in telephony of the early 20th century in the Bell System in the United States. Today, the unit is used for a wide variety of measurements in science and engineering, most prominently in acoustics, electronics, and control theory. In electronics, the gains of amplifiers, attenuation of signals, and signal-to-noise ratios are often expressed in decibels. The decibel confers a number of advantages, such as the ability to conveniently represent very large or small numbers, and the ability to carry out multiplication of ratios by simple addition and subtraction. By contrast, use of the decibel complicates operations of addition and subtraction.A change in power by a factor of 10 is a 10 dB change. At the half power point an audio circuit or an antenna exhibits an attenuation of 3dB. A change in voltage by a factor of 10 results in a change in power by a factor of 100, which is a 20 dB change. A change in voltage ratio by a factor of two approximately corresponds to a 6 dB change.The decibel symbol is often qualified with a suffix that indicates the reference quantity that has been used or some other property of the quantity being measured. For example, dBm indicates a reference power of one milliwatt, while dBu is referenced to approximately 0.775 volts RMS.In the International System of Quantities, the decibel is defined as a unit of measurement for quantities of type level or level difference, which are defined as the logarithm of the ratio of power- or field-type quantities.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report